Difference between revisions of "RadioShack 22-812"
(→Photos) |
|||
Line 8: | Line 8: | ||
| connectivity = RS232 (standard DB9 connector) | | connectivity = RS232 (standard DB9 connector) | ||
| measurements = voltage, temperature, current, resistance, capacitance, continuity, diode, logic, frequency, hFE, duty cycle, pulse width | | measurements = voltage, temperature, current, resistance, capacitance, continuity, diode, logic, frequency, hFE, duty cycle, pulse width | ||
| features = autorange, data hold, min/max | | features = autorange, data hold, min/max, dBm (600Ω) | ||
| website = [https://www.radioshack.com/search/softwareResults.jsp?kw=22-812 radioshack.com] | | website = [https://www.radioshack.com/search/softwareResults.jsp?kw=22-812 radioshack.com] | ||
}} | }} |
Revision as of 05:31, 15 December 2012
Status | supported |
---|---|
Source code | serial-dmm |
Counts | 4000 |
IEC 61010-1 | CAT II (600V) |
Connectivity | RS232 (standard DB9 connector) |
Measurements | voltage, temperature, current, resistance, capacitance, continuity, diode, logic, frequency, hFE, duty cycle, pulse width |
Features | autorange, data hold, min/max, dBm (600Ω) |
Website | radioshack.com |
The RadioShack 22-812 is a 4000 counts, CAT II (600V) handheld digital multimeter with RS-232 connectivity.
It is no longer sold under this part number, and for a while, it appeared to have been discontinued. RadioShack does sell a visually identical multimeter, the RadioShack 22-039. It is not yet clear if the 22-039 is the same device as the 22-812.
Hardware
The microcontroller is an unidentifiable plastic blob.
This devices has a standard DB-9 connector at the top, and does not require a special adapter cable. The RS-232 transmitter is optically insulated from the rest of the device. The transmitter uses a separate PCB, integrated into the multimeter's housing. The RS-232 module is powered from the serial port.
Photos
Protocol
The device periodically sends 9-byte packets at 4800 baud, 8n1. The packet includes a mode indicator, payload and checksum. The payload is a 1-1 mapping of the LCD segments.
Packet structure
Byte | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
---|---|---|---|---|---|---|---|---|
0 | Mode | |||||||
1 | Hz | Ohms | k | M | F | A | V | m |
2 | u | n | dBm | s | % | hFE | REL | MIN |
3 | 4D | 4C | 4G | 4B | DP3 | 4E | 4F | 4A |
4 | 3D | 3C | 3G | 3B | DP2 | 3E | 3F | 3A |
5 | 2D | 2C | 2G | 2B | DP1 | 2E | 2F | 2A |
6 | 1D | 1C | 1G | 1B | MAX | 1E | 1F | 1A |
7 | Beep | Diode | Bat | Hold | - | ~ | RS232 | Auto |
8 | Checksum |
Segment lettering
A | ||
F | B | |
G | ||
E | C | |
D |
Mode byte
Value | Meaning |
---|---|
0 | DC V |
1 | AC V |
2 | DC uA |
3 | DC mA |
4 | DC A |
5 | AC uA |
6 | AC mA |
7 | AC A |
8 | Ohm |
9 | Capacitance |
10 | Hz (dial set to Hz) |
11 | Hz (dial set to DCV) |
12 | Hz (dial set to mA/A) |
13 | Duty cycle (dial set to Hz) |
14 | Duty cycle (dial set to DCV) |
15 | Duty cycle (dial set to mA/A) |
16 | Pulse width (dial set to Hz) |
17 | Pulse width (dial set to DCV) |
18 | Pulse width (dial set to mA/A) |
19 | Diode |
20 | Continuity (beep) |
21 | hFE |
22 | LOGIC |
23 | dBm |
24 | (Unknown) |
25 | Temp |
Resources
- rs22812.py project page (Python interface to RadioShack 22-812 DMM)
- RadioShack 22-812 user manual