Difference between revisions of "Pico Technology PicoScope 3206/Info"

From sigrok
Jump to navigation Jump to search
(Created page with "<small> Bus 001 Device 035: ID 0ce9:1001 '''pico Technology PicoScope3204''' Device Descriptor: bLength 18 bDescriptorType 1 bcdUSB ...")
 
Line 1: Line 1:
__FORCETOC__
== Before firmware upload ==
This is a standard FX2 endpoint set with VID:PID loaded from EEPROM.
<small>
<small>
  Bus 001 Device 035: ID 0ce9:1001 '''pico Technology PicoScope3204'''
  Bus 001 Device 035: ID 0ce9:1001 '''pico Technology PicoScope3204'''
Line 253: Line 256:
   bDeviceSubClass      255 Vendor Specific Subclass
   bDeviceSubClass      255 Vendor Specific Subclass
   bDeviceProtocol      255 Vendor Specific Protocol
   bDeviceProtocol      255 Vendor Specific Protocol
  bMaxPacketSize0        64
  bNumConfigurations      1
Device Status:    0x0000
  (Bus Powered)
</small>
== After firmware upload ==
<small>
Bus 001 Device 036: ID 0ce9:1001 '''pico Technology PicoScope3204'''
Device Descriptor:
  bLength                18
  bDescriptorType        1
  bcdUSB              2.00
  bDeviceClass            0 (Defined at Interface level)
  bDeviceSubClass        0
  bDeviceProtocol        0
  bMaxPacketSize0        64
  idVendor          0x0ce9 pico Technology
  idProduct          0x1001 PicoScope3204
  bcdDevice            0.00
  iManufacturer          1 Pico
  iProduct                2 PicoScope 3000
  iSerial                0
  bNumConfigurations      1
  Configuration Descriptor:
    bLength                9
    bDescriptorType        2
    wTotalLength          32
    bNumInterfaces          1
    bConfigurationValue    1
    iConfiguration          0
    bmAttributes        0x80
      (Bus Powered)
    MaxPower              500mA
    Interface Descriptor:
      bLength                9
      bDescriptorType        4
      bInterfaceNumber        0
      bAlternateSetting      0
      bNumEndpoints          2
      bInterfaceClass      255 Vendor Specific Class
      bInterfaceSubClass      0
      bInterfaceProtocol      0
      iInterface              0
      Endpoint Descriptor:
        bLength                7
        bDescriptorType        5
        bEndpointAddress    0x04  EP 4 OUT
        bmAttributes            2
          Transfer Type            Bulk
          Synch Type              None
          Usage Type              Data
        wMaxPacketSize    0x0200  1x 512 bytes
        bInterval              0
      Endpoint Descriptor:
        bLength                7
        bDescriptorType        5
        bEndpointAddress    0x88  EP 8 IN
        bmAttributes            2
          Transfer Type            Bulk
          Synch Type              None
          Usage Type              Data
        wMaxPacketSize    0x0200  1x 512 bytes
        bInterval              0
Device Qualifier (for other device speed):
  bLength                10
  bDescriptorType        6
  bcdUSB              2.00
  bDeviceClass            0 (Defined at Interface level)
  bDeviceSubClass        0
  bDeviceProtocol        0
   bMaxPacketSize0        64
   bMaxPacketSize0        64
   bNumConfigurations      1
   bNumConfigurations      1

Revision as of 09:58, 29 September 2012

Before firmware upload

This is a standard FX2 endpoint set with VID:PID loaded from EEPROM.

Bus 001 Device 035: ID 0ce9:1001 pico Technology PicoScope3204
Device Descriptor:
 bLength                18
 bDescriptorType         1
 bcdUSB               2.00
 bDeviceClass          255 Vendor Specific Class
 bDeviceSubClass       255 Vendor Specific Subclass
 bDeviceProtocol       255 Vendor Specific Protocol
 bMaxPacketSize0        64
 idVendor           0x0ce9 pico Technology
 idProduct          0x1001 PicoScope3204
 bcdDevice            0.00
 iManufacturer           0 
 iProduct                0 
 iSerial                 0 
 bNumConfigurations      1
 Configuration Descriptor:
   bLength                 9
   bDescriptorType         2
   wTotalLength          171
   bNumInterfaces          1
   bConfigurationValue     1
   iConfiguration          0 
   bmAttributes         0x80
     (Bus Powered)
   MaxPower              100mA
   Interface Descriptor:
     bLength                 9
     bDescriptorType         4
     bInterfaceNumber        0
     bAlternateSetting       0
     bNumEndpoints           0
     bInterfaceClass       255 Vendor Specific Class
     bInterfaceSubClass    255 Vendor Specific Subclass
     bInterfaceProtocol    255 Vendor Specific Protocol
     iInterface              0 
   Interface Descriptor:
     bLength                 9
     bDescriptorType         4
     bInterfaceNumber        0
     bAlternateSetting       1
     bNumEndpoints           6
     bInterfaceClass       255 Vendor Specific Class
     bInterfaceSubClass    255 Vendor Specific Subclass
     bInterfaceProtocol    255 Vendor Specific Protocol
     iInterface              0 
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x01  EP 1 OUT
       bmAttributes            2
         Transfer Type            Bulk
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval               0
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x81  EP 1 IN
       bmAttributes            2
         Transfer Type            Bulk
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval               0
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x02  EP 2 OUT
       bmAttributes            2
         Transfer Type            Bulk
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval               0
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x04  EP 4 OUT
       bmAttributes            2
         Transfer Type            Bulk
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval               0
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x86  EP 6 IN
       bmAttributes            2
         Transfer Type            Bulk
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval               0
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x88  EP 8 IN
       bmAttributes            2
         Transfer Type            Bulk
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval               0
   Interface Descriptor:
     bLength                 9
     bDescriptorType         4
     bInterfaceNumber        0
     bAlternateSetting       2
     bNumEndpoints           6
     bInterfaceClass       255 Vendor Specific Class
     bInterfaceSubClass    255 Vendor Specific Subclass
     bInterfaceProtocol    255 Vendor Specific Protocol
     iInterface              0 
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x01  EP 1 OUT
       bmAttributes            3
         Transfer Type            Interrupt
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval              10
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x81  EP 1 IN
       bmAttributes            3
         Transfer Type            Interrupt
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval              10
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x02  EP 2 OUT
       bmAttributes            3
         Transfer Type            Interrupt
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval              10
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x04  EP 4 OUT
       bmAttributes            2
         Transfer Type            Bulk
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval               0
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x86  EP 6 IN
       bmAttributes            3
         Transfer Type            Interrupt
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval              10
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x88  EP 8 IN
       bmAttributes            2
         Transfer Type            Bulk
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval               0
   Interface Descriptor:
     bLength                 9
     bDescriptorType         4
     bInterfaceNumber        0
     bAlternateSetting       3
     bNumEndpoints           6
     bInterfaceClass       255 Vendor Specific Class
     bInterfaceSubClass    255 Vendor Specific Subclass
     bInterfaceProtocol    255 Vendor Specific Protocol
     iInterface              0 
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x01  EP 1 OUT
       bmAttributes            3
         Transfer Type            Interrupt
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval              10
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x81  EP 1 IN
       bmAttributes            3
         Transfer Type            Interrupt
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval              10
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x02  EP 2 OUT
       bmAttributes            1
         Transfer Type            Isochronous
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval               1
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x04  EP 4 OUT
       bmAttributes            2
         Transfer Type            Bulk
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval               0
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x86  EP 6 IN
       bmAttributes            1
         Transfer Type            Isochronous
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval               1
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x88  EP 8 IN
       bmAttributes            2
         Transfer Type            Bulk
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0040  1x 64 bytes
       bInterval               0
Device Qualifier (for other device speed):
 bLength                10
 bDescriptorType         6
 bcdUSB               2.00
 bDeviceClass          255 Vendor Specific Class
 bDeviceSubClass       255 Vendor Specific Subclass
 bDeviceProtocol       255 Vendor Specific Protocol
 bMaxPacketSize0        64
 bNumConfigurations      1
Device Status:     0x0000
 (Bus Powered)

After firmware upload

Bus 001 Device 036: ID 0ce9:1001 pico Technology PicoScope3204
Device Descriptor:
 bLength                18
 bDescriptorType         1
 bcdUSB               2.00
 bDeviceClass            0 (Defined at Interface level)
 bDeviceSubClass         0 
 bDeviceProtocol         0 
 bMaxPacketSize0        64
 idVendor           0x0ce9 pico Technology
 idProduct          0x1001 PicoScope3204
 bcdDevice            0.00
 iManufacturer           1 Pico
 iProduct                2 PicoScope 3000
 iSerial                 0 
 bNumConfigurations      1
 Configuration Descriptor:
   bLength                 9
   bDescriptorType         2
   wTotalLength           32
   bNumInterfaces          1
   bConfigurationValue     1
   iConfiguration          0 
   bmAttributes         0x80
     (Bus Powered)
   MaxPower              500mA
   Interface Descriptor:
     bLength                 9
     bDescriptorType         4
     bInterfaceNumber        0
     bAlternateSetting       0
     bNumEndpoints           2
     bInterfaceClass       255 Vendor Specific Class
     bInterfaceSubClass      0 
     bInterfaceProtocol      0 
     iInterface              0 
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x04  EP 4 OUT
       bmAttributes            2
         Transfer Type            Bulk
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0200  1x 512 bytes
       bInterval               0
     Endpoint Descriptor:
       bLength                 7
       bDescriptorType         5
       bEndpointAddress     0x88  EP 8 IN
       bmAttributes            2
         Transfer Type            Bulk
         Synch Type               None
         Usage Type               Data
       wMaxPacketSize     0x0200  1x 512 bytes
       bInterval               0
Device Qualifier (for other device speed):
 bLength                10
 bDescriptorType         6
 bcdUSB               2.00
 bDeviceClass            0 (Defined at Interface level)
 bDeviceSubClass         0 
 bDeviceProtocol         0 
 bMaxPacketSize0        64
 bNumConfigurations      1
Device Status:     0x0000
 (Bus Powered)