Difference between revisions of "Victor 70C/Info"
Jump to navigation
Jump to search
Uwe Hermann (talk | contribs) m |
Uwe Hermann (talk | contribs) m |
||
Line 38: | Line 38: | ||
bInterfaceClass 3 '''Human Interface Device''' | bInterfaceClass 3 '''Human Interface Device''' | ||
bInterfaceSubClass 1 '''Boot Interface Subclass''' | bInterfaceSubClass 1 '''Boot Interface Subclass''' | ||
bInterfaceProtocol 0 None | bInterfaceProtocol 0 '''None''' | ||
iInterface 2 '''VICTOR Multimeter''' | iInterface 2 '''VICTOR Multimeter''' | ||
HID Device Descriptor: | HID Device Descriptor: | ||
Line 59: | Line 59: | ||
Item(Global): Logical Minimum, data= [ 0x80 ] 128 | Item(Global): Logical Minimum, data= [ 0x80 ] 128 | ||
Item(Global): Logical Maximum, data= [ 0x7f ] 127 | Item(Global): Logical Maximum, data= [ 0x7f ] 127 | ||
Item(Global): Report Size, data= [ 0x08 ] 8 | Item(Global): Report Size, data= [ 0x08 ] '''8''' | ||
Item(Global): Report Count, data= [ 0x0e ] 14 | Item(Global): Report Count, data= [ 0x0e ] '''14''' | ||
Item(Main ): Input, data= [ 0x02 ] 2 | Item(Main ): '''Input''', data= [ 0x02 ] 2 | ||
Data Variable Absolute No_Wrap Linear | Data Variable Absolute No_Wrap Linear | ||
Preferred_State No_Null_Position Non_Volatile Bitfield | Preferred_State No_Null_Position Non_Volatile Bitfield | ||
Line 68: | Line 68: | ||
bLength 7 | bLength 7 | ||
bDescriptorType 5 | bDescriptorType 5 | ||
bEndpointAddress 0x81 EP 1 IN | bEndpointAddress 0x81 '''EP 1 IN''' | ||
bmAttributes 3 | bmAttributes 3 | ||
Transfer Type Interrupt | Transfer Type '''Interrupt''' | ||
Synch Type None | Synch Type None | ||
Usage Type Data | Usage Type Data |
Revision as of 14:25, 9 September 2012
lsusb
$ lsusb -v -d 1244:d237 Bus 001 Device 090: ID 1244:d237 Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB 1.10 bDeviceClass 0 (Defined at Interface level) bDeviceSubClass 0 bDeviceProtocol 0 bMaxPacketSize0 8 idVendor 0x1244 idProduct 0xd237 bcdDevice 1.00 iManufacturer 1 Shenzhen VICTOR HI- TECH CO. LTD. iProduct 2 VICTOR Multimeter iSerial 0 bNumConfigurations 1 Configuration Descriptor: bLength 9 bDescriptorType 2 wTotalLength 34 bNumInterfaces 1 bConfigurationValue 1 iConfiguration 0 bmAttributes 0xa0 (Bus Powered) Remote Wakeup MaxPower 100mA Interface Descriptor: bLength 9 bDescriptorType 4 bInterfaceNumber 0 bAlternateSetting 0 bNumEndpoints 1 bInterfaceClass 3 Human Interface Device bInterfaceSubClass 1 Boot Interface Subclass bInterfaceProtocol 0 None iInterface 2 VICTOR Multimeter HID Device Descriptor: bLength 9 bDescriptorType 33 bcdHID 1.10 bCountryCode 0 Not supported bNumDescriptors 1 bDescriptorType 34 Report wDescriptorLength 19 Report Descriptor: (length is 19) Item(Global): Usage Page, data= [ 0x01 ] 1 Generic Desktop Controls Item(Local ): Usage, data= [ 0x00 ] 0 Undefined Item(Main ): Collection, data= [ 0x01 ] 1 Application Item(Local ): Usage, data= [ 0x00 ] 0 Undefined Item(Global): Logical Minimum, data= [ 0x80 ] 128 Item(Global): Logical Maximum, data= [ 0x7f ] 127 Item(Global): Report Size, data= [ 0x08 ] 8 Item(Global): Report Count, data= [ 0x0e ] 14 Item(Main ): Input, data= [ 0x02 ] 2 Data Variable Absolute No_Wrap Linear Preferred_State No_Null_Position Non_Volatile Bitfield Item(Main ): End Collection, data=none Endpoint Descriptor: bLength 7 bDescriptorType 5 bEndpointAddress 0x81 EP 1 IN bmAttributes 3 Transfer Type Interrupt Synch Type None Usage Type Data wMaxPacketSize 0x0008 1x 8 bytes bInterval 10 Device Status: 0x0000 (Bus Powered)