Difference between revisions of "Manson HCS-3xxx series"

From sigrok
Jump to navigation Jump to search
m
Line 19: Line 19:


{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable"
{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable"
|-
|-
!Manson
!Manson
!Conrad OEM
!Conrad OEM
!Peaktech OEM  
!Peaktech OEM  
!Voltage Range
!Voltage range
!Current Range
!Current range
!Power
!Power
!Remarks
!Comments


|-
|-
Line 175: Line 174:
|}
|}


The voltage and current specs are rounded values from the manufacturer's specs. The devices might allow slightly higher values for voltage and current. The exact values read from the devices are available by listing the config keys SR_CONF_OUTPUT_VOLTAGE_MAX and ...CURRENT_MAX.
The voltage and current specs are rounded values from the manufacturer's specs. The devices might allow slightly higher values for voltage and current. The exact values read from the devices are available by listing the config keys '''SR_CONF_OUTPUT_VOLTAGE_MAX''' and '''SR_CONF_OUTPUT_CURRENT_MAX'''.


The devices linked above are supported. The other devices might work, but are untested. If you have one of the unsupported devices and can test it, please contact [[User:Matthias_Heidbrink|Matthias]].
The devices linked above are supported. The other devices might work, but are untested. If you have one of the unsupported devices and can test it, please contact [[User:Matthias_Heidbrink|Matthias]].


Some other device series by the same manufacturer exist that use a different communication protocol.
Some other device series by the same manufacturer exist that use a different communication protocol.
Line 188: Line 187:
! Target
! Target
! Parameters
! Parameters
! Comment
! Comments


|-
|-
Line 206: Line 205:
| Device
| Device
| Double
| Double
| | List: Get 3-tupel (min, max, step) for output voltage range. Get: Get output voltage limit. Set: Set output voltage limit.
| List: Get 3-tuple (min, max, step) for output voltage range. Get: Get output voltage limit. Set: Set output voltage limit.


|-
|-
Line 218: Line 217:
| Device
| Device
| Double
| Double
| List: Get 3-tupel (min, max, step) for output current range. Get: Get output current limit. Set: Set output current limit.  
| List: Get 3-tuple (min, max, step) for output current range. Get: Get output current limit. Set: Set output current limit.  


|}
|}
Line 225: Line 224:


== Protocol ==
== Protocol ==
ASCII based over USB-to-serial.


Some versions of the protocol description in manuals are incomplete or even erroneous.  
The devices uses an ASCII-based protocol over a USB-to-serial link.
 
All commands and replies end with a newline ('''\n''') character.
 
Some versions of the protocol description in manuals are incomplete or even erroneous.


{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable"
{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable"
|-
|-
!Command  
!Command  
!Reply
!Reply
!Description
!Description
!Remarks
!Comments


|-
|-
Line 241: Line 242:
| 3204\r<br/>OK\r
| 3204\r<br/>OK\r
| Query model
| Query model
| Four-digit model code, e.g. <i>3202</i> for <i>HCS-3202</i>.
| Four-digit model code, e.g. ''3202'' for the [[Manson HCS-3202|HCS-3202]].


|-  
|-  
Line 250: Line 251:


|-  
|-  
| SOUT<i>n</i>\r
| SOUT''n''\r
| OK\r
| OK\r
| Disable output
| Disable output
Line 268: Line 269:


|-  
|-  
| VOLT<i>nnn</i>\r
| VOLT''nnn''\r
| OK\r
| OK\r
| Set voltage to nn.n.
| Set voltage to nn.n.
Line 274: Line 275:


|-  
|-  
| CURR<i>nnn</i>\r
| CURR''nnn''\r
| OK\r
| OK\r
| Set current to nn.n or n.nn (model-dependant!).
| Set current to nn.n or n.nn (model-dependent!).
|  
|  



Revision as of 21:44, 1 September 2014

Manson HCS-3xxx
Manson hcs3202.png
Status supported
Source code manson-hcs-3xxx
Channels 1
Voltage/current (CH1) various
Connectivity USB
Features programmable presets, cycling functionality
Website manson.com.hk

The Manson HCS-3xxx series are 1 channel switch-mode programmable power supplies with USB/serial connectivity.

Devices

Manson Conrad OEM Peaktech OEM Voltage range Current range Power Comments
HCS-3100 PPS-11810 1-18 V 0-10 A 180 W
HCS-3102 PPS-11360 1-36 V 0-5 A 180 W
HCS-3104 PPS-11603 1-60 V 0-2.5 A 150 W
HCS-3150 - 1-18 V 0-15 A 270 W
HCS-3200 PPS-13610 1-18 V 0-20 A 360 W
HCS-3202 PPS-16005 1-36 V 0-10 A 360 W
HCS-3204 PPS-11815 1-60 V 0-5 A 300 W
HCS-3300-USB - - 1-16 V 0-30 A 480 W
HCS-3302-USB - - 1-32 V 0-15 A 480 W
HCS-3304-USB - - 1-60 V 0-8 A 480 W
HCS-3400-USB - PeakTech 1565 1-16 V 0-40 A 600 W
HCS-3402-USB - PeakTech 1575 1-32 V 0-20 A 600 W?
HCS-3404-USB - - 1-60 V 0-10 A 600 W
HCS-3600-USB - PeakTech 1580 1-16 V 0-60 A 750 W
HCS-3602-USB - PeakTech 1580 1-30 V 0-30 A 900 W
HCS-3604-USB - - 1-60 V 0-15 A 900 W

The voltage and current specs are rounded values from the manufacturer's specs. The devices might allow slightly higher values for voltage and current. The exact values read from the devices are available by listing the config keys SR_CONF_OUTPUT_VOLTAGE_MAX and SR_CONF_OUTPUT_CURRENT_MAX.

The devices linked above are supported. The other devices might work, but are untested. If you have one of the unsupported devices and can test it, please contact Matthias.

Some other device series by the same manufacturer exist that use a different communication protocol.

Config keys

Function Target Parameters Comments
SR_CONF_OUTPUT_ENABLED Device Boolean on/off Get: Query output status. Set: Switch output on or off. Power-on default is on.
SR_CONF_OUTPUT_VOLTAGE Device Double Get: Query output voltage. Updated only if sampling is active!
SR_CONF_OUTPUT_VOLTAGE_MAX Device Double List: Get 3-tuple (min, max, step) for output voltage range. Get: Get output voltage limit. Set: Set output voltage limit.
SR_CONF_OUTPUT_CURRENT Device Double Get: Query output current. Updated only if sampling is active!
SR_CONF_OUTPUT_CURRENT_MAX Device Double List: Get 3-tuple (min, max, step) for output current range. Get: Get output current limit. Set: Set output current limit.

See also Programmable power supply!

Protocol

The devices uses an ASCII-based protocol over a USB-to-serial link.

All commands and replies end with a newline (\n) character.

Some versions of the protocol description in manuals are incomplete or even erroneous.

Command Reply Description Comments
GMOD\r 3204\r
OK\r
Query model Four-digit model code, e.g. 3202 for the HCS-3202.
GETD\r VVVVCCCCS\r
OK\r
Query displayed voltage, current and mode. Four-digit voltage, e.g. 12.34; four-digit current, e.g. 12.34; status 0=constant voltage, 1=constant current.
SOUTn\r OK\r Disable output Output on=0 (power-on default), off=1
SESS\r OK\r Disable keyboard Seems to time out after about 5 seconds.
ENDS\r OK\r Enable keyboard When disabled with SESS.
VOLTnnn\r OK\r Set voltage to nn.n.
CURRnnn\r OK\r Set current to nn.n or n.nn (model-dependent!).
... ... ... Protocol description incomplete so far.

Resources