Difference between revisions of "Voltcraft 18220"

From sigrok
Jump to navigation Jump to search
(Set status to Planned.)
 
Line 2: Line 2:
<!-- | image              = [[File:Conrad digi 35 cpu logo.png|180px]] -->
<!-- | image              = [[File:Conrad digi 35 cpu logo.png|180px]] -->
| name                = Voltcraft 18220
| name                = Voltcraft 18220
| status              = in progress
| status              = planned
| source_code_dir    =  
| source_code_dir    =  
| channels            = 1
| channels            = 1
Line 19: Line 19:
It was sold by Conrad Elektronik as article 512923.
It was sold by Conrad Elektronik as article 512923.


= Hardware =
== Hardware ==


* Output protection against reverse current: Max. 1 A!
* Output protection against reverse current: Max. 1 A!


= Photos =
== Photos ==
 
<gallery>
<gallery>
</gallery>
</gallery>


= Protocol =
== Protocol ==


ASCII based.
ASCII based.


= Manual Operation =
== Manual Operation ==
== Status on power up ==
 
=== Status on power up ===
 
The output is disabled. Voltage and current are set to the value on previous power-off. A small negative (!) voltage can be measured while output is off.   
The output is disabled. Voltage and current are set to the value on previous power-off. A small negative (!) voltage can be measured while output is off.   


== Output Control ==
=== Output Control ===
 
* On: Keep button ''VOLT/AMPERE'' pressed, press ▲.
* On: Keep button ''VOLT/AMPERE'' pressed, press ▲.
* Off: Keep button ''VOLT/AMPERE'' pressed, press ▼.
* Off: Keep button ''VOLT/AMPERE'' pressed, press ▼.


== Voltage Control ==
=== Voltage Control ===
 
* If LED ''Volt'' is not on, press button ''VOLT/AMPERE''.
* If LED ''Volt'' is not on, press button ''VOLT/AMPERE''.
* Press ▲ to increase voltage by 50 mV.
* Press ▲ to increase voltage by 50 mV.
* Press ▼ to decrease voltage by 50 mV.
* Press ▼ to decrease voltage by 50 mV.


== Current Control ==
=== Current Control ===
 
* If LED ''AMPERE'' is not on, press button ''VOLT/AMPERE''.
* If LED ''AMPERE'' is not on, press button ''VOLT/AMPERE''.
* Press ▲ to increase current limit by 100 mA.
* Press ▲ to increase current limit by 100 mA.
Line 50: Line 56:
* To display current current limit, shorten output externally.  
* To display current current limit, shorten output externally.  


= Remote Operation =
== Remote Operation ==


The sigrok driver for this device will be named ''voltcraft-18220''.
The sigrok driver for this device will be named ''voltcraft-18220''.


= Resources =
== Resources ==
 
* Manual (German) available from [http://www.conrad.de Conrad Elektronik] via customer support.
* Manual (German) available from [http://www.conrad.de Conrad Elektronik] via customer support.
* http://software.freepage.de/hmueller/pilot/SNT/ Control software for PalmPilot
* http://software.freepage.de/hmueller/pilot/SNT/ Control software for PalmPilot


= See also =
== See also ==
 
* [[Programmable power supply]]
* [[Programmable power supply]]
* [[Power supply comparison]]
* [[Power supply comparison]]


[[Category:Device]]
[[Category:Device]]
[[Category:Power supply]]
[[Category:Power supply]]
[[Category:In progress]]
[[Category:Planned]]

Latest revision as of 19:48, 20 December 2016

Voltcraft 18220
Status planned
Channels 1
Voltage/current (CH1) 0-40V / 0-5A
Connectivity RS232
Features settable values, settable output.

Please note: This page is a work in progress, more to come.

The Conrad Voltcraft 18220 is a one-channel digitally-controlled laboratory power supply with RS-232 connectivity. It came onto the market in about 1996. It was sold by Conrad Elektronik as article 512923.

Hardware

  • Output protection against reverse current: Max. 1 A!

Photos

Protocol

ASCII based.

Manual Operation

Status on power up

The output is disabled. Voltage and current are set to the value on previous power-off. A small negative (!) voltage can be measured while output is off.

Output Control

  • On: Keep button VOLT/AMPERE pressed, press ▲.
  • Off: Keep button VOLT/AMPERE pressed, press ▼.

Voltage Control

  • If LED Volt is not on, press button VOLT/AMPERE.
  • Press ▲ to increase voltage by 50 mV.
  • Press ▼ to decrease voltage by 50 mV.

Current Control

  • If LED AMPERE is not on, press button VOLT/AMPERE.
  • Press ▲ to increase current limit by 100 mA.
  • Press ▼ to decrease current limit by 100 mA.
  • To display current current limit, shorten output externally.

Remote Operation

The sigrok driver for this device will be named voltcraft-18220.