Hantek 6022BL

From sigrok
Revision as of 16:08, 9 April 2017 by Uwe Hermann (talk | contribs)
Jump to navigation Jump to search
Hantek 6022BL
Hantek 6022be mugshot.png
Status supported
Source code hantek-6xxx
Channels 2
Samplerate 48MHz
Analog bandwidth 20MHz
Vertical resolution 8bit
Triggers none (SW-only)
Input impedance 1MΩ‖25pF
Memory none
Display none
Connectivity USB
Website hantek.com

The Hantek 6022BL is a USB-based, 2-channel oscilloscope with an analog bandwidth of 20MS/s and 48MS/s sampling rate, and an 8-/16-channel logic analyzer with 24MHz sampling rate.

The device can either be used as oscilloscope or as logic analyzer, but not both at the same time. I.e., it is not a mixed-signal-oscilloscope (MSO).

Currently only the 8-channel logic analyzer mode is supported.

See Hantek 6022BL/Info for more details (such as lsusb -v output) about the device.

Hardware

The device has a "H/P" button. Depending on whether or not it's pressed it comes up with different USB VID/PIDs:

Discovered connections:

  • U2 is the Cypress FX2 controller, U4 is the '245 input buffer for digital probes, U8 is the ADC for two analog channels
  • FX2 PB and PD are connected to 16 lines of input data (shared among the digital buffer and the ADC output)
  • FX2 PA7 (pin 74) is directly connected to the digital buffer's OE signals (pins 25 and 48, low active, both 8bit groups share the signal) as well as DIR (pins 1 and 24)
  • FX2 PA7 is also connected to the ADC's S1 signal (pin 8, via two discrete inverters with R37, Q2, R13, Q1), S2 (pin 9) is tied to GND
  • according to the ADC datasheet (table 4), low/high signals on S1 and low on S2 result in either "standby mode" or "normal operation", respectively
  • with the digital buffer's OE signal being low active, low/high results in "active" and "tristate", respectively
  • this means: PA7 selects between digital (low) and analog (high) data paths, data is always at ports PB and PD, and either carries 16 digital channels, or two eight bit analog channels (TODO: work out the mapping of PB/PD bits to channel numbers)
    • FX2 -> U4
      • PD0 -> 2A1
      • ...
      • PD7 -> 2A8
      • PB0 -> 1A7
      • ...
      • PB7 -> 1A8
  • the benefit of "variable DIR" in the digital buffer is questionable, since it shares the signal with OE and for high levels the output is high-Z anyway -- so the ADC output is _not_ routed to digital pins when PA7 is high, not tying DIR to a fixed level is pointless(?)
  • six PA lines of the FX2 are connected to three lines per analog channel each (4051 mux chips in the BNC to ADC path) for attenuation / gain control:
    • FX2 -> U6:
      • PA1 -> S0
      • PA2 -> S1
      • PA3 -> S2
    • FX2 -> U10:
      • PA4 -> S0
      • PA5 -> S1
      • PA6 -> S2
  • The LED is connected to PC0 and PC1
  • The CAL is connected to PC2

Photos

Protocol

See Hantek 6022BE#Protocol.

When the "H/P" button is not pressed, the device can be used as 8-channel 24MHz logic analyzer via fx2lafw out of the box (using the fx2lafw protocol).

Firmware

See Hantek 6022BE#Firmware.

Resources