Difference between revisions of "MASTECH MAS345"
Uwe Hermann (talk | contribs) (More info and datasheets.) |
(details on the driver to use, which is probably helpful to the user) |
||
(11 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
[[File: | {{Infobox multimeter | ||
| image = [[File:Mastech_mas345_device_front.png|180px]] | |||
| name = MASTECH MAS345 | |||
| status = supported | |||
| source_code_dir = serial-dmm | |||
| counts = 4000 | |||
| categories = CAT II | |||
| connectivity = [[Device_cables#Metex_5-pin_RS232_cable|RS232]] | |||
| measurements = voltage, current, resistance, capacitance, temperature, hFE, diode, continuity | |||
| features = autorange, data hold, bargraph, backlight | |||
| website = [http://web.archive.org/web/20080305031323/http://www.p-mastech.com/products/04_dm/mas345.html p-mastech.com] | |||
}} | |||
The | The '''MASTECH MAS345''' is a 4000 counts, CAT II handheld digital multimeter with RS232 connectivity. | ||
It is also sold under the names [http://www.circuitspecialists.com/csi345.html Circuit Specialists CSI345]<sup>1</sup>, [http://web.archive.org/web/20070224223043/http://www.globalspecialties.com/pro70.html Global Specialties Pro-70], [http://www.xlsmess.de/html/mcvoice_-_m-345pro.html McVoice M-345pro], [http://www.sinometer.com/jpg/MAS345.jpg Sinometer MAS345]. and [http://www.velleman.eu/products/view/?country=ot&lang=de&id=341708 Velleman DVM345DI]. | It is also sold under the names [http://www.circuitspecialists.com/csi345.html Circuit Specialists CSI345]<sup>1</sup>, [http://web.archive.org/web/20070224223043/http://www.globalspecialties.com/pro70.html Global Specialties Pro-70], [http://www.xlsmess.de/html/mcvoice_-_m-345pro.html McVoice M-345pro], [http://www.sinometer.com/jpg/MAS345.jpg Sinometer MAS345]. and [http://www.velleman.eu/products/view/?country=ot&lang=de&id=341708 Velleman DVM345DI]. | ||
Line 27: | Line 38: | ||
'''RS232 cable''': | '''RS232 cable''': | ||
* See [[ | * See [[Device_cables#Metex_5-pin_RS232_cable]]. | ||
== Driver == | |||
Uses the driver '''mastech-mas345'''. You'll generally need the 'conn' driver option to specify the serial device to use. | |||
Example: | |||
sigrok-cli --driver mastech-mas345:conn=/dev/ttyUSB0 --samples 10 | |||
== Photos == | == Photos == | ||
Line 34: | Line 53: | ||
<gallery> | <gallery> | ||
File:Mastech mas345 package1.jpg | File:Mastech mas345 package1.jpg|<small>Outer package</small> | ||
File:Mastech mas345 package2.jpg | File:Mastech mas345 package2.jpg|<small>Package</small> | ||
File:Mastech mas345 package3.jpg | File:Mastech mas345 package3.jpg|<small>Package, open</small> | ||
File:Mastech mas345 package contents.jpg | File:Mastech mas345 package contents.jpg|<small>Package contents</small> | ||
File:Mastech mas345 device front rubber.jpg | File:Mastech mas345 device front rubber.jpg|<small>Device, rubber holster</small> | ||
File:Mastech mas345 device front.jpg | File:Mastech mas345 device front.jpg|<small>Device, front</small> | ||
File:Mastech mas345 device back.jpg | File:Mastech mas345 device back.jpg|<small>Device, back</small> | ||
File:Mastech_mas345_probes.jpg | File:Mastech_mas345_probes.jpg|<small>Probes</small> | ||
File:Mastech mas345 temperature sensor.jpg | File:Mastech mas345 temperature sensor.jpg|<small>Temperature probe</small> | ||
File:Mastech mas345 lcd1.jpg | File:Mastech mas345 lcd1.jpg|<small>LCD</small> | ||
File:Mastech mas345 lcd2.jpg | File:Mastech mas345 lcd2.jpg|<small>LCD w/ backlight</small> | ||
File:Mastech mas345 device open.jpg | File:Mastech mas345 device open.jpg|<small>Device, open</small> | ||
File:Mastech mas345 device plastic.jpg | File:Mastech mas345 device plastic.jpg|<small>Front cover</small> | ||
File:Mastech mas345 pcb front1.jpg | File:Mastech mas345 pcb front1.jpg|<small>PCB, front</small> | ||
File:Mastech mas345 pcb front displayremoved.jpg | File:Mastech mas345 pcb front displayremoved.jpg|<small>PCB, front, w/o LCD</small> | ||
File:Mastech mas345 pcb front2.jpg | File:Mastech mas345 pcb front2.jpg|<small>PCB, front top</small> | ||
File:Mastech mas345 pcb front3.jpg | File:Mastech mas345 pcb front3.jpg|<small>PCB, front middle</small> | ||
File:Mastech mas345 pcb front4.jpg | File:Mastech mas345 pcb front4.jpg|<small>PCB, front bottom</small> | ||
File:Mastech mas345 pcb bottom1.jpg | File:Mastech mas345 pcb bottom1.jpg|<small>PCB, back 1</small> | ||
File:Mastech mas345 pcb bottom2.jpg | File:Mastech mas345 pcb bottom2.jpg|<small>PCB, back 2</small> | ||
File:Mastech mas345 display1.jpg | File:Mastech mas345 display1.jpg|<small>LCD 1</small> | ||
File:Mastech mas345 display2.jpg | File:Mastech mas345 display2.jpg|<small>LCD 2</small> | ||
File:Mastech mas345 pcb rs232 connector.jpg | File:Mastech mas345 pcb rs232 connector.jpg|<small>RS232 connector</small> | ||
File:Mastech mas345 mastech m343-01.jpg | File:Mastech mas345 mastech m343-01.jpg|<small>MASTECH M343-01</small> | ||
File:Mastech mas345 gc7555ap.jpg | File:Mastech mas345 gc7555ap.jpg|<small>GC7555AP</small> | ||
File:Mastech mas345 sharp pc817.jpg | File:Mastech mas345 sharp pc817.jpg|<small>Sharp PC817</small> | ||
File:Mastech mas345 st 74hc4060.jpg | File:Mastech mas345 st 74hc4060.jpg|<small>ST 74HC4060</small> | ||
File:Mastech mas345 texas instruments 12al9jm.jpg | File:Mastech mas345 texas instruments 12al9jm.jpg|<small>TI OP07C</small> | ||
</gallery> | </gallery> | ||
'''RS232 cable''': | '''RS232 cable''': | ||
See [[ | See [[Device_cables#Metex_5-pin_RS232_cable]]. | ||
== Protocol == | == Protocol == | ||
Line 72: | Line 91: | ||
The protocol is (partially) documented in the vendor software's "Help" window (seems to apply to MAS343, MAS344, and MAS345; the M9803R protocol is different). | The protocol is (partially) documented in the vendor software's "Help" window (seems to apply to MAS343, MAS344, and MAS345; the M9803R protocol is different). | ||
See [[Multimeter_ICs#Metex_14-byte_ASCII]] for the DMM IC protocol. | |||
== Resources == | == Resources == | ||
Line 206: | Line 106: | ||
* [http://www.b-redemann.de/sp-DMM-auslesen.shtml b-redemann.de Auslesen von Messgeräten mit RS232 Interface über USB] | * [http://www.b-redemann.de/sp-DMM-auslesen.shtml b-redemann.de Auslesen von Messgeräten mit RS232 Interface über USB] | ||
* [http://freecode.com/projects/tmon tmon] (uses a MASTECH MAS345) | * [http://freecode.com/projects/tmon tmon] (uses a MASTECH MAS345) | ||
[[Category:Device]] | |||
[[Category:Multimeter]] | |||
[[Category:Supported]] |
Latest revision as of 06:36, 20 January 2016
Status | supported |
---|---|
Source code | serial-dmm |
Counts | 4000 |
IEC 61010-1 | CAT II |
Connectivity | RS232 |
Measurements | voltage, current, resistance, capacitance, temperature, hFE, diode, continuity |
Features | autorange, data hold, bargraph, backlight |
Website | p-mastech.com |
The MASTECH MAS345 is a 4000 counts, CAT II handheld digital multimeter with RS232 connectivity.
It is also sold under the names Circuit Specialists CSI3451, Global Specialties Pro-70, McVoice M-345pro, Sinometer MAS345. and Velleman DVM345DI.
1 The software shipped by Circuit Specialists is MasView 1.1.
Hardware
Multimeter:
- Main chip: MASTECH Japan M343-01 F0951D174 (80 pins, 16 + 16 + 24 + 24)
- 14-stage binary counter/oscillator: ST 74HC4060 (datasheet) (marking: "ST 74HC4060 N00U732")
- Precision perational amplifier: Texas Instruments OP07C (datasheet) (marking: "12AL9JM 0P07CP")
- CMOS multifunctional time base circuit: Green Sea Technology GC7555AP (datasheet, English translation) (marking: "GC7555AP AA7057HS")
- This is an NE555 compatible chip, apparently.
- General-purpose photocoupler: Sharp PC817 (datasheet) (marking: "B > B5 PC817 Sharp")
- "B": model = PC817X2J000F/PC817XF2J00F, ">": China factory, "B5": date code == May 1991
- General-purpose photocoupler: Sharp PC817 (datasheet) (marking: "B > B6 PC817 Sharp")
- "B": model = PC817X2J000F/PC817XF2J00F, ">": China factory, "B6": date code == June 1991
- Crystal: ca. 32kHz
- Fuse: 15A/250V (6x30mm) (for the 10A jack; interestingly the PCB silkscreen says "20A" for that jack)
RS232 cable:
Driver
Uses the driver mastech-mas345. You'll generally need the 'conn' driver option to specify the serial device to use.
Example:
sigrok-cli --driver mastech-mas345:conn=/dev/ttyUSB0 --samples 10
Photos
Multimeter:
RS232 cable:
See Device_cables#Metex_5-pin_RS232_cable.
Protocol
The protocol is (partially) documented in the vendor software's "Help" window (seems to apply to MAS343, MAS344, and MAS345; the M9803R protocol is different).
See Multimeter_ICs#Metex_14-byte_ASCII for the DMM IC protocol.
Resources
- Original English vendor manual (2008)
- elv.de: Download zu: Digital-Multimeter MAS-345 (68-04 59 88):
- German manual from ELV (2002)
- "DMM VIEW" software, version 2.0 (for Win98/NT/ME/2000/XP; supports MAS343, MAS344, MAS345, M9803R)
- cczwei-forum.de: C# software for reading DMM values
- Linux Magazin: E-Werke: Perl misst Stromverbrauch mit Multimeter
- mas-345/marsh: multimeter read and store
- digitaltrip.hu: Mastech MAS-345 digital multimeter Windows GUI (github)
- github: device-mas345-perl
- b-redemann.de Auslesen von Messgeräten mit RS232 Interface über USB
- tmon (uses a MASTECH MAS345)