Difference between revisions of "MASTECH MAS345"
Jump to navigation
Jump to search
Uwe Hermann (talk | contribs) m |
Uwe Hermann (talk | contribs) m |
||
Line 1: | Line 1: | ||
[[File:Mastech mas345 device front.jpg|thumb|right|MASTECH MAS345]] | |||
The [http://web.archive.org/web/20080305031323/http://www.p-mastech.com/products/04_dm/mas345.html MASTECH MAS345] is a 3999 counts, CAT II handheld digital multimeter with RS232 connectivity. | The [http://web.archive.org/web/20080305031323/http://www.p-mastech.com/products/04_dm/mas345.html MASTECH MAS345] is a 3999 counts, CAT II handheld digital multimeter with RS232 connectivity. | ||
Line 24: | Line 26: | ||
== Photos == | == Photos == | ||
<gallery> | |||
File:Mastech mas345 package1.jpg | |||
File:Mastech mas345 package2.jpg | |||
File:Mastech mas345 package3.jpg | |||
File:Mastech mas345 package contents.jpg | |||
File:Mastech mas345 device front rubber.jpg | |||
File:Mastech mas345 device front.jpg | |||
File:Mastech mas345 device back.jpg | |||
File:Mastech_mas345_probes.jpg | |||
File:Mastech mas345 temperature sensor.jpg | |||
File:Mastech mas345 rs232 cable.jpg | |||
File:Mastech mas345 rs232 cable connected.jpg | |||
File:Mastech mas345 lcd1.jpg | |||
File:Mastech mas345 lcd2.jpg | |||
File:Mastech mas345 device open.jpg | |||
File:Mastech mas345 device plastic.jpg | |||
File:Mastech mas345 pcb front1.jpg | |||
File:Mastech mas345 pcb front displayremoved.jpg | |||
File:Mastech mas345 pcb front2.jpg | |||
File:Mastech mas345 pcb front3.jpg | |||
File:Mastech mas345 pcb front4.jpg | |||
File:Mastech mas345 pcb bottom1.jpg | |||
File:Mastech mas345 pcb bottom2.jpg | |||
File:Mastech mas345 display1.jpg | |||
File:Mastech mas345 display2.jpg | |||
File:Mastech mas345 pcb rs232 connector.jpg | |||
File:Mastech mas345 mastech m343-01.jpg | |||
File:Mastech mas345 gc7555ap.jpg | |||
File:Mastech mas345 sharp pc817.jpg | |||
File:Mastech mas345 st 74hc4060.jpg | |||
File:Mastech mas345 texas instruments 12al9jm.jpg | |||
</gallery> | |||
== Protocol == | == Protocol == |
Revision as of 23:39, 7 July 2012
The MASTECH MAS345 is a 3999 counts, CAT II handheld digital multimeter with RS232 connectivity.
It is also sold under the names Velleman DVM345DI, McVoice M-345pro, and Sinometer MAS345.
See MASTECH MAS345/Info for more details about the device.
Hardware
Multimeter:
- Main chip: MASTECH Japan M343-01 F0951D174 (80 pins, 16 + 16 + 24 + 24)
- 14-stage binary counter/oscillator: ST 74HC4060 N00U732
- ?: Texas Instruments 12AL9JM 0P07CP
- ?: GC7555AP AA7057HS
- ?: Sharp B B5 PC817
- ?: Sharp B B6 PC817
- Crystal: ca. 32kHz
- Fuse: 15A/250V (6x30mm) (for the 10A jack; interestingly the PCB silkscreen says "20A" for that jack)
RS232 cable:
- TODO.
Photos
Protocol
The protocol is (partially) documented in the vendor software's "Help" window (seems to apply to MAS343, MAS344, and MAS345; the M9803R protocol is different).
- Serial port settings: 600 baud, 7n2, DTR on
- Every time the host sends a (any?) character to the DMM (the vendor software sends D/0x44), it returns 14 ASCII bytes containing the measurement value and so on. The documentation states that a request interval of >= 1 second is "required for stable measuring data from meter".
Packet format:
Byte(s) | Description |
---|---|
1-2 | Measuring mode (DC, AC, OH, CA, TE, DI, ...) |
3 | Always a space (?) |
4 | Sign ('-' or ' ', i.e. a minus or a space) |
5-9 | Decimal point and current measurement value (Examples: 10.00, 0L, 3.999) |
10-13 | Unit (Examples: V, mV, A, mA, kOhm, MOhm, nF, ...) |
14 | Carriage return (13/0x0d) |
Example packets:
01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
D | C | - | 0 | 0 | 0 | . | 0 | V | \r | ||||
A | C | 0 | 0 | . | 0 | 0 | A | \r | |||||
C | A | 0 | . | 0 | 7 | 1 | n | F | \r | ||||
O | H | O | . | L | M | O | h | m | \r |
Resources
- Original English vendor manual (2008)
- elv.de: Download zu: Digital-Multimeter MAS-345 (68-04 59 88):
- German manual from ELV (2002)
- "DMM VIEW" software, version 2.0 (for Win98/NT/ME/2000/XP; supports MAS343, MAS344, MAS345, M9803R)
- cczwei-forum.de: C# software for reading DMM values