Difference between revisions of "Manson HCS-3xxx series"
Uwe Hermann (talk | contribs) m (→Protocol) |
Uwe Hermann (talk | contribs) |
||
Line 9: | Line 9: | ||
| channel3 = | | channel3 = | ||
| channel4 = | | channel4 = | ||
| connectivity = USB | | connectivity = USB/serial | ||
| features = programmable presets, cycling functionality | | features = programmable presets, cycling functionality | ||
| website = [http://www.manson.com.hk/products/category/dc_power_supplies manson.com.hk] | | website = [http://www.manson.com.hk/products/category/dc_power_supplies manson.com.hk] |
Revision as of 09:56, 13 October 2014
Status | supported |
---|---|
Source code | manson-hcs-3xxx |
Channels | 1 |
Voltage/current (CH1) | various |
Connectivity | USB/serial |
Features | programmable presets, cycling functionality |
Website | manson.com.hk |
The Manson HCS-3xxx series are 1 channel switch-mode programmable power supplies with USB/serial connectivity.
Devices
Manson | Conrad OEM | Peaktech OEM | Voltage range | Current range | Power | Comments |
---|---|---|---|---|---|---|
HCS-3100 | PPS-11810 | 1-18 V | 0-10 A | 180 W | ||
HCS-3102 | PPS-11360 | 1-36 V | 0-5 A | 180 W | ||
HCS-3104 | PPS-11603 | 1-60 V | 0-2.5 A | 150 W | ||
HCS-3150 | - | 1-18 V | 0-15 A | 270 W | ||
HCS-3200 | PPS-13610 | 1-18 V | 0-20 A | 360 W | ||
HCS-3202 | PPS-16005 | 1-36 V | 0-10 A | 360 W | ||
HCS-3204 | PPS-11815 | 1-60 V | 0-5 A | 300 W | ||
HCS-3300-USB | - | - | 1-16 V | 0-30 A | 480 W | |
HCS-3302-USB | - | - | 1-32 V | 0-15 A | 480 W | |
HCS-3304-USB | - | - | 1-60 V | 0-8 A | 480 W | |
HCS-3400-USB | - | PeakTech 1565 | 1-16 V | 0-40 A | 600 W | |
HCS-3402-USB | - | PeakTech 1575 | 1-32 V | 0-20 A | 600 W? | |
HCS-3404-USB | - | - | 1-60 V | 0-10 A | 600 W | |
HCS-3600-USB | - | PeakTech 1580 | 1-16 V | 0-60 A | 750 W | |
HCS-3602-USB | - | PeakTech 1580 | 1-30 V | 0-30 A | 900 W | |
HCS-3604-USB | - | - | 1-60 V | 0-15 A | 900 W |
The voltage and current specs are rounded values from the manufacturer's specs. The devices might allow slightly higher values for voltage and current. The exact values read from the devices are available by listing the config keys SR_CONF_OUTPUT_VOLTAGE_MAX and SR_CONF_OUTPUT_CURRENT_MAX.
The devices linked above are supported. The other devices might work, but are untested. If you have one of the unsupported devices and can test it, please contact Matthias.
Some other device series by the same manufacturer exist that use a different communication protocol.
Config keys
Function | Target | Parameters | Comments |
---|---|---|---|
SR_CONF_OUTPUT_ENABLED | Device | Boolean on/off | Get: Query output status. Set: Switch output on or off. Power-on default is on. |
SR_CONF_OUTPUT_VOLTAGE | Device | Double | Get: Query output voltage. Updated only if sampling is active! |
SR_CONF_OUTPUT_VOLTAGE_MAX | Device | Double | List: Get 3-tuple (min, max, step) for output voltage range. Get: Get output voltage limit. Set: Set output voltage limit. |
SR_CONF_OUTPUT_CURRENT | Device | Double | Get: Query output current. Updated only if sampling is active! |
SR_CONF_OUTPUT_CURRENT_MAX | Device | Double | List: Get 3-tuple (min, max, step) for output current range. Get: Get output current limit. Set: Set output current limit. |
See also Programmable power supply!
Protocol
The devices uses an ASCII-based protocol over a USB-to-serial link.
All commands and replies end with a carriage return (\r) character.
Some versions of the protocol description in manuals are incomplete or even erroneous.
Command | Reply | Description | Comments |
---|---|---|---|
GMOD\r | 3204\rOK\r | Query model | Four-digit model code, e.g. 3202 for the HCS-3202. |
GETD\r | VVVVCCCCS\rOK\r | Query displayed voltage, current and mode. | Four-digit voltage, e.g. 12.34; four-digit current, e.g. 12.34; status 0=constant voltage, 1=constant current. |
SOUTn\r | OK\r | Disable output | Output on=0 (power-on default), off=1 |
SESS\r | OK\r | Disable keyboard | Seems to time out after about 5 seconds. |
ENDS\r | OK\r | Enable keyboard | When disabled with SESS. |
VOLTnnn\r | OK\r | Set voltage to nn.n. | |
CURRnnn\r | OK\r | Set current to nn.n or n.nn (model-dependent!). |
Resources
- Vendor control software (HCS_PC_software_v0_9.rar)
- Vendor Labview driver (HCS_labview_high_current_v0_1.rar)
- reinhardweiss.de: Manson HCS-3204 info (most of it also applies to the other devices in the series)
- goughlui.com: Review: Manson HCS-3102 1-36v/0-5A Switch-Mode Benchtop Power Supply (most of it also applies to the other devices in the series)
- ELV: HCS-3200/3202/3204 manual (contains some more commands than the manufacturer's docs)