Chroma 62000P series
Revision as of 00:48, 17 May 2015 by Mrnuke (talk | contribs) (→Current limit vs max setable current)
Status | in progress |
---|---|
Source code | scpi-pps |
Channels | 1 |
Voltage/current (CH1) | 0-100V / 0-100A |
Connectivity | USBTMC, RS232, LXI or GPIB optional |
Website | chromaate.com |
Protocol
LIST Program example
PROG:SEL 1 PROG:MODE LIST PROG:ADD 1 PROG:SEQ:SEL 1 PROG:SEQ 0,40,10,25,INF,0,0.100 # Type AUTO, 40V, 10V/s, 25A, INF A/s, TTL output, 100ms PROG:SAVE # Optional PROG:RUN ON
Current limit vs max settable current
- ":SOUR:CURR" Set maximum output current (CC mode threshold)
- ":SOUR:CURR:LIM:HIGH" Limit the maximum current setting that device will accept