Difference between revisions of "Philips PM2800 series"
Jump to navigation
Jump to search
(5 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{Infobox power supply | {{Infobox power supply | ||
| image = [[File:Philips PM2813.png|180px]] | | image = [[File:Philips PM2813.png|180px]] | ||
| name = Philips | | name = Philips PM2800 series | ||
| status = | | status = supported | ||
| source_code_dir = scpi-pps | | source_code_dir = scpi-pps | ||
| channels = 1-3 | | channels = 1-3 | ||
Line 32: | Line 32: | ||
|} | |} | ||
The autoranging modules go in chassis models 2811/2812/2813 (last digit is number of | The autoranging modules go in chassis models 2811/2812/2813 (last digit is number of modules), linear in models 2831/2832. | ||
These power supplies have also been sold under the Fluke brand. | These power supplies have also been sold under the Fluke brand. | ||
Line 40: | Line 40: | ||
<gallery> | <gallery> | ||
File:Philips PM2813 back.jpg|<small>Back of PM2813/111</small> | File:Philips PM2813 back.jpg|<small>Back of PM2813/111</small> | ||
File:Philips PM2813 control.jpg|<small>PM2813/111 control board</small> | |||
</gallery> | </gallery> | ||
Line 47: | Line 48: | ||
* [http://media.fluke.com/documents/pm2800xxumeng0300.pdf Users manual] | * [http://media.fluke.com/documents/pm2800xxumeng0300.pdf Users manual] | ||
* [http://media.fluke.com/documents/pm2800xxrmeng0300.pdf Software reference manual] | * [http://media.fluke.com/documents/pm2800xxrmeng0300.pdf Software reference manual] | ||
* [https://www.youtube.com/watch?v=UI0aVEko7ic EEVBlog video on the PM2812] | |||
[[Category:Device]] | [[Category:Device]] | ||
[[Category:Power supply]] | [[Category:Power supply]] | ||
[[Category: | [[Category:Supported]] |
Latest revision as of 17:30, 21 June 2015
Status | supported |
---|---|
Source code | scpi-pps |
Channels | 1-3 |
Connectivity | GPIB |
Website | fluke.com |
The Philips PM2800 are a series of programmable power supplies with 1-3 output channels and GPIB connectivity. Each channel contains 1 of 6 available modules:
Voltage | Current | Power | Type |
---|---|---|---|
30V | 10A | 60W | autoranging |
60V | 5A | 60W | autoranging |
60V | 10A | 120W | autoranging |
8V | ±15A | 120W | linear |
60V | ±2A | 120W | linear |
120V | ±1A | 120W | linear |
The autoranging modules go in chassis models 2811/2812/2813 (last digit is number of modules), linear in models 2831/2832.