Difference between revisions of "MASTECH MS2115B"
Jump to navigation
Jump to search
Uwe Hermann (talk | contribs) (MASTECH MS2115B is supported.) |
(Link to mastech changed to AC / DC clamp meters) |
||
Line 9: | Line 9: | ||
| measurements = voltage, current, resistance, capacitance, frequency, duty cycle, diode, continuity | | measurements = voltage, current, resistance, capacitance, frequency, duty cycle, diode, continuity | ||
| features = autorange, true-rms, data hold, min/max, relative, inrush, bargraph, backlight, ncv | | features = autorange, true-rms, data hold, min/max, relative, inrush, bargraph, backlight, ncv | ||
| website = [http://www.mastech-group.com/products.php?cate= | | website = [http://www.mastech-group.com/products.php?cate=97 mastech-group.com] | ||
}} | }} | ||
Revision as of 17:49, 1 May 2019
Status | supported |
---|---|
Source code | serial-dmm |
Counts | 6000 |
IEC 61010-1 | CAT III (1000V) / CAT IV (600V) |
Connectivity | USB/serial |
Measurements | voltage, current, resistance, capacitance, frequency, duty cycle, diode, continuity |
Features | autorange, true-rms, data hold, min/max, relative, inrush, bargraph, backlight, ncv |
Website | mastech-group.com |
The MASTECH MS2115B is a 6000 counts, CAT III (1000V) / CAT IV (600V) handheld dual display digital clamp meter with USB connectivity.
See MASTECH MS2115B/Info for more details (such as lsusb -v output) about the device.
Hardware
- Silicon Labs CP2102 USB to UART bridge controller
- Cyrustek ES51970 DMM analog front end with inrush (datasheet)
Photos
Protocol
The chip periodically sends 9-byte packets at 1200 baud, 8n1. There is no checksum or CRC in the packet.