]> sigrok.org Git - sigrok-test.git/blobdiff - decoder/test/modbus/test.conf
modbus: Add a wizmodbus test-case.
[sigrok-test.git] / decoder / test / modbus / test.conf
index 51e420dd10c33b98be888d0690f0bf92334c324a..2964abf8e18e66442030b69b161e07f278577c5c 100644 (file)
@@ -1,6 +1,55 @@
 test brainchild_io_16do
        protocol-decoder uart channel rx=0 channel tx=1 option baudrate=19200 option invert_rx=yes option invert_tx=yes option parity_type=even
-       protocol-decoder modbus option scchannel=RX
+       protocol-decoder modbus option scchannel=RX option cschannel=TX
        stack uart modbus
        input uart/modbus_rtu/brainchild_io_16do/brainchild-io-16do.sr
        output modbus annotation match brainchild_io_16do.output
+
+test flowmeter_graph_tool
+       protocol-decoder uart channel rx=2 option baudrate=9600
+       protocol-decoder modbus option scchannel=RX option cschannel=RX
+       stack uart modbus
+       input uart/modbus_rtu/flowmeter/flowmeter_graph_tool.sr
+       output modbus annotation match flowmeter_graph_tool.output
+
+test flowmeter_target0_val0
+       protocol-decoder uart channel rx=2 option baudrate=9600
+       protocol-decoder modbus option scchannel=RX option cschannel=RX
+       stack uart modbus
+       input uart/modbus_rtu/flowmeter/flowmeter_graph_tool.sr
+       output modbus annotation match flowmeter_graph_tool.output
+
+test flowmeter_target_0liter_per_min
+       protocol-decoder uart channel rx=2 option baudrate=9600
+       protocol-decoder modbus option scchannel=RX option cschannel=RX
+       stack uart modbus
+       input uart/modbus_rtu/flowmeter/flowmeter_target_0liter_per_min.sr
+       output modbus annotation match flowmeter_target_0liter_per_min.output
+
+test flowmeter_target_15liter_per_min
+       protocol-decoder uart channel rx=2 option baudrate=9600
+       protocol-decoder modbus option scchannel=RX option cschannel=RX
+       stack uart modbus
+       input uart/modbus_rtu/flowmeter/flowmeter_target_15liter_per_min.sr
+       output modbus annotation match flowmeter_target_15liter_per_min.output
+
+test flowmeter_target_20liter_per_min
+       protocol-decoder uart channel rx=2 option baudrate=9600
+       protocol-decoder modbus option scchannel=RX option cschannel=RX
+       stack uart modbus
+       input uart/modbus_rtu/flowmeter/flowmeter_target_20liter_per_min.sr
+       output modbus annotation match flowmeter_target_20liter_per_min.output
+
+test wizmodbus
+       protocol-decoder uart channel rx=0 channel tx=3 option baudrate=9600
+       protocol-decoder modbus option scchannel=TX option cschannel=RX
+       stack uart modbus
+       input uart/modbus_rtu/wizmodbus/wizmodbus.sr
+       output modbus annotation match wizmodbus.output
+
+test wizmodbus_bus
+       protocol-decoder uart channel rx=2 channel tx=2 option baudrate=9600
+       protocol-decoder modbus option scchannel=TX option cschannel=TX option framegap=0
+       stack uart modbus
+       input uart/modbus_rtu/wizmodbus/wizmodbus.sr
+       output modbus annotation match wizmodbus_bus.output