The [http://www.hantek.com/english/produce_list.asp?unid=68 Hantek DDS-3X25] is | {{Infobox signal generator | ||
| image = [[File:Hantek DDS-3X25 top.jpg|180px]] | |||
| name = Hantek DDS-3X25 | |||
| status = planned | |||
| source_code_dir = | |||
| frequser = 25MHz | |||
| waveforms = user only | |||
| waveformmem = 4000 points | |||
| amplitude = 0 - 3.5V | |||
| connectivity = USB | |||
| website = [http://www.hantek.com/en/ProductDetail_12_24.html hantek.com] | |||
}} | |||
The [http://www.hantek.com/english/produce_list.asp?unid=68 Hantek DDS-3X25] is a 25MHz PC-based function generator. It has no external controls, requiring a USB connection to a computer. | |||
See [[Hantek DDS-3X25/Info]] for more details (such as lsusb -vvv output) about the device. | |||
== Hardware == | |||
* FPGA: Xylinx Spartan? 144 pins (20 MHz clock) | |||
* Microcontroller: STM32F103C6(T6A) Mainstream Performance line, ARM Cortex-M3 MCU with 32 Kbytes Flash, 72 MHz CPU, motor control, USB and CAN (8 MHz? clock) | |||
* Output amplifier: LMH6702 1.7 GHz, Ultra Low Distortion, Wideband Op Amp. | |||
* Sync signal output is connected without any buffer or amplifier. | |||
* COUNT IN is connected through TL3016 ULTRA-FAST LOW-POWER PRECISION COMPARATOR. | |||
* Isolated unregulated DC-DC converter MORNSUN A0505S-2W, ±5V, ±200mA | |||
== Photos == | == Photos == | ||
<gallery> | <gallery> | ||
Hantek DDS-3X25 bottom.jpg | |||
Hantek DDS-3X25 front.jpg | |||
Hantek DDS-3X25 back.jpg | |||
Hantek DDS-3X25 PCB top.png | |||
Hantek DDS-3X25 PCB bottom.png | |||
</gallery> | </gallery> | ||
== Protocol == | |||
==== Waveform samples ==== | |||
When sending a waveform to the device, a series of samples denote voltage. These are 12-bit values packed in padded 16-bit integers, sent in network order (most significant part first): | |||
* bits 0-9 are the value, with encoding as shown below | |||
* bit 10 | |||
* bit 11 is the sign: 1 for positive, 0 for negative | |||
* bit 12 controls the "sync out" port: 1 is on, 0 is off | |||
* bits 13 is always 1, bits 14-15 are always 0 | |||
The value is encoded as 2048 - (voltage * 585). Negative values have all sign and value bits complemented (reversed). | |||
==== 0xA0: configure ==== | |||
Configures the device. The payload is 6 bytes: | |||
{| border="0" width="95%" style="font-size: smaller" class="alternategrey sigroktable" | |||
|- | |||
! style="width: 3em;" | Byte | |||
! style="width: 3em;" | Bit | |||
! Description | |||
|- | |||
| 1 | |||
| | |||
| Mode | |||
|- | |||
| | |||
| 7 | |||
| | |||
|- | |||
| | |||
| 6 | |||
| | |||
|- | |||
| | |||
| 5 | |||
| 1 = Reset external trigger (send only once) | |||
|- | |||
| | |||
| 4 | |||
| 1 = External trigger mode enabled | |||
|- | |||
| | |||
| 3 | |||
| External trigger: 0 = falling, 1 = rising | |||
|- | |||
| | |||
| 2 | |||
| 0 = continuous, 1 = single wave | |||
|- | |||
| | |||
| 1 | |||
| Counter reset: 0 = leave, 1 = reset | |||
|- | |||
| | |||
| 0 | |||
| Measurement: 0 = frequency, 1 = counter | |||
|- | |||
| 2 | |||
| | |||
| | |||
|- | |||
| | |||
| 7 | |||
| | |||
|- | |||
| | |||
| 6 | |||
| | |||
|- | |||
| | |||
| 5 | |||
| | |||
|- | |||
| | |||
| 4 | |||
| | |||
|- | |||
| | |||
| 3 | |||
| | |||
|- | |||
| | |||
| 2 | |||
| | |||
|- | |||
| | |||
| 1 | |||
| | |||
|- | |||
| | |||
| 0 | |||
| Output: 0 = pattern generator, 1 = programmable output | |||
|- | |||
| 3 | |||
| | |||
| Digital I/O pins, bits 0-7 | |||
|- | |||
| 4 | |||
| | |||
| Bits 0-3 = digital I/O pins bits 8-11, bits 4-7 unused | |||
|- | |||
| 5 | |||
| | |||
| Clock divider, based on 48KHz clock | |||
|- | |||
| 6 | |||
| | |||
| | |||
|} | |||
THe response is 10 bytes: | |||
* the first 2 bytes are always 0 | |||
* in frequency measurement mode: | |||
** four bytes for the current frequency measurement, in network order. Multiply by 2 to get the actual frequency readout. | |||
** four bytes for a "tick counter" in network order. This has the number of ticks per second, and is used to derive the frequency. ''Assuming a 100Mhz clock, this counter differs up to 4.17% at 8Mhz from the derived frequency -- investigate.'' | |||
* in counter mode: | |||
** four bytes for the current counter, in network order. | |||
** four bytes denoting the smoothed out frequency, identical to the first four bytes in frequency measurement mode. | |||
==== 0xA1: point transfer indicator ==== | |||
The payload is 2 bytes: | |||
{| border="0" width="95%" style="font-size: smaller" class="alternategrey sigroktable" | |||
|- | |||
! style="width: 3em;" | Byte | |||
! style="width: 3em;" | Bit | |||
! Description | |||
|- | |||
| 1 | |||
| 0-7 | |||
| Bits 0-7 of the waveform point count | |||
|- | |||
| 2 | |||
| 0-3 | |||
| Bits 8-11 of the waveform point count | |||
|- | |||
| | |||
| 4-6 | |||
| Unused | |||
|- | |||
| | |||
| 7 | |||
| 0=transfer end, 1=transfer start | |||
|} | |||
There is a 1-byte response: 0xcc | |||
==== 0xA2: unknown ==== | |||
* 6-byte payload: 0000 0000 3000 | |||
* 1-byte response: 0xcd | |||
When setting "close output power on", i.e. save configuration to memory: | |||
* no payload | |||
* 1-byte response: 0xcd | |||
==== 0xA3: unknown ==== | |||
* no payload | |||
* 1-byte response: 0x02 | |||
== Resources == | |||
* [https://bitbucket.org/kuzavas/dds3x25/src Hantek DDS-3X25 access library written in Python] (incomplete) | |||
* [http://www.soasystem.com/eng/goltek/synch.htm Hantek DDS-3X25 In-Synch (In-Phase) Signal] | |||
* [http://www.soasystem.com/eng/goltek/phaprop.htm Hantek DDS-3X25 Phase Profile Concept and File Format] | |||
[[Category:Device]] | |||
[[Category:Signal generator]] | |||
[[Category:Frequency counter]] | |||
[[Category:Planned]] |
Latest revision as of 01:00, 7 March 2017
Status | planned |
---|---|
Frequency (user) | 25MHz |
Waveforms | user only |
Waveform memory | 4000 points |
Amplitude | 0 - 3.5V |
Connectivity | USB |
Website | hantek.com |
The Hantek DDS-3X25 is a 25MHz PC-based function generator. It has no external controls, requiring a USB connection to a computer.
See Hantek DDS-3X25/Info for more details (such as lsusb -vvv output) about the device.
Hardware
- FPGA: Xylinx Spartan? 144 pins (20 MHz clock)
- Microcontroller: STM32F103C6(T6A) Mainstream Performance line, ARM Cortex-M3 MCU with 32 Kbytes Flash, 72 MHz CPU, motor control, USB and CAN (8 MHz? clock)
- Output amplifier: LMH6702 1.7 GHz, Ultra Low Distortion, Wideband Op Amp.
- Sync signal output is connected without any buffer or amplifier.
- COUNT IN is connected through TL3016 ULTRA-FAST LOW-POWER PRECISION COMPARATOR.
- Isolated unregulated DC-DC converter MORNSUN A0505S-2W, ±5V, ±200mA
Photos
Protocol
Waveform samples
When sending a waveform to the device, a series of samples denote voltage. These are 12-bit values packed in padded 16-bit integers, sent in network order (most significant part first):
- bits 0-9 are the value, with encoding as shown below
- bit 10
- bit 11 is the sign: 1 for positive, 0 for negative
- bit 12 controls the "sync out" port: 1 is on, 0 is off
- bits 13 is always 1, bits 14-15 are always 0
The value is encoded as 2048 - (voltage * 585). Negative values have all sign and value bits complemented (reversed).
0xA0: configure
Configures the device. The payload is 6 bytes:
Byte | Bit | Description |
---|---|---|
1 | Mode | |
7 | ||
6 | ||
5 | 1 = Reset external trigger (send only once) | |
4 | 1 = External trigger mode enabled | |
3 | External trigger: 0 = falling, 1 = rising | |
2 | 0 = continuous, 1 = single wave | |
1 | Counter reset: 0 = leave, 1 = reset | |
0 | Measurement: 0 = frequency, 1 = counter | |
2 | ||
7 | ||
6 | ||
5 | ||
4 | ||
3 | ||
2 | ||
1 | ||
0 | Output: 0 = pattern generator, 1 = programmable output | |
3 | Digital I/O pins, bits 0-7 | |
4 | Bits 0-3 = digital I/O pins bits 8-11, bits 4-7 unused | |
5 | Clock divider, based on 48KHz clock | |
6 |
THe response is 10 bytes:
- the first 2 bytes are always 0
- in frequency measurement mode:
- four bytes for the current frequency measurement, in network order. Multiply by 2 to get the actual frequency readout.
- four bytes for a "tick counter" in network order. This has the number of ticks per second, and is used to derive the frequency. Assuming a 100Mhz clock, this counter differs up to 4.17% at 8Mhz from the derived frequency -- investigate.
- in counter mode:
- four bytes for the current counter, in network order.
- four bytes denoting the smoothed out frequency, identical to the first four bytes in frequency measurement mode.
0xA1: point transfer indicator
The payload is 2 bytes:
Byte | Bit | Description |
---|---|---|
1 | 0-7 | Bits 0-7 of the waveform point count |
2 | 0-3 | Bits 8-11 of the waveform point count |
4-6 | Unused | |
7 | 0=transfer end, 1=transfer start |
There is a 1-byte response: 0xcc
0xA2: unknown
- 6-byte payload: 0000 0000 3000
- 1-byte response: 0xcd
When setting "close output power on", i.e. save configuration to memory:
- no payload
- 1-byte response: 0xcd
0xA3: unknown
- no payload
- 1-byte response: 0x02