Difference between revisions of "IEEE-488"

From sigrok
Jump to navigation Jump to search
Line 6: Line 6:
* '''IEEE-488.2:''' Formats and common commands.
* '''IEEE-488.2:''' Formats and common commands.
* '''SCPI:''' Standard commands, built on top of IEEE-488.2. The standard is available [http://www.ivifoundation.org/docs/scpi-99.pdf here].
* '''SCPI:''' Standard commands, built on top of IEEE-488.2. The standard is available [http://www.ivifoundation.org/docs/scpi-99.pdf here].
* '''USBTMC:''' The USB TMC device class, standard is available [http://www.usb.org/developers/devclass_docs/USBTMC_1_006a.zip here].
* '''USBTMC:''' The USB TMC device class, standard is available [https://www.usb.org/document-library/test-measurement-class-specification here].
* '''LXI:''' The LAN eXtensions fo Instrumentation, standard is available [http://www.lxistandard.org/Documents/Specifications/LXI%20Device%20Specification%202011%20rev%201.4.pdf here].
* '''LXI:''' The LAN eXtensions fo Instrumentation, standard is available [http://www.lxistandard.org/Documents/Specifications/LXI%20Device%20Specification%202011%20rev%201.4.pdf here].


Line 30: Line 30:
| SCPI
| SCPI
| bgcolor="lime" align="center" | supported
| bgcolor="lime" align="center" | supported
| style="vertical-align: top" | Only serial devices are currently supported.
| style="vertical-align: top" | Various transports are supported: serial, tcp, usbtmc, vxi, visa, libgpib.
|- bgcolor="#eeeeee"
|- bgcolor="#eeeeee"
| IEEE-488.2
| IEEE-488.2
Line 40: Line 40:
== Devices ==
== Devices ==


{| width="100%" border="0" style="vertical-align: top"
Various GPIB/USBTMC devices are supported, see [[Supported hardware]] for details.
|- bgcolor="#6699ff"
! width="30%" | Device
! width="20%" | Status
! Comments
 
|- bgcolor="#dddddd"
| [[Agilent MSO7104A]]
| bgcolor="orange" align="center" | planned
| style="vertical-align: top" | USB-TMC. Probably same protocol on various Agilent MSO7xxxx series scopes.
 
|- bgcolor="#dddddd"
| [[Hameg HMO1524]]
| bgcolor="lime" align="center" | supported
| style="vertical-align: top" |
 
|- bgcolor="#dddddd"
| [[Yokogawa DLM2000 series]]
| bgcolor="lime" align="center" | supported
| style="vertical-align: top" | USB-TMC works, LXI needs verification
 
|}
 
See also: [[Supported hardware]].


== Resources ==
== Resources ==

Revision as of 15:35, 14 December 2019

IEEE-488, also known as GPIB or HP-IB, comprises a set of standards which allows various test and measurement gear to be controlled and queried remotely.

The following standards are involved:

  • IEEE-488.1: Mechanical, electrical and basic protocol.
  • IEEE-488.2: Formats and common commands.
  • SCPI: Standard commands, built on top of IEEE-488.2. The standard is available here.
  • USBTMC: The USB TMC device class, standard is available here.
  • LXI: The LAN eXtensions fo Instrumentation, standard is available here.

While IEEE-488.1 defines the "Centronix-style" parallel connector, the other standards are in fact seen over other types of connections: RS-232, DB25 parallel connectors, and so on.

sigrok aims to support all of this: all of the command sets, on any device supporting them, across any interface.

GPIB PC interfaces

See GPIB interface comparison for a list of GPIB interfaces we know about.

See Supported hardware#GPIB_interfaces for the list of devices planned/supported in sigrok.

Command sets

Command set Status Comments
SCPI supported Various transports are supported: serial, tcp, usbtmc, vxi, visa, libgpib.
IEEE-488.2 not yet supported Standard document needed

Devices

Various GPIB/USBTMC devices are supported, see Supported hardware for details.

Resources