Saleae Logic Pro 8

From sigrok
Revision as of 20:29, 4 September 2018 by Diembed (talk | contribs)
Jump to navigation Jump to search
Saleae Logic Pro 8
Saleae logic pro 8-bottom.png
Status in progress
Source code saleae-logic-pro
Channels 8
Samplerate 500/100MHz (4ch/8ch)
Samplerate (state)
Triggers none (SW-only)
Min/max voltage -25 — 25V tolerant
Threshold voltage 1.2V to 12V digital, -10 to 10V analog
Memory none
Compression yes
Website saleae.com

The Saleae Logic Pro 8 is a USB 3.0-based, 8-channel logic analyzer with 500/100MHz sampling rate (at 4/8 enabled channels) and analog sampling support on all 8 channels.

It is part of the second-generation Saleae Logic series, which consists of the Logic 4, Logic 8, Logic Pro 8 and Logic Pro 16. See Saleae Logic and Saleae Logic8 for the predecessor products.

The case requires a Torx TX6 screwdriver to open.

See Saleae Logic Pro 8/Info for more details (such as lsusb -v output) about the device.

Note: Saleae Logic Pro 8 support in sigrok should be considered experimental for now. Only the logic analyzer parts are currently implemented (analog sampling is not).

Hardware

There are several testpoints on the underside of the PCB. It is not yet certain what these are for. There is no visible JTAG header.

Photos

Firmware

You can use the sigrok-fwextract-saleae-logic16 (sic!) tool to extract (from the "Logic" Linux binary; tested with the Saleae 1.2.10 software) the FX3 firmware and the FPGA bitstreams required for using the Saleae Logic Pro 16:

$ sigrok-fwextract-saleae-logic16 Logic
saved 5217 bytes to saleae-logic16-fx2.fw
saved 149516 bytes to saleae-logic16-fpga-18.bitstream
saved 149516 bytes to saleae-logic16-fpga-33.bitstream
saved 178702 bytes from 46 blobs to saleae-logicpro16-fx3.fw
saved 178702 bytes from 46 blobs to saleae-logicpro8-fx3.fw
saved 465028 bytes to saleae-logicpro16-fpga.bitstream
saved 341160 bytes to saleae-logicpro8-fpga.bitstream

Copy these files to the directory where your libsigrok installation expects them (usually /usr/local/share/sigrok-firmware) and they will be found and used automatically by the libsigrok saleae-logic-pro driver.

Note that sigrok-util (commit 20e302a2) only works Saleae Logic software up to 1.2.10 !