]>
Commit | Line | Data |
---|---|---|
1 | 3-32 spiflash: bit: "Unknown command: 0x3f" | |
2 | 28-49 spiflash: bit: "Unknown command: 0xff" | |
3 | 49-70 spiflash: bit: "Unknown command: 0xff" | |
4 | 69-92 spiflash: bit: "Unknown command: 0xff" | |
5 | 11243-11264 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
6 | 11268-11289 spiflash: field: "Manufacturer ID: 0xc2" | |
7 | 11289-11310 spiflash: field: "Memory type: 0x20" | |
8 | 11310-11329 spiflash: field: "Device ID: 0x15" | |
9 | 11243-11329 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
10 | 11331-11350 spiflash: bit: "Unknown command: 0xff" | |
11 | 61807-61828 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
12 | 61832-61853 spiflash: field: "Manufacturer ID: 0xc2" | |
13 | 61853-61872 spiflash: field: "Memory type: 0x20" | |
14 | 61874-61893 spiflash: field: "Device ID: 0x15" | |
15 | 61807-61893 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
16 | 61895-61914 spiflash: bit: "Unknown command: 0xff" | |
17 | 111908-111929 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
18 | 111933-111954 spiflash: field: "Manufacturer ID: 0xc2" | |
19 | 111954-111975 spiflash: field: "Memory type: 0x20" | |
20 | 111975-111996 spiflash: field: "Device ID: 0x15" | |
21 | 111908-111996 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
22 | 111996-112015 spiflash: bit: "Unknown command: 0xff" | |
23 | 160879-160900 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
24 | 160904-160925 spiflash: field: "Manufacturer ID: 0xc2" | |
25 | 160925-160944 spiflash: field: "Memory type: 0x20" | |
26 | 160946-160965 spiflash: field: "Device ID: 0x15" | |
27 | 160879-160965 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
28 | 160967-160986 spiflash: bit: "Unknown command: 0xff" | |
29 | 210825-210844 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
30 | 210850-210869 spiflash: field: "Manufacturer ID: 0xc2" | |
31 | 210870-210891 spiflash: field: "Memory type: 0x20" | |
32 | 210891-210912 spiflash: field: "Device ID: 0x15" | |
33 | 210825-210912 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
34 | 210912-210933 spiflash: bit: "Unknown command: 0xff" | |
35 | 261418-261439 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
36 | 261443-261464 spiflash: field: "Manufacturer ID: 0xc2" | |
37 | 261464-261485 spiflash: field: "Memory type: 0x20" | |
38 | 261485-261506 spiflash: field: "Device ID: 0x15" | |
39 | 261418-261506 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
40 | 261506-261525 spiflash: bit: "Unknown command: 0xff" | |
41 | 312970-312989 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
42 | 312995-313014 spiflash: field: "Manufacturer ID: 0xc2" | |
43 | 313016-313035 spiflash: field: "Memory type: 0x20" | |
44 | 313036-313057 spiflash: field: "Device ID: 0x15" | |
45 | 312970-313057 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
46 | 313057-313078 spiflash: bit: "Unknown command: 0xff" | |
47 | 362962-362981 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
48 | 362987-363006 spiflash: field: "Manufacturer ID: 0xc2" | |
49 | 363008-363027 spiflash: field: "Memory type: 0x20" | |
50 | 363029-363048 spiflash: field: "Device ID: 0x15" | |
51 | 362962-363048 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
52 | 363049-363070 spiflash: bit: "Unknown command: 0xff" | |
53 | 412961-412982 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
54 | 412986-413007 spiflash: field: "Manufacturer ID: 0xc2" | |
55 | 413007-413028 spiflash: field: "Memory type: 0x20" | |
56 | 413028-413047 spiflash: field: "Device ID: 0x15" | |
57 | 412961-413047 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
58 | 413049-413068 spiflash: bit: "Unknown command: 0xff" | |
59 | 462966-462985 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
60 | 462991-463010 spiflash: field: "Manufacturer ID: 0xc2" | |
61 | 463012-463031 spiflash: field: "Memory type: 0x20" | |
62 | 463033-463052 spiflash: field: "Device ID: 0x15" | |
63 | 462966-463052 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
64 | 463053-463074 spiflash: bit: "Unknown command: 0xff" | |
65 | 512947-512968 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
66 | 512972-512993 spiflash: field: "Manufacturer ID: 0xc2" | |
67 | 512993-513014 spiflash: field: "Memory type: 0x20" | |
68 | 513014-513033 spiflash: field: "Device ID: 0x15" | |
69 | 512947-513033 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
70 | 562937-562956 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
71 | 562962-562981 spiflash: field: "Manufacturer ID: 0xc2" | |
72 | 562983-563002 spiflash: field: "Memory type: 0x20" | |
73 | 563004-563023 spiflash: field: "Device ID: 0x15" | |
74 | 562937-563023 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
75 | 612937-612958 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
76 | 612962-612983 spiflash: field: "Manufacturer ID: 0xc2" | |
77 | 612983-613004 spiflash: field: "Memory type: 0x20" | |
78 | 613004-613025 spiflash: field: "Device ID: 0x15" | |
79 | 612937-613025 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
80 | 662929-662950 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
81 | 662954-662975 spiflash: field: "Manufacturer ID: 0xc2" | |
82 | 662975-662996 spiflash: field: "Memory type: 0x20" | |
83 | 662996-663015 spiflash: field: "Device ID: 0x15" | |
84 | 662929-663015 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
85 | 712919-712938 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
86 | 712944-712963 spiflash: field: "Manufacturer ID: 0xc2" | |
87 | 712964-712985 spiflash: field: "Memory type: 0x20" | |
88 | 712985-713006 spiflash: field: "Device ID: 0x15" | |
89 | 712919-713006 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
90 | 762532-762551 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
91 | 762557-762576 spiflash: field: "Manufacturer ID: 0xc2" | |
92 | 762577-762598 spiflash: field: "Memory type: 0x20" | |
93 | 762598-762619 spiflash: field: "Device ID: 0x15" | |
94 | 762532-762619 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
95 | 812914-812933 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
96 | 812939-812958 spiflash: field: "Manufacturer ID: 0xc2" | |
97 | 812960-812979 spiflash: field: "Memory type: 0x20" | |
98 | 812980-813001 spiflash: field: "Device ID: 0x15" | |
99 | 812914-813001 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
100 | 862913-862934 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
101 | 862938-862959 spiflash: field: "Manufacturer ID: 0xc2" | |
102 | 862959-862980 spiflash: field: "Memory type: 0x20" | |
103 | 862980-863001 spiflash: field: "Device ID: 0x15" | |
104 | 862913-863001 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
105 | 911848-911869 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
106 | 911873-911894 spiflash: field: "Manufacturer ID: 0xc2" | |
107 | 911894-911915 spiflash: field: "Memory type: 0x20" | |
108 | 911915-911934 spiflash: field: "Device ID: 0x15" | |
109 | 911848-911934 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
110 | 966518-966537 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
111 | 966543-966562 spiflash: field: "Manufacturer ID: 0xc2" | |
112 | 966564-966583 spiflash: field: "Memory type: 0x20" | |
113 | 966584-966605 spiflash: field: "Device ID: 0x15" | |
114 | 966518-966605 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
115 | 1012361-1012382 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
116 | 1012386-1012407 spiflash: field: "Manufacturer ID: 0xc2" | |
117 | 1012407-1012428 spiflash: field: "Memory type: 0x20" | |
118 | 1012428-1012447 spiflash: field: "Device ID: 0x15" | |
119 | 1012361-1012447 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
120 | 1062490-1062509 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
121 | 1062515-1062534 spiflash: field: "Manufacturer ID: 0xc2" | |
122 | 1062536-1062555 spiflash: field: "Memory type: 0x20" | |
123 | 1062556-1062577 spiflash: field: "Device ID: 0x15" | |
124 | 1062490-1062577 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
125 | 1112875-1112894 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
126 | 1112900-1112919 spiflash: field: "Manufacturer ID: 0xc2" | |
127 | 1112921-1112940 spiflash: field: "Memory type: 0x20" | |
128 | 1112942-1112961 spiflash: field: "Device ID: 0x15" | |
129 | 1112875-1112961 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
130 | 1165977-1165996 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
131 | 1166002-1166021 spiflash: field: "Manufacturer ID: 0xc2" | |
132 | 1166023-1166042 spiflash: field: "Memory type: 0x20" | |
133 | 1166044-1166063 spiflash: field: "Device ID: 0x15" | |
134 | 1165977-1166063 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
135 | 1212854-1212875 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
136 | 1212879-1212900 spiflash: field: "Manufacturer ID: 0xc2" | |
137 | 1212900-1212921 spiflash: field: "Memory type: 0x20" | |
138 | 1212921-1212940 spiflash: field: "Device ID: 0x15" | |
139 | 1212854-1212940 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
140 | 1262476-1262495 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
141 | 1262501-1262520 spiflash: field: "Manufacturer ID: 0xc2" | |
142 | 1262522-1262541 spiflash: field: "Memory type: 0x20" | |
143 | 1262543-1262562 spiflash: field: "Device ID: 0x15" | |
144 | 1262476-1262562 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
145 | 1316116-1316137 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
146 | 1316141-1316162 spiflash: field: "Manufacturer ID: 0xc2" | |
147 | 1316162-1316181 spiflash: field: "Memory type: 0x20" | |
148 | 1316183-1316202 spiflash: field: "Device ID: 0x15" | |
149 | 1316116-1316202 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
150 | 1365952-1365971 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
151 | 1365977-1365996 spiflash: field: "Manufacturer ID: 0xc2" | |
152 | 1365997-1366018 spiflash: field: "Memory type: 0x20" | |
153 | 1366018-1366039 spiflash: field: "Device ID: 0x15" | |
154 | 1365952-1366039 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
155 | 1412838-1412857 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
156 | 1412863-1412882 spiflash: field: "Manufacturer ID: 0xc2" | |
157 | 1412883-1412904 spiflash: field: "Memory type: 0x20" | |
158 | 1412904-1412925 spiflash: field: "Device ID: 0x15" | |
159 | 1412838-1412925 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
160 | 1462831-1462852 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
161 | 1462856-1462877 spiflash: field: "Manufacturer ID: 0xc2" | |
162 | 1462877-1462898 spiflash: field: "Memory type: 0x20" | |
163 | 1462898-1462919 spiflash: field: "Device ID: 0x15" | |
164 | 1462831-1462919 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
165 | 1542633-1542652 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
166 | 1542658-1542677 spiflash: field: "Manufacturer ID: 0xc2" | |
167 | 1542679-1542698 spiflash: field: "Memory type: 0x20" | |
168 | 1542700-1542719 spiflash: field: "Device ID: 0x15" | |
169 | 1542633-1542719 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
170 | 1564887-1564908 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
171 | 1564912-1564933 spiflash: field: "Manufacturer ID: 0xc2" | |
172 | 1564933-1564954 spiflash: field: "Memory type: 0x20" | |
173 | 1564954-1564975 spiflash: field: "Device ID: 0x15" | |
174 | 1564887-1564975 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
175 | 1615932-1615953 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
176 | 1615957-1615978 spiflash: field: "Manufacturer ID: 0xc2" | |
177 | 1615978-1615997 spiflash: field: "Memory type: 0x20" | |
178 | 1615999-1616018 spiflash: field: "Device ID: 0x15" | |
179 | 1615932-1616018 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
180 | 1662807-1662828 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
181 | 1662832-1662853 spiflash: field: "Manufacturer ID: 0xc2" | |
182 | 1662853-1662874 spiflash: field: "Memory type: 0x20" | |
183 | 1662874-1662893 spiflash: field: "Device ID: 0x15" | |
184 | 1662807-1662893 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
185 | 1713436-1713457 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
186 | 1713461-1713482 spiflash: field: "Manufacturer ID: 0xc2" | |
187 | 1713482-1713501 spiflash: field: "Memory type: 0x20" | |
188 | 1713503-1713522 spiflash: field: "Device ID: 0x15" | |
189 | 1713436-1713522 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
190 | 1766409-1766430 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
191 | 1766434-1766455 spiflash: field: "Manufacturer ID: 0xc2" | |
192 | 1766455-1766474 spiflash: field: "Memory type: 0x20" | |
193 | 1766476-1766495 spiflash: field: "Device ID: 0x15" | |
194 | 1766409-1766495 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
195 | 1812777-1812798 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
196 | 1812802-1812823 spiflash: field: "Manufacturer ID: 0xc2" | |
197 | 1812823-1812844 spiflash: field: "Memory type: 0x20" | |
198 | 1812844-1812863 spiflash: field: "Device ID: 0x15" | |
199 | 1812777-1812863 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
200 | 1862253-1862272 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
201 | 1862278-1862297 spiflash: field: "Manufacturer ID: 0xc2" | |
202 | 1862299-1862318 spiflash: field: "Memory type: 0x20" | |
203 | 1862319-1862340 spiflash: field: "Device ID: 0x15" | |
204 | 1862253-1862340 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
205 | 1915893-1915912 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
206 | 1915918-1915937 spiflash: field: "Manufacturer ID: 0xc2" | |
207 | 1915939-1915958 spiflash: field: "Memory type: 0x20" | |
208 | 1915959-1915980 spiflash: field: "Device ID: 0x15" | |
209 | 1915893-1915980 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
210 | 1965781-1965802 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
211 | 1965806-1965827 spiflash: field: "Manufacturer ID: 0xc2" | |
212 | 1965827-1965848 spiflash: field: "Memory type: 0x20" | |
213 | 1965848-1965867 spiflash: field: "Device ID: 0x15" | |
214 | 1965781-1965867 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
215 | 2016378-2016399 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
216 | 2016403-2016424 spiflash: field: "Manufacturer ID: 0xc2" | |
217 | 2016424-2016445 spiflash: field: "Memory type: 0x20" | |
218 | 2016445-2016466 spiflash: field: "Device ID: 0x15" | |
219 | 2016378-2016466 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
220 | 2062737-2062756 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
221 | 2062762-2062781 spiflash: field: "Manufacturer ID: 0xc2" | |
222 | 2062783-2062802 spiflash: field: "Memory type: 0x20" | |
223 | 2062804-2062823 spiflash: field: "Device ID: 0x15" | |
224 | 2062737-2062823 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
225 | 2116363-2116384 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
226 | 2116388-2116409 spiflash: field: "Manufacturer ID: 0xc2" | |
227 | 2116409-2116430 spiflash: field: "Memory type: 0x20" | |
228 | 2116430-2116449 spiflash: field: "Device ID: 0x15" | |
229 | 2116363-2116449 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
230 | 2162719-2162740 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
231 | 2162744-2162765 spiflash: field: "Manufacturer ID: 0xc2" | |
232 | 2162765-2162786 spiflash: field: "Memory type: 0x20" | |
233 | 2162786-2162805 spiflash: field: "Device ID: 0x15" | |
234 | 2162719-2162805 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
235 | 2216867-2216888 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
236 | 2216892-2216913 spiflash: field: "Manufacturer ID: 0xc2" | |
237 | 2216913-2216934 spiflash: field: "Memory type: 0x20" | |
238 | 2216934-2216953 spiflash: field: "Device ID: 0x15" | |
239 | 2216867-2216953 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
240 | 2262722-2262743 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
241 | 2262747-2262768 spiflash: field: "Manufacturer ID: 0xc2" | |
242 | 2262768-2262789 spiflash: field: "Memory type: 0x20" | |
243 | 2262789-2262810 spiflash: field: "Device ID: 0x15" | |
244 | 2262722-2262810 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
245 | 2316335-2316356 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
246 | 2316360-2316381 spiflash: field: "Manufacturer ID: 0xc2" | |
247 | 2316381-2316402 spiflash: field: "Memory type: 0x20" | |
248 | 2316402-2316421 spiflash: field: "Device ID: 0x15" | |
249 | 2316335-2316421 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
250 | 2362687-2362708 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
251 | 2362712-2362733 spiflash: field: "Manufacturer ID: 0xc2" | |
252 | 2362733-2362754 spiflash: field: "Memory type: 0x20" | |
253 | 2362754-2362773 spiflash: field: "Device ID: 0x15" | |
254 | 2362687-2362773 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
255 | 2416319-2416338 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
256 | 2416344-2416363 spiflash: field: "Manufacturer ID: 0xc2" | |
257 | 2416365-2416384 spiflash: field: "Memory type: 0x20" | |
258 | 2416386-2416405 spiflash: field: "Device ID: 0x15" | |
259 | 2416319-2416405 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
260 | 2462685-2462704 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
261 | 2462710-2462729 spiflash: field: "Manufacturer ID: 0xc2" | |
262 | 2462731-2462750 spiflash: field: "Memory type: 0x20" | |
263 | 2462752-2462771 spiflash: field: "Device ID: 0x15" | |
264 | 2462685-2462771 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
265 | 2516307-2516328 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
266 | 2516332-2516353 spiflash: field: "Manufacturer ID: 0xc2" | |
267 | 2516353-2516372 spiflash: field: "Memory type: 0x20" | |
268 | 2516374-2516393 spiflash: field: "Device ID: 0x15" | |
269 | 2516307-2516393 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
270 | 2562661-2562682 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
271 | 2562686-2562707 spiflash: field: "Manufacturer ID: 0xc2" | |
272 | 2562707-2562728 spiflash: field: "Memory type: 0x20" | |
273 | 2562728-2562749 spiflash: field: "Device ID: 0x15" | |
274 | 2562661-2562749 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
275 | 2616295-2616316 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
276 | 2616320-2616341 spiflash: field: "Manufacturer ID: 0xc2" | |
277 | 2616341-2616362 spiflash: field: "Memory type: 0x20" | |
278 | 2616362-2616381 spiflash: field: "Device ID: 0x15" | |
279 | 2616295-2616381 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
280 | 2662657-2662678 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
281 | 2662682-2662703 spiflash: field: "Manufacturer ID: 0xc2" | |
282 | 2662703-2662722 spiflash: field: "Memory type: 0x20" | |
283 | 2662724-2662743 spiflash: field: "Device ID: 0x15" | |
284 | 2662657-2662743 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
285 | 2716279-2716298 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
286 | 2716304-2716323 spiflash: field: "Manufacturer ID: 0xc2" | |
287 | 2716325-2716344 spiflash: field: "Memory type: 0x20" | |
288 | 2716345-2716366 spiflash: field: "Device ID: 0x15" | |
289 | 2716279-2716366 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
290 | 2762647-2762668 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
291 | 2762672-2762693 spiflash: field: "Manufacturer ID: 0xc2" | |
292 | 2762693-2762714 spiflash: field: "Memory type: 0x20" | |
293 | 2762714-2762733 spiflash: field: "Device ID: 0x15" | |
294 | 2762647-2762733 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
295 | 2815899-2815918 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
296 | 2815924-2815943 spiflash: field: "Manufacturer ID: 0xc2" | |
297 | 2815945-2815964 spiflash: field: "Memory type: 0x20" | |
298 | 2815966-2815985 spiflash: field: "Device ID: 0x15" | |
299 | 2815899-2815985 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
300 | 2866260-2866279 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
301 | 2866285-2866304 spiflash: field: "Manufacturer ID: 0xc2" | |
302 | 2866306-2866325 spiflash: field: "Memory type: 0x20" | |
303 | 2866327-2866346 spiflash: field: "Device ID: 0x15" | |
304 | 2866260-2866346 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
305 | 2912623-2912642 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
306 | 2912648-2912667 spiflash: field: "Manufacturer ID: 0xc2" | |
307 | 2912669-2912688 spiflash: field: "Memory type: 0x20" | |
308 | 2912690-2912709 spiflash: field: "Device ID: 0x15" | |
309 | 2912623-2912709 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
310 | 2966247-2966268 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
311 | 2966272-2966293 spiflash: field: "Manufacturer ID: 0xc2" | |
312 | 2966293-2966314 spiflash: field: "Memory type: 0x20" | |
313 | 2966314-2966333 spiflash: field: "Device ID: 0x15" | |
314 | 2966247-2966333 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
315 | 3012611-3012632 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
316 | 3012636-3012657 spiflash: field: "Manufacturer ID: 0xc2" | |
317 | 3012657-3012676 spiflash: field: "Memory type: 0x20" | |
318 | 3012678-3012697 spiflash: field: "Device ID: 0x15" | |
319 | 3012611-3012697 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
320 | 3066235-3066256 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
321 | 3066260-3066281 spiflash: field: "Manufacturer ID: 0xc2" | |
322 | 3066281-3066302 spiflash: field: "Memory type: 0x20" | |
323 | 3066302-3066323 spiflash: field: "Device ID: 0x15" | |
324 | 3066235-3066323 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
325 | 3112228-3112249 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
326 | 3112253-3112274 spiflash: field: "Manufacturer ID: 0xc2" | |
327 | 3112274-3112293 spiflash: field: "Memory type: 0x20" | |
328 | 3112295-3112314 spiflash: field: "Device ID: 0x15" | |
329 | 3112228-3112314 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
330 | 3165854-3165873 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
331 | 3165879-3165898 spiflash: field: "Manufacturer ID: 0xc2" | |
332 | 3165900-3165919 spiflash: field: "Memory type: 0x20" | |
333 | 3165921-3165940 spiflash: field: "Device ID: 0x15" | |
334 | 3165854-3165940 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
335 | 3215707-3215726 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
336 | 3215732-3215751 spiflash: field: "Manufacturer ID: 0xc2" | |
337 | 3215752-3215773 spiflash: field: "Memory type: 0x20" | |
338 | 3215773-3215794 spiflash: field: "Device ID: 0x15" | |
339 | 3215707-3215794 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
340 | 3265834-3265853 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
341 | 3265859-3265878 spiflash: field: "Manufacturer ID: 0xc2" | |
342 | 3265880-3265899 spiflash: field: "Memory type: 0x20" | |
343 | 3265900-3265921 spiflash: field: "Device ID: 0x15" | |
344 | 3265834-3265921 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
345 | 3315694-3315715 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
346 | 3315719-3315740 spiflash: field: "Manufacturer ID: 0xc2" | |
347 | 3315740-3315761 spiflash: field: "Memory type: 0x20" | |
348 | 3315761-3315780 spiflash: field: "Device ID: 0x15" | |
349 | 3315694-3315780 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
350 | 3365689-3365708 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
351 | 3365714-3365733 spiflash: field: "Manufacturer ID: 0xc2" | |
352 | 3365735-3365754 spiflash: field: "Memory type: 0x20" | |
353 | 3365756-3365775 spiflash: field: "Device ID: 0x15" | |
354 | 3365689-3365775 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
355 | 3441210-3441229 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
356 | 3441235-3441254 spiflash: field: "Manufacturer ID: 0xc2" | |
357 | 3441256-3441275 spiflash: field: "Memory type: 0x20" | |
358 | 3441276-3441297 spiflash: field: "Device ID: 0x15" | |
359 | 3441210-3441297 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
360 | 3485063-3485082 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
361 | 3485088-3485107 spiflash: field: "Manufacturer ID: 0xc2" | |
362 | 3485109-3485128 spiflash: field: "Memory type: 0x20" | |
363 | 3485130-3485149 spiflash: field: "Device ID: 0x15" | |
364 | 3485063-3485149 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
365 | 3516119-3516138 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
366 | 3516144-3516163 spiflash: field: "Manufacturer ID: 0xc2" | |
367 | 3516165-3516184 spiflash: field: "Memory type: 0x20" | |
368 | 3516186-3516205 spiflash: field: "Device ID: 0x15" | |
369 | 3516119-3516205 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
370 | 3562546-3562565 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
371 | 3562571-3562590 spiflash: field: "Manufacturer ID: 0xc2" | |
372 | 3562592-3562611 spiflash: field: "Memory type: 0x20" | |
373 | 3562612-3562633 spiflash: field: "Device ID: 0x15" | |
374 | 3562546-3562633 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
375 | 3612018-3612037 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
376 | 3612043-3612062 spiflash: field: "Manufacturer ID: 0xc2" | |
377 | 3612063-3612084 spiflash: field: "Memory type: 0x20" | |
378 | 3612084-3612105 spiflash: field: "Device ID: 0x15" | |
379 | 3612018-3612105 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
380 | 3665802-3665821 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
381 | 3665827-3665846 spiflash: field: "Manufacturer ID: 0xc2" | |
382 | 3665848-3665867 spiflash: field: "Memory type: 0x20" | |
383 | 3665868-3665889 spiflash: field: "Device ID: 0x15" | |
384 | 3665802-3665889 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
385 | 3716158-3716177 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
386 | 3716183-3716202 spiflash: field: "Manufacturer ID: 0xc2" | |
387 | 3716203-3716224 spiflash: field: "Memory type: 0x20" | |
388 | 3716224-3716245 spiflash: field: "Device ID: 0x15" | |
389 | 3716158-3716245 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
390 | 3763016-3763035 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
391 | 3763041-3763060 spiflash: field: "Manufacturer ID: 0xc2" | |
392 | 3763062-3763081 spiflash: field: "Memory type: 0x20" | |
393 | 3763082-3763103 spiflash: field: "Device ID: 0x15" | |
394 | 3763016-3763103 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
395 | 3816134-3816155 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
396 | 3816159-3816180 spiflash: field: "Manufacturer ID: 0xc2" | |
397 | 3816180-3816199 spiflash: field: "Memory type: 0x20" | |
398 | 3816201-3816220 spiflash: field: "Device ID: 0x15" | |
399 | 3816134-3816220 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
400 | 3862495-3862514 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
401 | 3862520-3862539 spiflash: field: "Manufacturer ID: 0xc2" | |
402 | 3862541-3862560 spiflash: field: "Memory type: 0x20" | |
403 | 3862561-3862582 spiflash: field: "Device ID: 0x15" | |
404 | 3862495-3862582 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
405 | 3916120-3916139 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
406 | 3916145-3916164 spiflash: field: "Manufacturer ID: 0xc2" | |
407 | 3916166-3916185 spiflash: field: "Memory type: 0x20" | |
408 | 3916186-3916207 spiflash: field: "Device ID: 0x15" | |
409 | 3916120-3916207 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
410 | 3962103-3962124 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
411 | 3962128-3962149 spiflash: field: "Manufacturer ID: 0xc2" | |
412 | 3962149-3962170 spiflash: field: "Memory type: 0x20" | |
413 | 3962170-3962189 spiflash: field: "Device ID: 0x15" | |
414 | 3962103-3962189 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
415 | 4015644-4015663 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
416 | 4015669-4015688 spiflash: field: "Manufacturer ID: 0xc2" | |
417 | 4015690-4015709 spiflash: field: "Memory type: 0x20" | |
418 | 4015710-4015731 spiflash: field: "Device ID: 0x15" | |
419 | 4015644-4015731 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
420 | 4066100-4066119 spiflash: field: "Command: Read status register (RDSR)" "Command: Read status register" "Cmd: Read status register" "Cmd: RDSR" "RDSR" | |
421 | 4066125-4066144 spiflash: bit: "No write operation in progress. | |
422 | Internal write enable latch is not set. | |
423 | Block protection bits (BP3-BP0): 0x0. | |
424 | Device is not in continuously program mode (CP mode). | |
425 | Status register writes are allowed. | |
426 | " | |
427 | 4066125-4066144 spiflash: field: "Status register" | |
428 | 4066100-4066144 spiflash: rdsr: "Command: Read status register (RDSR)" "Command: Read status register" "Cmd: Read status register" "Cmd: RDSR" "RDSR" | |
429 | 4066145-4066165 spiflash: bit: "No write operation in progress. | |
430 | Internal write enable latch is not set. | |
431 | Block protection bits (BP3-BP0): 0x0. | |
432 | Device is not in continuously program mode (CP mode). | |
433 | Status register writes are allowed. | |
434 | " | |
435 | 4066145-4066165 spiflash: field: "Status register" | |
436 | 4066100-4066165 spiflash: rdsr: "Command: Read status register (RDSR)" "Command: Read status register" "Cmd: Read status register" "Cmd: RDSR" "RDSR" | |
437 | 4114020-4114039 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
438 | 4114045-4114064 spiflash: field: "Manufacturer ID: 0xc2" | |
439 | 4114066-4114085 spiflash: field: "Memory type: 0x20" | |
440 | 4114086-4114107 spiflash: field: "Device ID: 0x15" | |
441 | 4114020-4114107 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
442 | 4165584-4165603 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
443 | 4165609-4165628 spiflash: field: "Manufacturer ID: 0xc2" | |
444 | 4165629-4165649 spiflash: field: "Memory type: 0x20" | |
445 | 4165650-4165671 spiflash: field: "Device ID: 0x15" | |
446 | 4165584-4165671 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
447 | 4211932-4211953 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
448 | 4211957-4211978 spiflash: field: "Manufacturer ID: 0xc2" | |
449 | 4211978-4211999 spiflash: field: "Memory type: 0x20" | |
450 | 4211999-4212018 spiflash: field: "Device ID: 0x15" | |
451 | 4211932-4212018 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
452 | 4265063-4265084 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
453 | 4265088-4265109 spiflash: field: "Manufacturer ID: 0xc2" | |
454 | 4265109-4265128 spiflash: field: "Memory type: 0x20" | |
455 | 4265130-4265149 spiflash: field: "Device ID: 0x15" | |
456 | 4265063-4265149 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
457 | 4316206-4316225 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
458 | 4316231-4316250 spiflash: field: "Manufacturer ID: 0xc2" | |
459 | 4316251-4316272 spiflash: field: "Memory type: 0x20" | |
460 | 4316272-4316293 spiflash: field: "Device ID: 0x15" | |
461 | 4316206-4316293 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
462 | 4362060-4362079 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
463 | 4362085-4362104 spiflash: field: "Manufacturer ID: 0xc2" | |
464 | 4362105-4362126 spiflash: field: "Memory type: 0x20" | |
465 | 4362126-4362147 spiflash: field: "Device ID: 0x15" | |
466 | 4362060-4362147 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
467 | 4416595-4416616 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
468 | 4416620-4416641 spiflash: field: "Manufacturer ID: 0xc2" | |
469 | 4416641-4416662 spiflash: field: "Memory type: 0x20" | |
470 | 4416662-4416683 spiflash: field: "Device ID: 0x15" | |
471 | 4416595-4416683 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
472 | 4465681-4465700 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
473 | 4465706-4465725 spiflash: field: "Manufacturer ID: 0xc2" | |
474 | 4465726-4465747 spiflash: field: "Memory type: 0x20" | |
475 | 4465747-4465768 spiflash: field: "Device ID: 0x15" | |
476 | 4465681-4465768 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
477 | 4515670-4515689 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
478 | 4515695-4515714 spiflash: field: "Manufacturer ID: 0xc2" | |
479 | 4515716-4515735 spiflash: field: "Memory type: 0x20" | |
480 | 4515737-4515756 spiflash: field: "Device ID: 0x15" | |
481 | 4515670-4515756 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
482 | 4566032-4566053 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
483 | 4566057-4566078 spiflash: field: "Manufacturer ID: 0xc2" | |
484 | 4566078-4566099 spiflash: field: "Memory type: 0x20" | |
485 | 4566099-4566120 spiflash: field: "Device ID: 0x15" | |
486 | 4566032-4566120 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
487 | 4612013-4612034 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
488 | 4612038-4612059 spiflash: field: "Manufacturer ID: 0xc2" | |
489 | 4612059-4612078 spiflash: field: "Memory type: 0x20" | |
490 | 4612080-4612099 spiflash: field: "Device ID: 0x15" | |
491 | 4612013-4612099 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
492 | 4665639-4665660 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
493 | 4665664-4665685 spiflash: field: "Manufacturer ID: 0xc2" | |
494 | 4665685-4665706 spiflash: field: "Memory type: 0x20" | |
495 | 4665706-4665727 spiflash: field: "Device ID: 0x15" | |
496 | 4665639-4665727 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
497 | 4715923-4715942 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
498 | 4715948-4715967 spiflash: field: "Manufacturer ID: 0xc2" | |
499 | 4715969-4715988 spiflash: field: "Memory type: 0x20" | |
500 | 4715989-4716010 spiflash: field: "Device ID: 0x15" | |
501 | 4715923-4716010 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
502 | 4761989-4762008 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
503 | 4762014-4762033 spiflash: field: "Manufacturer ID: 0xc2" | |
504 | 4762035-4762054 spiflash: field: "Memory type: 0x20" | |
505 | 4762055-4762076 spiflash: field: "Device ID: 0x15" | |
506 | 4761989-4762076 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
507 | 4816081-4816100 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
508 | 4816106-4816125 spiflash: field: "Manufacturer ID: 0xc2" | |
509 | 4816127-4816146 spiflash: field: "Memory type: 0x20" | |
510 | 4816148-4816167 spiflash: field: "Device ID: 0x15" | |
511 | 4816081-4816167 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
512 | 4861985-4862004 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
513 | 4862010-4862029 spiflash: field: "Manufacturer ID: 0xc2" | |
514 | 4862031-4862050 spiflash: field: "Memory type: 0x20" | |
515 | 4862052-4862071 spiflash: field: "Device ID: 0x15" | |
516 | 4861985-4862071 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
517 | 4915613-4915632 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
518 | 4915638-4915657 spiflash: field: "Manufacturer ID: 0xc2" | |
519 | 4915659-4915678 spiflash: field: "Memory type: 0x20" | |
520 | 4915680-4915699 spiflash: field: "Device ID: 0x15" | |
521 | 4915613-4915699 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
522 | 4966500-4966521 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
523 | 4966525-4966546 spiflash: field: "Manufacturer ID: 0xc2" | |
524 | 4966546-4966565 spiflash: field: "Memory type: 0x20" | |
525 | 4966567-4966586 spiflash: field: "Device ID: 0x15" | |
526 | 4966500-4966586 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
527 | 5012346-5012367 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
528 | 5012371-5012392 spiflash: field: "Manufacturer ID: 0xc2" | |
529 | 5012392-5012413 spiflash: field: "Memory type: 0x20" | |
530 | 5012413-5012434 spiflash: field: "Device ID: 0x15" | |
531 | 5012346-5012434 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
532 | 5065449-5065470 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
533 | 5065474-5065495 spiflash: field: "Manufacturer ID: 0xc2" | |
534 | 5065495-5065514 spiflash: field: "Memory type: 0x20" | |
535 | 5065516-5065535 spiflash: field: "Device ID: 0x15" | |
536 | 5065449-5065535 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
537 | 5115964-5115985 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
538 | 5115989-5116010 spiflash: field: "Manufacturer ID: 0xc2" | |
539 | 5116010-5116029 spiflash: field: "Memory type: 0x20" | |
540 | 5116031-5116050 spiflash: field: "Device ID: 0x15" | |
541 | 5115964-5116050 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
542 | 5162317-5162338 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
543 | 5162342-5162363 spiflash: field: "Manufacturer ID: 0xc2" | |
544 | 5162363-5162384 spiflash: field: "Memory type: 0x20" | |
545 | 5162384-5162403 spiflash: field: "Device ID: 0x15" | |
546 | 5162317-5162403 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
547 | 5215440-5215461 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
548 | 5215465-5215486 spiflash: field: "Manufacturer ID: 0xc2" | |
549 | 5215486-5215507 spiflash: field: "Memory type: 0x20" | |
550 | 5215507-5215526 spiflash: field: "Device ID: 0x15" | |
551 | 5215440-5215526 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
552 | 5265941-5265960 spiflash: field: "Command: Read electronic manufacturer & device ID (REMS)" "Command: Read electronic manufacturer & device ID" "Cmd: Read electronic manufacturer & device ID" "Cmd: REMS" "REMS" | |
553 | 5265962-5265981 spiflash: field: "Dummy byte: 0x00" | |
554 | 5265982-5266003 spiflash: field: "Dummy byte: 0x00" | |
555 | 5266003-5266024 spiflash: field: "Master wants manufacturer ID first" | |
556 | 5266028-5266049 spiflash: field: "Manufacturer ID: 0xc2" | |
557 | 5266049-5266070 spiflash: field: "Device ID: 0x14" | |
558 | 5265941-5266070 spiflash: rems: "Read electronic manufacturer & device ID (REMS): Device = Macronix MX25L1605D" "Read electronic manufacturer & device ID: Device = Macronix MX25L1605D" "REMS: Device = Macronix MX25L1605D" "Device = Macronix MX25L1605D" "Macronix MX25L1605D" | |
559 | 5312297-5312318 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
560 | 5312322-5312343 spiflash: field: "Manufacturer ID: 0xc2" | |
561 | 5312343-5312362 spiflash: field: "Memory type: 0x20" | |
562 | 5312364-5312383 spiflash: field: "Device ID: 0x15" | |
563 | 5312297-5312383 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
564 | 5368034-5368055 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
565 | 5368059-5368080 spiflash: field: "Manufacturer ID: 0xc2" | |
566 | 5368080-5368101 spiflash: field: "Memory type: 0x20" | |
567 | 5368101-5368120 spiflash: field: "Device ID: 0x15" | |
568 | 5368034-5368120 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
569 | 5415919-5415940 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
570 | 5415944-5415965 spiflash: field: "Manufacturer ID: 0xc2" | |
571 | 5415965-5415986 spiflash: field: "Memory type: 0x20" | |
572 | 5415986-5416007 spiflash: field: "Device ID: 0x15" | |
573 | 5415919-5416007 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
574 | 5461749-5461768 spiflash: field: "Command: Read electronic manufacturer & device ID (REMS)" "Command: Read electronic manufacturer & device ID" "Cmd: Read electronic manufacturer & device ID" "Cmd: REMS" "REMS" | |
575 | 5461770-5461789 spiflash: field: "Dummy byte: 0x00" | |
576 | 5461790-5461811 spiflash: field: "Dummy byte: 0x00" | |
577 | 5461811-5461832 spiflash: field: "Master wants manufacturer ID first" | |
578 | 5461836-5461857 spiflash: field: "Manufacturer ID: 0xc2" | |
579 | 5461857-5461878 spiflash: field: "Device ID: 0x14" | |
580 | 5461749-5461878 spiflash: rems: "Read electronic manufacturer & device ID (REMS): Device = Macronix MX25L1605D" "Read electronic manufacturer & device ID: Device = Macronix MX25L1605D" "REMS: Device = Macronix MX25L1605D" "Device = Macronix MX25L1605D" "Macronix MX25L1605D" | |
581 | 5515397-5515417 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
582 | 5515423-5515443 spiflash: field: "Manufacturer ID: 0xc2" | |
583 | 5515443-5515464 spiflash: field: "Memory type: 0x20" | |
584 | 5515464-5515485 spiflash: field: "Device ID: 0x15" | |
585 | 5515397-5515485 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
586 | 5565899-5565918 spiflash: field: "Command: Release from deep powerdown / Read electronic ID (RDP/RES)" "Command: Release from deep powerdown / Read electronic ID" "Cmd: Release from deep powerdown / Read electronic ID" "Cmd: RDP/RES" "RDP/RES" | |
587 | 5565920-5565939 spiflash: field: "Dummy byte: 00" | |
588 | 5565941-5565960 spiflash: field: "Dummy byte: 00" | |
589 | 5565961-5565982 spiflash: field: "Dummy byte: 00" | |
590 | 5565986-5566007 spiflash: field: "Device ID: MX25L1605D" | |
591 | 5565899-5566007 spiflash: rdp/res: "Release from deep powerdown / Read electronic ID (RDP/RES): Device = Macronix MX25L1605D" "Release from deep powerdown / Read electronic ID: Device = Macronix MX25L1605D" "RDP/RES: Device = Macronix MX25L1605D" "Device = Macronix MX25L1605D" "Macronix MX25L1605D" | |
592 | 5566007-5566028 spiflash: bit: "Unknown command: 0x00" | |
593 | 5611869-5611890 spiflash: field: "Command: Read electronic manufacturer & device ID (REMS)" "Command: Read electronic manufacturer & device ID" "Cmd: Read electronic manufacturer & device ID" "Cmd: REMS" "REMS" | |
594 | 5611890-5611909 spiflash: field: "Dummy byte: 0x00" | |
595 | 5611911-5611930 spiflash: field: "Dummy byte: 0x00" | |
596 | 5611932-5611951 spiflash: field: "Master wants manufacturer ID first" | |
597 | 5611957-5611976 spiflash: field: "Manufacturer ID: 0xc2" | |
598 | 5611977-5611998 spiflash: field: "Device ID: 0x14" | |
599 | 5611869-5611998 spiflash: rems: "Read electronic manufacturer & device ID (REMS): Device = Macronix MX25L1605D" "Read electronic manufacturer & device ID: Device = Macronix MX25L1605D" "REMS: Device = Macronix MX25L1605D" "Device = Macronix MX25L1605D" "Macronix MX25L1605D" | |
600 | 5662760-5662779 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
601 | 5662785-5662804 spiflash: field: "Manufacturer ID: 0xc2" | |
602 | 5662805-5662826 spiflash: field: "Memory type: 0x20" | |
603 | 5662826-5662847 spiflash: field: "Device ID: 0x15" | |
604 | 5662760-5662847 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
605 | 5716930-5716949 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
606 | 5716955-5716974 spiflash: field: "Manufacturer ID: 0xc2" | |
607 | 5716975-5716996 spiflash: field: "Memory type: 0x20" | |
608 | 5716996-5717017 spiflash: field: "Device ID: 0x15" | |
609 | 5716930-5717017 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
610 | 5761849-5761870 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
611 | 5761874-5761895 spiflash: field: "Manufacturer ID: 0xc2" | |
612 | 5761895-5761916 spiflash: field: "Memory type: 0x20" | |
613 | 5761916-5761937 spiflash: field: "Device ID: 0x15" | |
614 | 5761849-5761937 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
615 | 5815495-5815516 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
616 | 5815520-5815541 spiflash: field: "Manufacturer ID: 0xc2" | |
617 | 5815541-5815562 spiflash: field: "Memory type: 0x20" | |
618 | 5815562-5815581 spiflash: field: "Device ID: 0x15" | |
619 | 5815495-5815581 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
620 | 5865857-5865878 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
621 | 5865882-5865903 spiflash: field: "Manufacturer ID: 0xc2" | |
622 | 5865903-5865924 spiflash: field: "Memory type: 0x20" | |
623 | 5865924-5865945 spiflash: field: "Device ID: 0x15" | |
624 | 5865857-5865945 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
625 | 5911702-5911721 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
626 | 5911727-5911746 spiflash: field: "Manufacturer ID: 0xc2" | |
627 | 5911748-5911767 spiflash: field: "Memory type: 0x20" | |
628 | 5911768-5911789 spiflash: field: "Device ID: 0x15" | |
629 | 5911702-5911789 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
630 | 5991371-5991392 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
631 | 5991396-5991417 spiflash: field: "Manufacturer ID: 0xc2" | |
632 | 5991417-5991438 spiflash: field: "Memory type: 0x20" | |
633 | 5991438-5991457 spiflash: field: "Device ID: 0x15" | |
634 | 5991371-5991457 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
635 | 6015840-6015859 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
636 | 6015865-6015884 spiflash: field: "Manufacturer ID: 0xc2" | |
637 | 6015886-6015905 spiflash: field: "Memory type: 0x20" | |
638 | 6015907-6015926 spiflash: field: "Device ID: 0x15" | |
639 | 6015840-6015926 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
640 | 6061693-6061712 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
641 | 6061718-6061737 spiflash: field: "Manufacturer ID: 0xc2" | |
642 | 6061739-6061758 spiflash: field: "Memory type: 0x20" | |
643 | 6061760-6061779 spiflash: field: "Device ID: 0x15" | |
644 | 6061693-6061779 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
645 | 6115320-6115339 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
646 | 6115345-6115364 spiflash: field: "Manufacturer ID: 0xc2" | |
647 | 6115366-6115385 spiflash: field: "Memory type: 0x20" | |
648 | 6115386-6115407 spiflash: field: "Device ID: 0x15" | |
649 | 6115320-6115407 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
650 | 6165822-6165841 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
651 | 6165847-6165866 spiflash: field: "Manufacturer ID: 0xc2" | |
652 | 6165868-6165887 spiflash: field: "Memory type: 0x20" | |
653 | 6165889-6165908 spiflash: field: "Device ID: 0x15" | |
654 | 6165822-6165908 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
655 | 6215812-6215833 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
656 | 6215837-6215858 spiflash: field: "Manufacturer ID: 0xc2" | |
657 | 6215858-6215879 spiflash: field: "Memory type: 0x20" | |
658 | 6215879-6215900 spiflash: field: "Device ID: 0x15" | |
659 | 6215812-6215900 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
660 | 6265266-6265287 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
661 | 6265291-6265312 spiflash: field: "Manufacturer ID: 0xc2" | |
662 | 6265312-6265333 spiflash: field: "Memory type: 0x20" | |
663 | 6265333-6265352 spiflash: field: "Device ID: 0x15" | |
664 | 6265266-6265352 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
665 | 6315297-6315316 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
666 | 6315322-6315341 spiflash: field: "Manufacturer ID: 0xc2" | |
667 | 6315343-6315362 spiflash: field: "Memory type: 0x20" | |
668 | 6315363-6315384 spiflash: field: "Device ID: 0x15" | |
669 | 6315297-6315384 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
670 | 6365702-6365721 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
671 | 6365727-6365746 spiflash: field: "Manufacturer ID: 0xc2" | |
672 | 6365747-6365768 spiflash: field: "Memory type: 0x20" | |
673 | 6365768-6365789 spiflash: field: "Device ID: 0x15" | |
674 | 6365702-6365789 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
675 | 6415782-6415803 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
676 | 6415807-6415828 spiflash: field: "Manufacturer ID: 0xc2" | |
677 | 6415828-6415849 spiflash: field: "Memory type: 0x20" | |
678 | 6415849-6415870 spiflash: field: "Device ID: 0x15" | |
679 | 6415782-6415870 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
680 | 6466245-6466266 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
681 | 6466270-6466291 spiflash: field: "Manufacturer ID: 0xc2" | |
682 | 6466291-6466312 spiflash: field: "Memory type: 0x20" | |
683 | 6466312-6466333 spiflash: field: "Device ID: 0x15" | |
684 | 6466245-6466333 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
685 | 6515714-6515735 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
686 | 6515739-6515760 spiflash: field: "Manufacturer ID: 0xc2" | |
687 | 6515760-6515781 spiflash: field: "Memory type: 0x20" | |
688 | 6515781-6515800 spiflash: field: "Device ID: 0x15" | |
689 | 6515714-6515800 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
690 | 6565709-6565730 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
691 | 6565734-6565755 spiflash: field: "Manufacturer ID: 0xc2" | |
692 | 6565755-6565774 spiflash: field: "Memory type: 0x20" | |
693 | 6565776-6565795 spiflash: field: "Device ID: 0x15" | |
694 | 6565709-6565795 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
695 | 6615254-6615273 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
696 | 6615279-6615298 spiflash: field: "Manufacturer ID: 0xc2" | |
697 | 6615300-6615319 spiflash: field: "Memory type: 0x20" | |
698 | 6615320-6615341 spiflash: field: "Device ID: 0x15" | |
699 | 6615254-6615341 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
700 | 6665255-6665276 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
701 | 6665280-6665301 spiflash: field: "Manufacturer ID: 0xc2" | |
702 | 6665301-6665320 spiflash: field: "Memory type: 0x20" | |
703 | 6665322-6665341 spiflash: field: "Device ID: 0x15" | |
704 | 6665255-6665341 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
705 | 6715747-6715766 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
706 | 6715772-6715791 spiflash: field: "Manufacturer ID: 0xc2" | |
707 | 6715793-6715812 spiflash: field: "Memory type: 0x20" | |
708 | 6715814-6715833 spiflash: field: "Device ID: 0x15" | |
709 | 6715747-6715833 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
710 | 6762135-6762156 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
711 | 6762160-6762181 spiflash: field: "Manufacturer ID: 0xc2" | |
712 | 6762181-6762202 spiflash: field: "Memory type: 0x20" | |
713 | 6762202-6762223 spiflash: field: "Device ID: 0x15" | |
714 | 6762135-6762223 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
715 | 6812219-6812240 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
716 | 6812244-6812265 spiflash: field: "Manufacturer ID: 0xc2" | |
717 | 6812265-6812286 spiflash: field: "Memory type: 0x20" | |
718 | 6812286-6812305 spiflash: field: "Device ID: 0x15" | |
719 | 6812219-6812305 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
720 | 6865237-6865256 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
721 | 6865262-6865281 spiflash: field: "Manufacturer ID: 0xc2" | |
722 | 6865283-6865302 spiflash: field: "Memory type: 0x20" | |
723 | 6865303-6865324 spiflash: field: "Device ID: 0x15" | |
724 | 6865237-6865324 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
725 | 6915716-6915737 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
726 | 6915741-6915762 spiflash: field: "Manufacturer ID: 0xc2" | |
727 | 6915762-6915781 spiflash: field: "Memory type: 0x20" | |
728 | 6915783-6915802 spiflash: field: "Device ID: 0x15" | |
729 | 6915716-6915802 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
730 | 6965251-6965272 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
731 | 6965276-6965297 spiflash: field: "Manufacturer ID: 0xc2" | |
732 | 6965297-6965318 spiflash: field: "Memory type: 0x20" | |
733 | 6965318-6965337 spiflash: field: "Device ID: 0x15" | |
734 | 6965251-6965337 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
735 | 7015206-7015227 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
736 | 7015231-7015252 spiflash: field: "Manufacturer ID: 0xc2" | |
737 | 7015252-7015273 spiflash: field: "Memory type: 0x20" | |
738 | 7015273-7015292 spiflash: field: "Device ID: 0x15" | |
739 | 7015206-7015292 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
740 | 7066223-7066242 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
741 | 7066248-7066267 spiflash: field: "Manufacturer ID: 0xc2" | |
742 | 7066268-7066289 spiflash: field: "Memory type: 0x20" | |
743 | 7066289-7066310 spiflash: field: "Device ID: 0x15" | |
744 | 7066223-7066310 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
745 | 7066310-7066331 spiflash: bit: "Unknown command: 0xff" | |
746 | 7115602-7115623 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
747 | 7115627-7115648 spiflash: field: "Manufacturer ID: 0xc2" | |
748 | 7115648-7115669 spiflash: field: "Memory type: 0x20" | |
749 | 7115669-7115688 spiflash: field: "Device ID: 0x15" | |
750 | 7115602-7115688 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
751 | 7165683-7165702 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
752 | 7165708-7165727 spiflash: field: "Manufacturer ID: 0xc2" | |
753 | 7165729-7165748 spiflash: field: "Memory type: 0x20" | |
754 | 7165750-7165769 spiflash: field: "Device ID: 0x15" | |
755 | 7165683-7165769 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
756 | 7215676-7215695 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
757 | 7215701-7215720 spiflash: field: "Manufacturer ID: 0xc2" | |
758 | 7215722-7215741 spiflash: field: "Memory type: 0x20" | |
759 | 7215743-7215762 spiflash: field: "Device ID: 0x15" | |
760 | 7215676-7215762 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
761 | 7265672-7265693 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
762 | 7265697-7265718 spiflash: field: "Manufacturer ID: 0xc2" | |
763 | 7265718-7265739 spiflash: field: "Memory type: 0x20" | |
764 | 7265739-7265758 spiflash: field: "Device ID: 0x15" | |
765 | 7265672-7265758 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
766 | 7315661-7315682 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
767 | 7315686-7315707 spiflash: field: "Manufacturer ID: 0xc2" | |
768 | 7315707-7315726 spiflash: field: "Memory type: 0x20" | |
769 | 7315728-7315747 spiflash: field: "Device ID: 0x15" | |
770 | 7315661-7315747 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
771 | 7365682-7365703 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
772 | 7365707-7365728 spiflash: field: "Manufacturer ID: 0xc2" | |
773 | 7365728-7365747 spiflash: field: "Memory type: 0x20" | |
774 | 7365749-7365768 spiflash: field: "Device ID: 0x15" | |
775 | 7365682-7365768 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
776 | 7415597-7415618 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
777 | 7415622-7415643 spiflash: field: "Manufacturer ID: 0xc2" | |
778 | 7415643-7415662 spiflash: field: "Memory type: 0x20" | |
779 | 7415664-7415683 spiflash: field: "Device ID: 0x15" | |
780 | 7415597-7415683 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
781 | 7462463-7462484 spiflash: field: "Command: Read identification (RDID)" "Command: Read identification" "Cmd: Read identification" "Cmd: RDID" "RDID" | |
782 | 7462488-7462509 spiflash: field: "Manufacturer ID: 0xc2" | |
783 | 7462509-7462530 spiflash: field: "Memory type: 0x20" | |
784 | 7462530-7462549 spiflash: field: "Device ID: 0x15" | |
785 | 7462463-7462549 spiflash: rdid: "Read identification (RDID): Device = Macronix MX25L3205D" "Read identification: Device = Macronix MX25L3205D" "RDID: Device = Macronix MX25L3205D" "Device = Macronix MX25L3205D" "Macronix MX25L3205D" | |
786 | 7515281-7515302 spiflash: field: "Command: Read electronic manufacturer & device ID (REMS)" "Command: Read electronic manufacturer & device ID" "Cmd: Read electronic manufacturer & device ID" "Cmd: REMS" "REMS" | |
787 | 7515302-7515321 spiflash: field: "Dummy byte: 0x00" | |
788 | 7515323-7515342 spiflash: field: "Dummy byte: 0x00" | |
789 | 7515344-7515363 spiflash: field: "Master wants manufacturer ID first" | |
790 | 7515369-7515388 spiflash: field: "Manufacturer ID: 0xc2" | |
791 | 7515389-7515410 spiflash: field: "Device ID: 0x14" | |
792 | 7515281-7515410 spiflash: rems: "Read electronic manufacturer & device ID (REMS): Device = Macronix MX25L1605D" "Read electronic manufacturer & device ID: Device = Macronix MX25L1605D" "REMS: Device = Macronix MX25L1605D" "Device = Macronix MX25L1605D" "Macronix MX25L1605D" |