Atten PPS3203T-3S

From sigrok
Revision as of 02:49, 5 January 2014 by Bert (talk | contribs) (→‎Protocol)
Jump to navigation Jump to search
Atten PPS3203T-3S
Atten PPS3203T-3S.png
Status planned
Channels 3
Voltage/current (CH1) 0-32V / 0-3A
Voltage/current (CH2) 0-32V / 0-3A
Voltage/current (CH3) 0-6V / 0-3A
Connectivity USB, RS232, GPIB (optional)
Website atten.eu

The Atten PPS3203T-3S is a 3-channel programmable power supply (2x 0-32V, 1x 0-6V at 0-3A) with USB and RS232 connectivity.

See Atten PPS3203T-3S/Info for more details (such as lsusb -v output) about the device.

This device is also sold as the Tenma 72-8795 by Farnell/Newark.

Hardware

TODO

Photos

TODO

Protocol

Communication to/from the device is via the RS232 port or serial-USB port. The serial parameters on the device are by default set to 9600 baud, and "data" (data bits) set to 9. This is not a standard number of data bits. The vendor software works around this by using Mark parity. Since this is not a supported parity setting in POSIX, setting parity to None and stop bits to 2 also works.

Every communication to and from the device occurs in 24-byte packets. The device sends a packet only when it receives one from the host. Values such as voltage and current, when set by the host, contain the current values as shown on the display when received from the device. There is thus no way to receive the set values back from the device.

The 24-byte packet is structured as follows:

Byte Description
0 Always 0xaa
1 Always 0x20
2-3 Channel 1 voltage multiplied by 100, big-endian
4-5 Channel 1 current multiplied by 1000, big-endian
6-7 Channel 2 voltage multiplied by 100, big-endian
8-9 Channel 2 current multiplied by 1000, big-endian
10-11 Channel 3 voltage multiplied by 100, big-endian
12-13 Channel 3 current multiplied by 1000, big-endian
14 Always 0x01
15 Output enable: bit 0 = channel 1, bit 1 = channel 2, bit 2 = channel 3
16 Always 0x01
17 Inexplicably used to store the vendor software's language choice. 0 = English, 1 = Chinese
18 Over current protection (OCP): 0 = OCP off, 1 = OCP on
19 Channel output mode: 1=independent (default), 2=series, 3=parallel
20-22 Always 0x00
23 Checksum of all 23 preceding bytes ANDed by 0xff. The checksum is calculated by both the vendor software and device firmware. However, both ignore it entirely when receiving it.