Difference between revisions of "Rohde&Schwarz HMO 3000 series"

From sigrok
Jump to navigation Jump to search
Line 10: Line 10:
| triggers            = slope, pulse width, logic, video, risetime, runt, serial bus (optional)
| triggers            = slope, pulse width, logic, video, risetime, runt, serial bus (optional)
| input_impedance    = 1MΩ‖13pF 200Vp CAT I, 50Ω 5V RMS
| input_impedance    = 1MΩ‖13pF 200Vp CAT I, 50Ω 5V RMS
| memory              = 8/16 Mpts (model dependent)
| memory              = 8 Mpts
| display            = 6.5" VGA (640x480), 256 colors
| display            = 6.5" VGA (640x480), 256 colors
| connectivity        = USB host/device, RS232, ethernet (optional), GPIB (optional)
| connectivity        = USB host/device, RS232, ethernet (optional), GPIB (optional)

Revision as of 00:41, 23 October 2018

Rohde&Schwarz HMO3000
File:HMO3000.jpg
Status supported
Source code hameg-hmo
Channels 2-4 analog, 16 digital
Samplerate 4GSa/s (interleaved), 2GSa/s (non interleaved)
Analog bandwidth 300-500MHz (depending on model)
Vertical resolution 8 bits (HiRes up to 16 bits)
Triggers slope, pulse width, logic, video, risetime, runt, serial bus (optional)
Input impedance 1MΩ‖13pF 200Vp CAT I, 50Ω 5V RMS
Memory 8 Mpts
Display 6.5" VGA (640x480), 256 colors
Connectivity USB host/device, RS232, ethernet (optional), GPIB (optional)
Features math (+, —, x, /), FFT, pattern generator, statistics, frequency counter, digital voltmeter, vertical sensitivity: 1mV/div - 5V/div
Website rohde-schwarz.com

The Rohde&Schwarz HMO3000 series are 300-500MHz, 4GSa/s, 2-4 analog channels and 16 digital channels mixed-signal oscilloscopes. This series was previously branded Hameg.

All models support different extension modules which provide different connectivity options.

Most models come with a HO730 (USB, Ethernet) module, other modules like the HO720 (RS232, USB) and the HO740 (GPIB) are available optionally.

All models come with analog probes (specific probe might depend on the scope capabilities).

Digital probes (8 or 16 channels) are optional and can be purchased separately, see HO3508.

The HMO3000 series has been discontinued in the first-half of 2018.

Devices

Model Bandwidth Analog Channels Digital Channels
HMO3032 300MHz 2 16
HMO3034 300MHz 4 16
HMO3042 400MHz 2 16
HMO3044 400MHz 4 16
HMO3052 500MHz 2 16
HMO3054 500MHz 4 16

Protocol

All the devices use the SCPI protocol (for reference, see the "SCPI Programmers Manual").

The serial parameters are configurable on the device, the standard settings are: 8n1, no handshake, 115200 baud.

All models support USB connection to the computer in both TMC and VPC mode, as well as Ethernet connection (raw TCP over a user-configurable port).

Resources