The Agilent U123xA are a series of low-cost 6000-count handheld digital multimeters. PC connectivity is via an IR port.
Hardware
- Renesas 78K0/LF3 8-bit microcontroller with 60K flash and 2K RAM on board.
Photos
Multimeter:
IR-USB cable:
See Multimeter cables#Agilent_U1173A.
IR-bluetooth interface:
See Multimeter cables#Agilent_U1177A.
Protocol
STAT
The STAT? command is used to query the current state of the device. The response is a quoted 21-byte string, like this:
"000000000110L00000000"
Byte | Value | Meaning |
---|---|---|
1 | Max/min mode | |
0 | Off | |
1 | On | |
2 | Relative measurement. The last value returned from FETC? before this mode was enabled denotes the stored reference value. | |
0 | Off | |
1 | On | |
3 | Trig hold-log | |
0 | Off | |
1 | On | |
4 | Auto hold-log | |
0 | Off | |
1 | On | |
5 | LED flashlight | |
0 | Off | |
1 | On | |
6 | LCD backlight | |
0 | Off | |
1 | On | |
7 | ||
0 | Off | |
1 | On | |
8 | Temp/aux mode. When on and rotary switch is in position 5 (capacitance), CONF? returns MV,1,DC , but the value returned from FETC? instead denotes the temperature, in the unit (F or C) according to the meter's configuration.
| |
0 | Off | |
1 | On | |
9 | ||
0 | Off | |
1 | On | |
10 | Unknown (always 1) | |
11 | Auto power-off (APO) | |
0 | Off | |
1 | On | |
12 | Unknown (always 0) | |
13 | Unknown (always L) | |
14 | Unknown (always 0) | |
15 | Unknown (always 0) | |
16 | Rotary switch position | |
0 | V/Zlow | |
1 | Voltage AC | |
2 | Voltage DC | |
3 | Resistance | |
4 | Diode | |
5 | Capacitance | |
6 | Current | |
7 | Microcurrent | |
17 | Continuity mode. When enabled, the value returned from FETC? is either NAN (no continuity) or any real value to denote continuity. | |
0 | Off | |
1 | On | |
18 | ||
0 | Off | |
1 | On | |
19 | ||
0 | Off | |
1 | On | |
20 | ||
0 | Off | |
1 | On | |
21 | ||
0 | Off | |
1 | On |