Difference between revisions of "Manson HCS-3xxx series"
Uwe Hermann (talk | contribs) m (→Resources) |
Uwe Hermann (talk | contribs) m |
||
Line 19: | Line 19: | ||
{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable" | {| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable" | ||
|- | |- | ||
!Manson | !Manson | ||
!Conrad OEM | !Conrad OEM | ||
!Peaktech OEM | !Peaktech OEM | ||
!Voltage | !Voltage range | ||
!Current | !Current range | ||
!Power | !Power | ||
! | !Comments | ||
|- | |- | ||
Line 175: | Line 174: | ||
|} | |} | ||
The voltage and current specs are rounded values from the manufacturer's specs. The devices might allow slightly higher values for voltage and current. The exact values read from the devices are available by listing the config keys SR_CONF_OUTPUT_VOLTAGE_MAX and | The voltage and current specs are rounded values from the manufacturer's specs. The devices might allow slightly higher values for voltage and current. The exact values read from the devices are available by listing the config keys '''SR_CONF_OUTPUT_VOLTAGE_MAX''' and '''SR_CONF_OUTPUT_CURRENT_MAX'''. | ||
The devices linked above are supported. The other devices might work, but are untested. If you have one of the unsupported devices and can test it, please contact | The devices linked above are supported. The other devices might work, but are untested. If you have one of the unsupported devices and can test it, please contact [[User:Matthias_Heidbrink|Matthias]]. | ||
Some other device series by the same manufacturer exist that use a different communication protocol. | Some other device series by the same manufacturer exist that use a different communication protocol. | ||
Line 188: | Line 187: | ||
! Target | ! Target | ||
! Parameters | ! Parameters | ||
! | ! Comments | ||
|- | |- | ||
Line 206: | Line 205: | ||
| Device | | Device | ||
| Double | | Double | ||
| List: Get 3-tuple (min, max, step) for output voltage range. Get: Get output voltage limit. Set: Set output voltage limit. | |||
|- | |- | ||
Line 218: | Line 217: | ||
| Device | | Device | ||
| Double | | Double | ||
| List: Get 3- | | List: Get 3-tuple (min, max, step) for output current range. Get: Get output current limit. Set: Set output current limit. | ||
|} | |} | ||
Line 225: | Line 224: | ||
== Protocol == | == Protocol == | ||
Some versions of the protocol description in manuals are incomplete or even erroneous. | The devices uses an ASCII-based protocol over a USB-to-serial link. | ||
All commands and replies end with a newline ('''\n''') character. | |||
Some versions of the protocol description in manuals are incomplete or even erroneous. | |||
{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable" | {| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable" | ||
|- | |- | ||
!Command | !Command | ||
!Reply | !Reply | ||
!Description | !Description | ||
! | !Comments | ||
|- | |- | ||
Line 241: | Line 242: | ||
| 3204\r<br/>OK\r | | 3204\r<br/>OK\r | ||
| Query model | | Query model | ||
| Four-digit model code, e.g. | | Four-digit model code, e.g. ''3202'' for the [[Manson HCS-3202|HCS-3202]]. | ||
|- | |- | ||
Line 250: | Line 251: | ||
|- | |- | ||
| SOUT | | SOUT''n''\r | ||
| OK\r | | OK\r | ||
| Disable output | | Disable output | ||
Line 268: | Line 269: | ||
|- | |- | ||
| VOLT | | VOLT''nnn''\r | ||
| OK\r | | OK\r | ||
| Set voltage to nn.n. | | Set voltage to nn.n. | ||
Line 274: | Line 275: | ||
|- | |- | ||
| CURR | | CURR''nnn''\r | ||
| OK\r | | OK\r | ||
| Set current to nn.n or n.nn (model- | | Set current to nn.n or n.nn (model-dependent!). | ||
| | | | ||
Revision as of 21:44, 1 September 2014
Status | supported |
---|---|
Source code | manson-hcs-3xxx |
Channels | 1 |
Voltage/current (CH1) | various |
Connectivity | USB |
Features | programmable presets, cycling functionality |
Website | manson.com.hk |
The Manson HCS-3xxx series are 1 channel switch-mode programmable power supplies with USB/serial connectivity.
Devices
Manson | Conrad OEM | Peaktech OEM | Voltage range | Current range | Power | Comments |
---|---|---|---|---|---|---|
HCS-3100 | PPS-11810 | 1-18 V | 0-10 A | 180 W | ||
HCS-3102 | PPS-11360 | 1-36 V | 0-5 A | 180 W | ||
HCS-3104 | PPS-11603 | 1-60 V | 0-2.5 A | 150 W | ||
HCS-3150 | - | 1-18 V | 0-15 A | 270 W | ||
HCS-3200 | PPS-13610 | 1-18 V | 0-20 A | 360 W | ||
HCS-3202 | PPS-16005 | 1-36 V | 0-10 A | 360 W | ||
HCS-3204 | PPS-11815 | 1-60 V | 0-5 A | 300 W | ||
HCS-3300-USB | - | - | 1-16 V | 0-30 A | 480 W | |
HCS-3302-USB | - | - | 1-32 V | 0-15 A | 480 W | |
HCS-3304-USB | - | - | 1-60 V | 0-8 A | 480 W | |
HCS-3400-USB | - | PeakTech 1565 | 1-16 V | 0-40 A | 600 W | |
HCS-3402-USB | - | PeakTech 1575 | 1-32 V | 0-20 A | 600 W? | |
HCS-3404-USB | - | - | 1-60 V | 0-10 A | 600 W | |
HCS-3600-USB | - | PeakTech 1580 | 1-16 V | 0-60 A | 750 W | |
HCS-3602-USB | - | PeakTech 1580 | 1-30 V | 0-30 A | 900 W | |
HCS-3604-USB | - | - | 1-60 V | 0-15 A | 900 W |
The voltage and current specs are rounded values from the manufacturer's specs. The devices might allow slightly higher values for voltage and current. The exact values read from the devices are available by listing the config keys SR_CONF_OUTPUT_VOLTAGE_MAX and SR_CONF_OUTPUT_CURRENT_MAX.
The devices linked above are supported. The other devices might work, but are untested. If you have one of the unsupported devices and can test it, please contact Matthias.
Some other device series by the same manufacturer exist that use a different communication protocol.
Config keys
Function | Target | Parameters | Comments |
---|---|---|---|
SR_CONF_OUTPUT_ENABLED | Device | Boolean on/off | Get: Query output status. Set: Switch output on or off. Power-on default is on. |
SR_CONF_OUTPUT_VOLTAGE | Device | Double | Get: Query output voltage. Updated only if sampling is active! |
SR_CONF_OUTPUT_VOLTAGE_MAX | Device | Double | List: Get 3-tuple (min, max, step) for output voltage range. Get: Get output voltage limit. Set: Set output voltage limit. |
SR_CONF_OUTPUT_CURRENT | Device | Double | Get: Query output current. Updated only if sampling is active! |
SR_CONF_OUTPUT_CURRENT_MAX | Device | Double | List: Get 3-tuple (min, max, step) for output current range. Get: Get output current limit. Set: Set output current limit. |
See also Programmable power supply!
Protocol
The devices uses an ASCII-based protocol over a USB-to-serial link.
All commands and replies end with a newline (\n) character.
Some versions of the protocol description in manuals are incomplete or even erroneous.
Command | Reply | Description | Comments |
---|---|---|---|
GMOD\r | 3204\r OK\r |
Query model | Four-digit model code, e.g. 3202 for the HCS-3202. |
GETD\r | VVVVCCCCS\r OK\r |
Query displayed voltage, current and mode. | Four-digit voltage, e.g. 12.34; four-digit current, e.g. 12.34; status 0=constant voltage, 1=constant current. |
SOUTn\r | OK\r | Disable output | Output on=0 (power-on default), off=1 |
SESS\r | OK\r | Disable keyboard | Seems to time out after about 5 seconds. |
ENDS\r | OK\r | Enable keyboard | When disabled with SESS. |
VOLTnnn\r | OK\r | Set voltage to nn.n. | |
CURRnnn\r | OK\r | Set current to nn.n or n.nn (model-dependent!). | |
... | ... | ... | Protocol description incomplete so far. |
Resources
- Vendor control software (HCS_PC_software_v0_9.rar)
- Vendor Labview driver (HCS_labview_high_current_v0_1.rar)
- reinhardweiss.de: Manson HCS-3204 info (most of it also applies to the other devices in the series)
- goughlui.com: Review: Manson HCS-3102 1-36v/0-5A Switch-Mode Benchtop Power Supply (most of it also applies to the other devices in the series)
- ELV: HCS-3200/3202/3204 manual (contains some more commands than the manufacturer's docs)