Difference between revisions of "Sigrok-cli"
Jump to navigation
Jump to search
Uwe Hermann (talk | contribs) m |
Uwe Hermann (talk | contribs) m (→manpage: Update manpage, by copy-pasting "nroff -man sigrok-cli.1" output from the console.) |
||
| Line 4: | Line 4: | ||
<pre> | <pre> | ||
SIGROK-CLI(1) SIGROK-CLI(1) | |||
NAME | NAME | ||
sigrok-cli - Command-line client for the sigrok logic analyzer software | sigrok-cli - Command-line client for the sigrok logic analyzer software | ||
SYNOPSIS | SYNOPSIS | ||
sigrok-cli [- | sigrok-cli [-hVlDdiIoOptwas] [-h|--help] [-V|--version] [-l|--loglevel | ||
level] [-D|--list-devices] [-d|--device device] [-i|--input-file file‐ | |||
[- | name] [-I|--input-format format] [-o|--output-file filename] [-O|--out‐ | ||
put-format format] [-p|--probes probelist] [-t|--triggers triggerlist] | |||
[-w|--wait-trigger] [-a|--protocol-decoders list] [-s|--proto‐ | |||
col-decoder-stack stack] [--time ms] [--samples numsamples] [--continu‐ | |||
ous] | |||
DESCRIPTION | DESCRIPTION | ||
| Line 20: | Line 26: | ||
The command-line frontend for sigrok cannot display graphical output, | The command-line frontend for sigrok cannot display graphical output, | ||
but is still sufficient to run through the whole process of hardware | but is still sufficient to run through the whole process of hardware | ||
initialization, acquisition, protocol | initialization, acquisition, protocol decoding and saving the session. | ||
It is useful for running on remote or embedded systems, netbooks, PDAs, | It is useful for running on remote or embedded systems, netbooks, PDAs, | ||
| Line 27: | Line 33: | ||
OPTIONS | OPTIONS | ||
-h, --help | |||
Show a help text and exit. | |||
-V, --version | -V, --version | ||
Show version, | Show sigrok-cli version, and information about supported hard‐ | ||
ware drivers, input file formats, output file formats, and pro‐ | |||
tocol decoders. | |||
-l, --loglevel <level> | |||
Set the libsigrok and libsigrokdecode loglevel. At the moment | |||
sigrok-cli doesn't support setting the two loglevels indepen‐ | |||
dently. The higher the number, the more debug output will be | |||
printed. Valid loglevels are 0 (NONE), 1 (ERR), 2 (WARN), 3 | |||
(INFO), 4 (DBG), and 5 (SPEW). | |||
-D, --list-devices | -D, --list-devices | ||
List all logic analyzer devices found on the system. | List all logic analyzer devices found on the system. This | ||
actively scans for devices (USB, serial port, and others). | |||
-d, --device < | -d, --device <device> | ||
The device to use for acquisition | The device to use for acquisition. It can be specified by ID as | ||
by --list-devices. | reported by --list-devices, or by the name of the driver as | ||
reported by --version. | |||
A device can optionally be followed by a colon-separated list of | |||
device | device options, where each option takes the form key=value. For | ||
example, to set the samplerate on the first device you might | |||
specify | |||
$ sigrok-cli -d 0:samplerate=1m | |||
The | Samplerate is an option common to most devices. The argument | ||
specifies the samplerate in Hz. You can also specify the sam‐ | |||
plerate in kHz, MHz or GHz. The following are all equivalent: | |||
$ sigrok-cli --samples 100 -d 0:samplerate=1000000 | |||
$ sigrok-cli --samples 100 -d 0:samplerate=1m | |||
$ sigrok-cli --samples 100 -d "0:samplerate=1 MHz" | |||
-i, --input-file <filename> | |||
Load input from a file instead of a hardware device. If the | |||
--input-format option is not supplied, sigrok-cli attempts to | |||
autodetect the file format of the input file. | |||
-I, --input-format <format> | |||
When loading an input file, assume it's in the specified format. | |||
If this option is not supplied (in addition to --input-file), | |||
sigrok-cli attempts to autodetect the file format of the input | |||
file. | |||
-o, --output-file <filename> | |||
Save output to a file instead of writing it to stdout. The | |||
default format used when saving is the sigrok session file for‐ | |||
mat. This can be changed with the --output-format option. | |||
-O, --output-format <formatname> | |||
Set the output format to use. Use the -V option to see a list of | |||
available output formats. The format name may optionally be fol‐ | |||
lowed by a colon-separated list of options, where each option | |||
takes the form key=value. | |||
Supported formats currently include bits, hex, ascii, binary, | |||
vcd, ols, gnuplot, chronovu-la8, and csv. | |||
The bits or hex formats, for an ASCII bit or ASCII hexadecimal | |||
display, can take a "width" option, specifying the number of | |||
samples (in bits) to display per line. Thus hex:width=128 will | |||
display 128 bits per line, in hexadecimal: | |||
1:ffff ffff ffff ffff ffff ffff ffff ffff | |||
2:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00 | |||
The lines always start with the probe number (or name, if | |||
defined), followed by a colon. If no format is specified, it | |||
defaults to bits:width=64, like this: | |||
1:11111111 11111111 11111111 11111111 [...] | |||
2:11111111 00000000 11111111 00000000 [...] | |||
-p, --probes <probelist> | -p, --probes <probelist> | ||
A comma-separated list of probes to be used in the session. | A comma-separated list of probes to be used in the session. | ||
The | The default is to use all the probes available on a device. You | ||
can name a probe like this: 1=CLK. A range of probes | can name a probe like this: 1=CLK. A range of probes can also | ||
be given, in the form 1-5. | be given, in the form 1-5. | ||
| Line 66: | Line 130: | ||
7:11111111 11111111 11111111 11111111 [...] | 7:11111111 11111111 11111111 11111111 [...] | ||
The | The comma-separated list is processed from left to right, i.e. | ||
items farther to the right override previous items. For | items farther to the right override previous items. For example | ||
1=CS,1=MISO will set the name of probe 1 to MISO. | 1=CS,1=MISO will set the name of probe 1 to MISO. | ||
Also, | Also, while 5=MOSI,6=MISO will only select probes 5 and 6, and | ||
set | set their names to MISO and MOSI, the command line | ||
5=MOSI,6=MISO,1-8 | 5=MOSI,6=MISO,1-8 will select probes 1-8 (including 5 and 6, of | ||
course), but the names specified for probes | course), but the names specified for probes 5 and 6 will be | ||
reset to the defaults by the 1-8 probe selection. | reset to the defaults by the 1-8 probe selection. | ||
-t, --triggers <triggerlist> | -t, --triggers <triggerlist> | ||
A | A comma-separated list of triggers to use, of the form | ||
<probe>=<trigger>. You can use the name or number of the probe, | <probe>=<trigger>. You can use the name or number of the probe, | ||
and the trigger itself is a series of characters: | and the trigger itself is a series of characters: | ||
0 or 1: A low or high value on the pin. | 0 or 1: A low or high value on the pin. | ||
r | r or f: A rising or falling value on the pin. An r effectively | ||
corresponds to 01. | corresponds to 01. | ||
c: Any kind of change on a pin. | c: Any kind of change on a pin (either a rising or a falling | ||
edge). | |||
Not every device supports all of these trigger types. Use the -d | Not every device supports all of these trigger types. Use the -d | ||
<device | <device> argument (with no other arguments) to see which trig‐ | ||
gers your device supports. | |||
- | -w, --wait-trigger | ||
Don't output any sample data (even if it's actually received | |||
from the logic analyzer) before the trigger condition is met. In | |||
other words, do not output any pre-trigger data. This option is | |||
useful if you don't care about the data that came before the | |||
trigger (but the logic analyzer hardware delivers this data to | |||
sigrok nonetheless). | |||
-a, --protocol-decoders <list> | |||
This option allows the user to specify a comma-separated list of | |||
protocol decoders to be used in this session. The decoders are | |||
specified by their ID, as shown in the --version output. | |||
Example: | |||
$ sigrok-cli -i <file.sr> -a i2c | |||
Each protocol decoder can optionally be followed by a colon-sep‐ | |||
arated list of options, where each option takes the form | |||
key=value. | |||
Example: | |||
$ sigrok-cli -i <file.sr> -a uart:baudrate=115200:parity=odd | |||
The list of supported options depends entirely on the protocol | |||
decoder. Every protocol decoder has different options it sup‐ | |||
ports. | |||
Any "options" specified for a protocol decoder which are not | |||
actually supported options, will be interpreted as being probe | |||
name/number assignments. | |||
Example: | |||
$ sigrok-cli -i <file.sr> | |||
-a spi:wordsize=9:miso=1:mosi=5:sck=3:cs=0 | |||
In this example, wordsize is an option supported by the spi pro‐ | |||
tocol decoder. Additionally, the user tells sigrok to decode the | |||
SPI protocol using probe 1 as MISO signal for SPI, probe 5 as | |||
MOSI, probe 3 as SCK, and probe 0 as CS# signal. | |||
- | -s, --protocol-decoder-stack <stack> | ||
This option allows the user to specify a protocol decoder stack, | |||
i.e. the way in which one protocol decoder's output gets piped | |||
into another protocol decoder. | |||
The decoders are specified by their ID, as shown in the --ver‐ | |||
sion output. In addition to the -s option, all protocol decoders | |||
that are used in a stack, must also be specified (together with | |||
their options, if any) using the -a parameter. | |||
Example: | |||
$ sigrok-cli -i <file.sr> -a i2c:sda=4,scl=7,rtc8564 | |||
-s i2c,rtc8564 | |||
In this example, the -s option specifies that the output of the | |||
i2c decoder is piped into the rtc8564 decoder, i.e., the rtc8564 | |||
decoder is stacked on top of the i2c decoder. | |||
The respective protocol decoder options and probe name/number | |||
assignments must be given using the -a option (you cannot spec‐ | |||
ify them in the -s option). | |||
--time <ms> | --time <ms> | ||
Sample for <ms> milliseconds, then quit. You can optionally fol‐ | Sample for <ms> milliseconds, then quit. You can optionally fol‐ | ||
low | low the number by s to state the number of seconds to sample | ||
instead. For example, --time 2s will sample for two seconds. | instead. For example, --time 2s will sample for two seconds. | ||
| Line 127: | Line 231: | ||
--continuous | --continuous | ||
Sample continuously until stopped. Not all devices support this. | Sample continuously until stopped. Not all devices support this. | ||
EXAMPLES | EXAMPLES | ||
| Line 145: | Line 246: | ||
sigrok-cli --time 3s | sigrok-cli --time 3s | ||
To | To capture data from 4 probes lasting 100ms at 10 MHz starting at the | ||
trigger condition 1:high, 2:rising, 3:low, 4:high, use: | trigger condition 1:high, 2:rising, 3:low, 4:high, use: | ||
sigrok-cli - | sigrok-cli -d 0:samplerate=10m -O bits -p 1-4 --time 100 \ | ||
--wait-trigger --triggers 1=1,2=r,3=0,4=1 | --wait-trigger --triggers 1=1,2=r,3=0,4=1 | ||
| Line 155: | Line 256: | ||
SEE ALSO | SEE ALSO | ||
sigrok- | sigrok-qt(1), sigrok-gtk(1) | ||
BUGS | BUGS | ||
Please report any | Please report any bugs on the sigrok-devel mailing list | ||
(sigrok-devel@lists.souceforge.net). | |||
LICENSE | LICENSE | ||
sigrok-cli | sigrok-cli is covered by the GNU General Public License (GPL). Some | ||
portions are licensed under the "GPL v2 or later", some under | portions are licensed under the "GPL v2 or later", some under "GPL v3 | ||
or later". | or later". | ||
| Line 169: | Line 270: | ||
Please see the individual source code files. | Please see the individual source code files. | ||
This | This manual page was written by Uwe Hermann <uwe@hermann-uwe.de>. It | ||
is licensed under the terms of the GNU GPL (version 2 or later). | is licensed under the terms of the GNU GPL (version 2 or later). | ||
March 18, 2012 SIGROK-CLI(1) | |||
</pre> | </pre> | ||
Revision as of 16:00, 19 April 2012
sigrok-cli is a command-line frontend for sigrok.
manpage
SIGROK-CLI(1) SIGROK-CLI(1)
NAME
sigrok-cli - Command-line client for the sigrok logic analyzer software
SYNOPSIS
sigrok-cli [-hVlDdiIoOptwas] [-h|--help] [-V|--version] [-l|--loglevel
level] [-D|--list-devices] [-d|--device device] [-i|--input-file file‐
name] [-I|--input-format format] [-o|--output-file filename] [-O|--out‐
put-format format] [-p|--probes probelist] [-t|--triggers triggerlist]
[-w|--wait-trigger] [-a|--protocol-decoders list] [-s|--proto‐
col-decoder-stack stack] [--time ms] [--samples numsamples] [--continu‐
ous]
DESCRIPTION
sigrok-cli is a cross-platform command line utility for the sigrok
logic analyzer software.
The command-line frontend for sigrok cannot display graphical output,
but is still sufficient to run through the whole process of hardware
initialization, acquisition, protocol decoding and saving the session.
It is useful for running on remote or embedded systems, netbooks, PDAs,
and for various other use-cases. It can display samples on standard
output or save them in various file formats.
OPTIONS
-h, --help
Show a help text and exit.
-V, --version
Show sigrok-cli version, and information about supported hard‐
ware drivers, input file formats, output file formats, and pro‐
tocol decoders.
-l, --loglevel <level>
Set the libsigrok and libsigrokdecode loglevel. At the moment
sigrok-cli doesn't support setting the two loglevels indepen‐
dently. The higher the number, the more debug output will be
printed. Valid loglevels are 0 (NONE), 1 (ERR), 2 (WARN), 3
(INFO), 4 (DBG), and 5 (SPEW).
-D, --list-devices
List all logic analyzer devices found on the system. This
actively scans for devices (USB, serial port, and others).
-d, --device <device>
The device to use for acquisition. It can be specified by ID as
reported by --list-devices, or by the name of the driver as
reported by --version.
A device can optionally be followed by a colon-separated list of
device options, where each option takes the form key=value. For
example, to set the samplerate on the first device you might
specify
$ sigrok-cli -d 0:samplerate=1m
Samplerate is an option common to most devices. The argument
specifies the samplerate in Hz. You can also specify the sam‐
plerate in kHz, MHz or GHz. The following are all equivalent:
$ sigrok-cli --samples 100 -d 0:samplerate=1000000
$ sigrok-cli --samples 100 -d 0:samplerate=1m
$ sigrok-cli --samples 100 -d "0:samplerate=1 MHz"
-i, --input-file <filename>
Load input from a file instead of a hardware device. If the
--input-format option is not supplied, sigrok-cli attempts to
autodetect the file format of the input file.
-I, --input-format <format>
When loading an input file, assume it's in the specified format.
If this option is not supplied (in addition to --input-file),
sigrok-cli attempts to autodetect the file format of the input
file.
-o, --output-file <filename>
Save output to a file instead of writing it to stdout. The
default format used when saving is the sigrok session file for‐
mat. This can be changed with the --output-format option.
-O, --output-format <formatname>
Set the output format to use. Use the -V option to see a list of
available output formats. The format name may optionally be fol‐
lowed by a colon-separated list of options, where each option
takes the form key=value.
Supported formats currently include bits, hex, ascii, binary,
vcd, ols, gnuplot, chronovu-la8, and csv.
The bits or hex formats, for an ASCII bit or ASCII hexadecimal
display, can take a "width" option, specifying the number of
samples (in bits) to display per line. Thus hex:width=128 will
display 128 bits per line, in hexadecimal:
1:ffff ffff ffff ffff ffff ffff ffff ffff
2:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00
The lines always start with the probe number (or name, if
defined), followed by a colon. If no format is specified, it
defaults to bits:width=64, like this:
1:11111111 11111111 11111111 11111111 [...]
2:11111111 00000000 11111111 00000000 [...]
-p, --probes <probelist>
A comma-separated list of probes to be used in the session.
The default is to use all the probes available on a device. You
can name a probe like this: 1=CLK. A range of probes can also
be given, in the form 1-5.
Example:
$ sigrok-cli --samples 100 --probes 1=CLK,2-4,7
CLK:11111111 11111111 11111111 11111111 [...]
2:11111111 11111111 11111111 11111111 [...]
3:11111111 11111111 11111111 11111111 [...]
4:11111111 11111111 11111111 11111111 [...]
7:11111111 11111111 11111111 11111111 [...]
The comma-separated list is processed from left to right, i.e.
items farther to the right override previous items. For example
1=CS,1=MISO will set the name of probe 1 to MISO.
Also, while 5=MOSI,6=MISO will only select probes 5 and 6, and
set their names to MISO and MOSI, the command line
5=MOSI,6=MISO,1-8 will select probes 1-8 (including 5 and 6, of
course), but the names specified for probes 5 and 6 will be
reset to the defaults by the 1-8 probe selection.
-t, --triggers <triggerlist>
A comma-separated list of triggers to use, of the form
<probe>=<trigger>. You can use the name or number of the probe,
and the trigger itself is a series of characters:
0 or 1: A low or high value on the pin.
r or f: A rising or falling value on the pin. An r effectively
corresponds to 01.
c: Any kind of change on a pin (either a rising or a falling
edge).
Not every device supports all of these trigger types. Use the -d
<device> argument (with no other arguments) to see which trig‐
gers your device supports.
-w, --wait-trigger
Don't output any sample data (even if it's actually received
from the logic analyzer) before the trigger condition is met. In
other words, do not output any pre-trigger data. This option is
useful if you don't care about the data that came before the
trigger (but the logic analyzer hardware delivers this data to
sigrok nonetheless).
-a, --protocol-decoders <list>
This option allows the user to specify a comma-separated list of
protocol decoders to be used in this session. The decoders are
specified by their ID, as shown in the --version output.
Example:
$ sigrok-cli -i <file.sr> -a i2c
Each protocol decoder can optionally be followed by a colon-sep‐
arated list of options, where each option takes the form
key=value.
Example:
$ sigrok-cli -i <file.sr> -a uart:baudrate=115200:parity=odd
The list of supported options depends entirely on the protocol
decoder. Every protocol decoder has different options it sup‐
ports.
Any "options" specified for a protocol decoder which are not
actually supported options, will be interpreted as being probe
name/number assignments.
Example:
$ sigrok-cli -i <file.sr>
-a spi:wordsize=9:miso=1:mosi=5:sck=3:cs=0
In this example, wordsize is an option supported by the spi pro‐
tocol decoder. Additionally, the user tells sigrok to decode the
SPI protocol using probe 1 as MISO signal for SPI, probe 5 as
MOSI, probe 3 as SCK, and probe 0 as CS# signal.
-s, --protocol-decoder-stack <stack>
This option allows the user to specify a protocol decoder stack,
i.e. the way in which one protocol decoder's output gets piped
into another protocol decoder.
The decoders are specified by their ID, as shown in the --ver‐
sion output. In addition to the -s option, all protocol decoders
that are used in a stack, must also be specified (together with
their options, if any) using the -a parameter.
Example:
$ sigrok-cli -i <file.sr> -a i2c:sda=4,scl=7,rtc8564
-s i2c,rtc8564
In this example, the -s option specifies that the output of the
i2c decoder is piped into the rtc8564 decoder, i.e., the rtc8564
decoder is stacked on top of the i2c decoder.
The respective protocol decoder options and probe name/number
assignments must be given using the -a option (you cannot spec‐
ify them in the -s option).
--time <ms>
Sample for <ms> milliseconds, then quit. You can optionally fol‐
low the number by s to state the number of seconds to sample
instead. For example, --time 2s will sample for two seconds.
--samples <numsamples>
Acquire <numsamples> samples, then quit.
--continuous
Sample continuously until stopped. Not all devices support this.
EXAMPLES
In order to get exactly 100 samples from the (only) detected logic ana‐
lyzer hardware, run the following command:
sigrok-cli --samples 100
If you want to sample data for 3 seconds, use:
sigrok-cli --time 3000
Alternatively, you can also use:
sigrok-cli --time 3s
To capture data from 4 probes lasting 100ms at 10 MHz starting at the
trigger condition 1:high, 2:rising, 3:low, 4:high, use:
sigrok-cli -d 0:samplerate=10m -O bits -p 1-4 --time 100 \
--wait-trigger --triggers 1=1,2=r,3=0,4=1
EXIT STATUS
sigrok-cli exits with 0 on success, 1 on most failures.
SEE ALSO
sigrok-qt(1), sigrok-gtk(1)
BUGS
Please report any bugs on the sigrok-devel mailing list
(sigrok-devel@lists.souceforge.net).
LICENSE
sigrok-cli is covered by the GNU General Public License (GPL). Some
portions are licensed under the "GPL v2 or later", some under "GPL v3
or later".
AUTHORS
Please see the individual source code files.
This manual page was written by Uwe Hermann <uwe@hermann-uwe.de>. It
is licensed under the terms of the GNU GPL (version 2 or later).
March 18, 2012 SIGROK-CLI(1)