Difference between revisions of "Owon SDS series"
Jump to navigation
Jump to search
(Added SDS_Series_Oscilloscopes_SCPI_Protocol.pdf) |
(Added link to SDS_Series_Oscilloscopes_Service_Manual_v1_0.pdf) |
||
Line 55: | Line 55: | ||
*[https://bikealive.nl/tl_files/EmbeddedSystems/Test_Measurement/owon/OWON%20Oscilloscope%20PC%20Guidance%20Manual.pdf OWON Oscilloscope PC Guidance Manual v1.3.pdf] | *[https://bikealive.nl/tl_files/EmbeddedSystems/Test_Measurement/owon/OWON%20Oscilloscope%20PC%20Guidance%20Manual.pdf OWON Oscilloscope PC Guidance Manual v1.3.pdf] | ||
* [http://files.owon.com.cn/software/Application/SDS_Series_Oscilloscopes_SCPI_Protocol.pdf SDS_Series_Oscilloscopes_SCPI_Protocol.pdf] | * [http://files.owon.com.cn/software/Application/SDS_Series_Oscilloscopes_SCPI_Protocol.pdf SDS_Series_Oscilloscopes_SCPI_Protocol.pdf] | ||
* [https://www.mikrocontroller.net/attachment/126522/SDS_Series_Oscilloscopes_Service_Manual_v1_0.pdf SDS_Series_Oscilloscopes_Service_Manual_v1_0.pdf] | |||
[[Category:Device]] | [[Category:Device]] | ||
[[Category:Oscilloscope]] | [[Category:Oscilloscope]] | ||
[[Category:Planned]] | [[Category:Planned]] |
Latest revision as of 17:30, 26 April 2019
Status | planned |
---|---|
Channels | 2 analog (all models) + trigger |
Samplerate | 0.25-1.6 GSa/s (by channel in dual channel) |
Samplerate (eq. time) | 0.5-3.2 GSa/s (dual channel combined or single channel) |
Analog bandwidth | 60-300 MHz (depending on model) |
Vertical resolution | 8bits |
Triggers | edge, pulse width, slope, video, alternate |
Input impedance | 1MΩ‖10pF±5pF |
Memory | 10Mpts (by channel, 20M total) except on max samplerate of 8102,8202,8302 and 9302 models (10K) |
Display | 8" 800x600, 64K colors |
Connectivity | USB host and device, Ethernet, VGA, Trig pass/fail out |
Features | math: + / — / x / FFT ; Lithium battery |
Website | owon.com.hk |
The Owon SDS series are ... digital storage oscilloscopes.
Devices
Model | Bandwidth (MHz) | Sample Rate (GS/s by ch) | USB VID/PID |
---|---|---|---|
Owon SDS6062 | 60 | 0.5 | |
Owon SDS7072 | 70 | 1 | |
Owon SDS7102 | 100 | 1 | 5345:1234 |
Owon SDS8102 | 100 | 2 | |
Owon SDS8202 | 200 | 2 | |
Owon SDS8302 | 300 | 2.5 | |
Owon SDS9302 | 300 | 3.2 |
Protocol
Simple text commands sent through USB or Ethernet, data is then sent back by bulk (header then data) for USB, or simple packets (Ethernet).
Some models seems to support SCPI (SDS7102 doesn't yet).
The menu items can be triggered by special commands.