Difference between revisions of "Loto OSCxxx series"
Jump to navigation
Jump to search
Uwe Hermann (talk | contribs) m |
Martinloren (talk | contribs) (→Devices: Added OSCH02) |
||
(16 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{Infobox oscilloscope | {{Infobox oscilloscope | ||
| image = | | image = | ||
| name = Loto | | name = Loto OSCxxx series | ||
| status = planned | | status = planned | ||
| source_code_dir = | | source_code_dir = | ||
Line 14: | Line 14: | ||
| connectivity = USB host and device | | connectivity = USB host and device | ||
| features = math: + / — / x / FFT / Digital decoder | | features = math: + / — / x / FFT / Digital decoder | ||
| website = [http:// | | website = [http://www.rockemb.com/index.php?m=content&c=index&a=lists&catid=96 rockemb.com] | ||
}} | }} | ||
The '''Loto | The '''Loto OSCxxx series''' are compact and portable digital storage oscilloscopes, produced by Rocktech. | ||
== Devices == | == Devices == | ||
{| class=" | {| class="alternategrey sigroktable" | ||
!Model || Bandwidth (MHz) || Sample Rate (MS/s by ch) || USB VID/PID | !Model || Bandwidth (MHz) || Sample Rate (MS/s by ch) || USB VID/PID || Notes | ||
|- | |- | ||
|| Loto | || Loto OSCH02 || 100 || 250 || 0x8312:0x8a2a || Rel. 2020 (250MSa just CH-A) | ||
|- | |- | ||
|| Loto | || Loto OSC2002 || 50 || 200 || 0x8312:0x8801 || 2018-2019 edition | ||
|- | |- | ||
|| Loto | || Loto OSCA02 || 35 || 100 || 0x8312:0x8a02 || | ||
|- | |- | ||
|| Loto | || [[Loto OSC802]] || 25 || 80 || 0x8312:0x8312 || | ||
|- | |- | ||
|| Loto OSCE02 || 50 || 200 || 0x8312:0x8101 | || Loto OSC482 || 20 || 50 || 0x8102:0x8102 || | ||
|- | |||
|| Loto BM102 || 20 || 50 || 0x8102:0x8102 || out of production | |||
|- | |||
|| Loto OSCE02 || 50 || 200 || 0x8312:0x8101 || | |||
|- | |- | ||
|} | |} | ||
Line 38: | Line 42: | ||
== Protocol == | == Protocol == | ||
=== OSC802 === | |||
Commands sent via Control Transfer to EP0. Samples buffer available on Bulk EP. List of commands (provisional): | |||
{| border="0" width="95%" style="font-size: smaller" class="alternategrey sigroktable" | |||
|- | |||
! style="width: 3em;" | Request Type | |||
! style="width: 3em;" | Request | |||
! style="width: 3em;" | Value | |||
! style="width: 3em;" | Index | |||
! style="width: 3em;" | Data | |||
! Description | |||
''' | |- | ||
| 0x80 | |||
| 0x33 | |||
| 0x00 | |||
| 0x00 | |||
| 1 byte | |||
| ''Start acquisition.'' | |||
|- | |||
| 0x80 | |||
| 0x50 | |||
| 0x00 | |||
| 0x00 | |||
| 1 byte | |||
| ''Check if acquisition buffer is ready. Write 0x21 in the data byte if ready.'' | |||
|- | |||
| 0x80 | |||
| 0x94 | |||
| value | |||
| 0x00 | |||
| 1 byte | |||
| ''Set sampling rate with value[0-3] and AC/DC for Channel 1 with value[4].'' | |||
''Rate values: 80MSa/s (B0000), 10MSa/s (B1000), 625KSa/s (B1100)'' | |||
''value[4] = 1 -> DC coupling, value[4] = 0 -> AC coupling'' | |||
|- | |||
| 0x80 | |||
| 0x22 0x23 0x24 | |||
| value | |||
| 0x00 | |||
| 1 byte | |||
| ''Set Channel 1 and Channel 2 voltage. Set AC/DC for Channel 2.'' | |||
|- | |||
| 0x80 | |||
| 0xE7 | |||
| value | |||
| 0x00 | |||
| 1 byte | |||
| ''Enable (value=1) or disable (value=0) hardware trigger on Channel 1.'' | |||
|- | |||
| 0x80 | |||
| 0xC5 | |||
| value | |||
| 0x00 | |||
| 1 byte | |||
| ''Set trigger slope up (value=1) or down (value=0).'' | |||
|- | |||
| 0x80 | |||
| 0x16 | |||
| value | |||
| 0x00 | |||
| 1 byte | |||
| ''Set trigger level (value=0-255).'' | |||
|} | |||
== Resources == | == Resources == | ||
* [http://www.rockemb.com/index.php?m=content&c=index&a=lists&catid=96 Vendor website] | |||
* [http://bbs.lotoins.com/ Forum] | |||
[[Category:Device]] | [[Category:Device]] | ||
[[Category:Oscilloscope]] | [[Category:Oscilloscope]] | ||
[[Category:Planned]] | [[Category:Planned]] |
Latest revision as of 10:44, 27 June 2020
Status | planned |
---|---|
Channels | 2 analog (all models) + trigger |
Samplerate | 50-200 MSa/s (by channel in dual channel) |
Samplerate (eq. time) | 0.2-1 GSa/s (dual channel combined or single channel) |
Analog bandwidth | 20-50 MHz (depending on model) |
Vertical resolution | 8bits |
Triggers | edge, pulse width, slope, video, alternate |
Input impedance | 1MΩ‖25pF±5pF |
Memory | 64Kpts (by channel, 128K total) |
Connectivity | USB host and device |
Features | math: + / — / x / FFT / Digital decoder |
Website | rockemb.com |
The Loto OSCxxx series are compact and portable digital storage oscilloscopes, produced by Rocktech.
Devices
Model | Bandwidth (MHz) | Sample Rate (MS/s by ch) | USB VID/PID | Notes |
---|---|---|---|---|
Loto OSCH02 | 100 | 250 | 0x8312:0x8a2a | Rel. 2020 (250MSa just CH-A) |
Loto OSC2002 | 50 | 200 | 0x8312:0x8801 | 2018-2019 edition |
Loto OSCA02 | 35 | 100 | 0x8312:0x8a02 | |
Loto OSC802 | 25 | 80 | 0x8312:0x8312 | |
Loto OSC482 | 20 | 50 | 0x8102:0x8102 | |
Loto BM102 | 20 | 50 | 0x8102:0x8102 | out of production |
Loto OSCE02 | 50 | 200 | 0x8312:0x8101 |
Protocol
OSC802
Commands sent via Control Transfer to EP0. Samples buffer available on Bulk EP. List of commands (provisional):
Request Type | Request | Value | Index | Data | Description |
---|---|---|---|---|---|
0x80 | 0x33 | 0x00 | 0x00 | 1 byte | Start acquisition. |
0x80 | 0x50 | 0x00 | 0x00 | 1 byte | Check if acquisition buffer is ready. Write 0x21 in the data byte if ready. |
0x80 | 0x94 | value | 0x00 | 1 byte | Set sampling rate with value[0-3] and AC/DC for Channel 1 with value[4].
Rate values: 80MSa/s (B0000), 10MSa/s (B1000), 625KSa/s (B1100) value[4] = 1 -> DC coupling, value[4] = 0 -> AC coupling |
0x80 | 0x22 0x23 0x24 | value | 0x00 | 1 byte | Set Channel 1 and Channel 2 voltage. Set AC/DC for Channel 2. |
0x80 | 0xE7 | value | 0x00 | 1 byte | Enable (value=1) or disable (value=0) hardware trigger on Channel 1. |
0x80 | 0xC5 | value | 0x00 | 1 byte | Set trigger slope up (value=1) or down (value=0). |
0x80 | 0x16 | value | 0x00 | 1 byte | Set trigger level (value=0-255). |