Difference between revisions of "HYELEC MS8236"
Uwe Hermann (talk | contribs) |
|||
(2 intermediate revisions by the same user not shown) | |||
Line 55: | Line 55: | ||
'''Example''': In the protocol a byte of '''0x3F''' ('''0 0111111''') represents the digit '''9''' on the LCD, where the decimal point is '''not''' displayed (bit 7 is not set). All other bits except for bit 6 (segment A, see above) are set, i.e. the respective LCD segments are displayed. | '''Example''': In the protocol a byte of '''0x3F''' ('''0 0111111''') represents the digit '''9''' on the LCD, where the decimal point is '''not''' displayed (bit 7 is not set). All other bits except for bit 6 (segment A, see above) are set, i.e. the respective LCD segments are displayed. | ||
The meter have an NCV icon but the function is not documented on the manual, I wasn't able to trigger it, it's probably not implemented. | |||
Everything with a (?) after is doubtful or impossible to confirm. | |||
Protocol consists of 22 bytes: | |||
Bytes 1 to 6: Always AA 55 52 24 01 10 . Probably some kind of header to test if transmission is ok, as the protocol doesn't have any kind of CRC. | |||
Bytes 7 to 10: Next four bits are the big LCD numbers, from right to left, in the format already specified by uwe_ on the wiki. | |||
Byte 11: 00000000 -> Diode icon | |||
|||||||---> AC | |||
||||||----> DC | |||
|||||-----> - | |||
||||------> - (yeah, both bits set to 1 when displaying "minus") | |||
|||-------> "Progess bar cue" -the bar with the 0 - 10 - 20 - ... | |||
||--------> Continuity tester "sound" icon | |||
|---------> Battery | |||
Bytes 12 to 18: that "progress bar on the top". Dunno what's its use, probably we can ignore it | |||
Byte 19: 00000000 -> More progress bar thingy | |||
|||||||---> More progress bar thingy | |||
||||||----> More progress bar thingy | |||
|||||-----> More progress bar thingy | |||
||||------> Wait... (?) (Never shown on the PC but as it is a LCD protocol probably goes mapped here internally even if it never get transmited to the PC) | |||
|||-------> Auto | |||
||--------> HOLD (?) (USB transmission seems to stop when Hold is activated) | |||
|---------> REL | |||
Byte 20: 00000000 -> USB Icon (Of course, always on) | |||
|||||||---> MAX | |||
||||||----> - (between MAX and MIN) | |||
|||||-----> MIN | |||
||||------> N/A (?) | |||
|||-------> % | |||
||--------> hFE | |||
|---------> N/A (?) | |||
Byte 21: 00000000 -> C | |||
|||||||---> F (temp) | |||
||||||----> N/A (?) | |||
|||||-----> N/A (?) | |||
||||------> m (in the Farads line) | |||
|||-------> u (in the Farads line) | |||
||--------> n (in the Farads line) | |||
|---------> F (Farads) | |||
Byte 22: 00000000 -> u (in the A line) | |||
|||||||---> m (in the A line) | |||
||||||----> A | |||
|||||-----> V (in diode meter mode) | |||
||||------> M (in the Ohms line) | |||
|||-------> k (in the Ohms line) | |||
||--------> Ohms | |||
|---------> Hz | |||
== Resources == | == Resources == |
Latest revision as of 22:03, 15 October 2015
Status | planned |
---|---|
Counts | 6000 |
IEC 61010-1 | CAT III (1000V) / CAT IV (600V) |
Connectivity | USB |
Measurements | voltage, resistance, diode, capacitance, frequency, current, hFE, temperature |
Features | autorange, true-rms, data hold, delay hold, min/max, relative, bargraph, backlight |
Website | hy-elec.com |
The HYELEC MS8236 is a 6000 counts, CAT III (1000V) / CAT IV (600V) handheld digital multimeter with USB connectivity.
See HYELEC MS8236/Info for more details (such as lsusb -v output) about the device.
Hardware
- 8-bit MCU with 4x40 LCD driver and 18-bit ADC: Hycontek HY11P14 (datasheet, user's guide)
- USB to serial IC: WCN CH340G (datasheet)
Photos
Multimeter:
USB cable:
Standard USB to miniUSB.
Protocol
TODO.
The device's LCD segments are layed out as follows:
G | ||
C | F | |
B | ||
A | E | |
D |
To the left of each LCD digit there is another segment which represents a dot / decimal point (DP).
An LCD segment is represented in the protocol as follows:
Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 |
---|---|---|---|---|---|---|---|
DP | A | B | C | D | E | F | G |
Example: In the protocol a byte of 0x3F (0 0111111) represents the digit 9 on the LCD, where the decimal point is not displayed (bit 7 is not set). All other bits except for bit 6 (segment A, see above) are set, i.e. the respective LCD segments are displayed.
The meter have an NCV icon but the function is not documented on the manual, I wasn't able to trigger it, it's probably not implemented. Everything with a (?) after is doubtful or impossible to confirm.
Protocol consists of 22 bytes:
Bytes 1 to 6: Always AA 55 52 24 01 10 . Probably some kind of header to test if transmission is ok, as the protocol doesn't have any kind of CRC.
Bytes 7 to 10: Next four bits are the big LCD numbers, from right to left, in the format already specified by uwe_ on the wiki.
Byte 11: 00000000 -> Diode icon
|||||||---> AC ||||||----> DC |||||-----> - ||||------> - (yeah, both bits set to 1 when displaying "minus") |||-------> "Progess bar cue" -the bar with the 0 - 10 - 20 - ... ||--------> Continuity tester "sound" icon |---------> Battery
Bytes 12 to 18: that "progress bar on the top". Dunno what's its use, probably we can ignore it
Byte 19: 00000000 -> More progress bar thingy
|||||||---> More progress bar thingy ||||||----> More progress bar thingy |||||-----> More progress bar thingy ||||------> Wait... (?) (Never shown on the PC but as it is a LCD protocol probably goes mapped here internally even if it never get transmited to the PC) |||-------> Auto ||--------> HOLD (?) (USB transmission seems to stop when Hold is activated) |---------> REL
Byte 20: 00000000 -> USB Icon (Of course, always on)
|||||||---> MAX ||||||----> - (between MAX and MIN) |||||-----> MIN ||||------> N/A (?) |||-------> % ||--------> hFE |---------> N/A (?)
Byte 21: 00000000 -> C
|||||||---> F (temp) ||||||----> N/A (?) |||||-----> N/A (?) ||||------> m (in the Farads line) |||-------> u (in the Farads line) ||--------> n (in the Farads line) |---------> F (Farads)
Byte 22: 00000000 -> u (in the A line)
|||||||---> m (in the A line) ||||||----> A |||||-----> V (in diode meter mode) ||||------> M (in the Ohms line) |||-------> k (in the Ohms line) ||--------> Ohms |---------> Hz