Difference between revisions of "Philips PM2800 series"

From sigrok
Jump to navigation Jump to search
 
(3 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{Infobox power supply
{{Infobox power supply
| image              = [[File:Philips PM2813.png|180px]]
| image              = [[File:Philips PM2813.png|180px]]
| name                = Philips PM2813
| name                = Philips PM2800 series
| status              = planned
| status              = supported
| source_code_dir    = scpi-pps
| source_code_dir    = scpi-pps
| channels            = 1-3
| channels            = 1-3
Line 32: Line 32:
|}
|}


The autoranging modules go in chassis models 2811/2812/2813 (last digit is number of models), linear in models 2831/2832.
The autoranging modules go in chassis models 2811/2812/2813 (last digit is number of modules), linear in models 2831/2832.


These power supplies have also been sold under the Fluke brand.
These power supplies have also been sold under the Fluke brand.
Line 48: Line 48:
* [http://media.fluke.com/documents/pm2800xxumeng0300.pdf Users manual]
* [http://media.fluke.com/documents/pm2800xxumeng0300.pdf Users manual]
* [http://media.fluke.com/documents/pm2800xxrmeng0300.pdf Software reference manual]
* [http://media.fluke.com/documents/pm2800xxrmeng0300.pdf Software reference manual]
* [https://www.youtube.com/watch?v=UI0aVEko7ic EEVBlog video on the PM2812]


[[Category:Device]]
[[Category:Device]]
[[Category:Power supply]]
[[Category:Power supply]]
[[Category:Planned]]
[[Category:Supported]]

Latest revision as of 17:30, 21 June 2015

Philips PM2800 series
Philips PM2813.png
Status supported
Source code scpi-pps
Channels 1-3
Connectivity GPIB
Website fluke.com

The Philips PM2800 are a series of programmable power supplies with 1-3 output channels and GPIB connectivity. Each channel contains 1 of 6 available modules:

Voltage Current Power Type
30V 10A 60W autoranging
60V 5A 60W autoranging
60V 10A 120W autoranging
8V ±15A 120W linear
60V ±2A 120W linear
120V ±1A 120W linear

The autoranging modules go in chassis models 2811/2812/2813 (last digit is number of modules), linear in models 2831/2832.

These power supplies have also been sold under the Fluke brand.