Line 26: | Line 26: | ||
* '''8-bit microcontroller with full-speed USB''': [http://www.microchip.com/wwwproducts/Devices.aspx?dDocName=en533924 Microchip PIC18F14K50] ([http://ww1.microchip.com/downloads/en/DeviceDoc/41350E.pdf datasheet]) | * '''8-bit microcontroller with full-speed USB''': [http://www.microchip.com/wwwproducts/Devices.aspx?dDocName=en533924 Microchip PIC18F14K50] ([http://ww1.microchip.com/downloads/en/DeviceDoc/41350E.pdf datasheet]) | ||
* '''Single-pole normally-closed SOP OptoMOS relay''': [http://www.ixysic.com/Products/SSRFormB.htm Ixys CPC1125N] ([http://www.ixysic.com/home/pdfs.nsf/www/CPC1125N.pdf/$file/CPC1125N.pdf datasheet]) | * '''Single-pole normally-closed SOP OptoMOS relay''': [http://www.ixysic.com/Products/SSRFormB.htm Ixys CPC1125N] ([http://www.ixysic.com/home/pdfs.nsf/www/CPC1125N.pdf/$file/CPC1125N.pdf datasheet]) | ||
* '''250MHz, rail-to-rail I/O, CMOS dual opamp''': [http://www.ti.com/product/opa2354 Texas Instruments OPA2354] ([http://www.ti.com/lit/gpn/opa2354 datasheet]) | |||
* '''Quad buffer/line driver with 5V tolerant input/outputs, 3-state''': 74LVC126A | * '''Quad buffer/line driver with 5V tolerant input/outputs, 3-state''': 74LVC126A | ||
Line 47: | Line 48: | ||
File:Lab nation smartscope maxim max19506.jpg|<small>Maxim MAX19506</small> | File:Lab nation smartscope maxim max19506.jpg|<small>Maxim MAX19506</small> | ||
File:Lab nation smartscope microchip pic 18lf14k50-i-ss.jpg|<small>Microchip 18LF14K50</small> | File:Lab nation smartscope microchip pic 18lf14k50-i-ss.jpg|<small>Microchip 18LF14K50</small> | ||
File:Lab nation smartscope cpc1125n.jpg|<small>CPC1125N</small> | File:Lab nation smartscope cpc1125n.jpg|<small>Ixys CPC1125N</small> | ||
File:Lab nation smartscope 74lvc126a.jpg|<small>74LVC126A</small> | File:Lab nation smartscope 74lvc126a.jpg|<small>74LVC126A</small> | ||
File:Lab nation smartscope oaci 45rc.jpg|<small> | File:Lab nation smartscope oaci 45rc.jpg|<small>TI OPA2354</small> | ||
</gallery> | </gallery> | ||
Revision as of 12:09, 4 December 2014
Status | planned |
---|---|
Channels | 8 |
Samplerate | 100MHz |
Samplerate (state) | — |
Triggers | low, high, rising, falling, edge |
Min/max voltage | ? |
Threshold voltage | Fixed: VIL=0.8V, VIH=2.0V |
Memory | 4Msamples (8MByte SDRAM) |
Compression | ? |
Website | lab-nation.com |
The LabNation SmartScope is a USB-based mixed-signal oscilloscope (100 MS/s, 45MHz bandwidth), 8-channel logic analyzer (100MHz), arbitrary waveform generator / function generator.
See LabNation SmartScope/Info for some more details (such as lsusb -v output) on the device.
Hardware
- FPGA (3840 logic cells): Xilinx XC6SXL4 (datasheet)
- 64Mbit SDRAM: Alliance Memory AS4C4M16S (datasheet)
- Dual-channel, 8-bit, 100Msps ADC: Maxim MAX19506 (datasheet)
- 8-bit microcontroller with full-speed USB: Microchip PIC18F14K50 (datasheet)
- Single-pole normally-closed SOP OptoMOS relay: Ixys CPC1125N (datasheet)
- 250MHz, rail-to-rail I/O, CMOS dual opamp: Texas Instruments OPA2354 (datasheet)
- Quad buffer/line driver with 5V tolerant input/outputs, 3-state: 74LVC126A