Difference between revisions of "Kecheng KC-330B"
Jump to navigation
Jump to search
Line 46: | Line 46: | ||
| 0x01 | | 0x01 | ||
| 0x81 | | 0x81 | ||
| Configure device, 6 bytes payload: | | '''Configure device''', 6 bytes payload: | ||
|- | |- | ||
Line 82: | Line 82: | ||
| 0x02 | | 0x02 | ||
| 0x82 | | 0x82 | ||
| Identify, response payload is length byte + device model (ASCII) | | '''Identify''', response payload is length byte + device model (ASCII) | ||
|- | |- | ||
| 0x03 | | 0x03 | ||
| 0x83 | | 0x83 | ||
| Set date and time, 6 bytes payload: | | '''Set date and time''', 6 bytes payload: | ||
|- | |- | ||
Line 122: | Line 122: | ||
|- | |- | ||
| 0x04 | | 0x04 | ||
| | |||
| '''Check status''' | |||
|- | |||
| | |||
| 0x84 | | 0x84 | ||
| | | | ||
|- | |||
| | |||
| 0xa4 | |||
| | |||
|- | |- | ||
| 0x05 | | 0x05 | ||
| 0x85 | | 0x85 | ||
| Get stored measurement info, response has 8 bytes payload: | | '''Get stored measurement info''', response has 8 bytes payload: | ||
|- | |- | ||
Line 148: | Line 156: | ||
| 0x06 | | 0x06 | ||
| 0x86 | | 0x86 | ||
| Get stored start date/time. Response has 6 bytes payload, same format as 0x03 command. | | '''Get stored start date/time'''. Response has 6 bytes payload, same format as 0x03 command. | ||
|- | |- | ||
| 0x07 | | 0x07 | ||
| 0x87 | | 0x87 | ||
| Get stored measurements, 3 bytes payload: | | '''Get stored measurements''', 3 bytes payload: | ||
|- | |- | ||
| | | | ||
Line 176: | Line 184: | ||
| 0x08 | | 0x08 | ||
| 0x88 | | 0x88 | ||
| Get live measurement, response has 2 bytes payload: big-endian integer representing the dB value X 10 | | '''Get live measurement''', response has 2 bytes payload: big-endian integer representing the dB value X 10 | ||
|} | |} |
Revision as of 09:40, 18 June 2013
Status | in progress |
---|---|
Connectivity | USB |
Measurement range (A) | 30dB - 130dB |
Resolution | 0.1dB |
Accuracy (94dB@1kHz) | 1.5dB |
Frequency weighting | A, C |
Time weighting | F, S |
The Kecheng KC-330B is a sound level meter and data logger with USB connectivity.
See Kecheng KC-330B/Info for more details (such as lsusb -vvv output) about the device.
Hardware
- Silicon Labs F320 8-bit MCU with USB interface
- 2 X SG Micro SGM8522 dual rail-to-rail op-amp, SGM8524 quad rail-to-rail op-amp
- Microchip 24LC512 64KB EEPROM
- Texas Instruments CD4053M triple 2-channel multiplexer
Photos
Protocol
The host sends commands to the device via endpoint 2, and receives responses via endpoint 1. A command consists of a single byte, with the MSB (bit 7) cleared, followed by any arguments to the command. The response from the device consists of at least one byte: the command, with the MSB set.
Command | Response | Description | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0x01 | 0x81 | Configure device, 6 bytes payload: | ||||||||||||||||||
| ||||||||||||||||||||
0x02 | 0x82 | Identify, response payload is length byte + device model (ASCII) | ||||||||||||||||||
0x03 | 0x83 | Set date and time, 6 bytes payload: | ||||||||||||||||||
| ||||||||||||||||||||
0x04 | Check status | |||||||||||||||||||
0x84 | ||||||||||||||||||||
0xa4 | ||||||||||||||||||||
0x05 | 0x85 | Get stored measurement info, response has 8 bytes payload: | ||||||||||||||||||
| ||||||||||||||||||||
0x06 | 0x86 | Get stored start date/time. Response has 6 bytes payload, same format as 0x03 command. | ||||||||||||||||||
0x07 | 0x87 | Get stored measurements, 3 bytes payload: | ||||||||||||||||||
| ||||||||||||||||||||
0x08 | 0x88 | Get live measurement, response has 2 bytes payload: big-endian integer representing the dB value X 10 |