'''sigrok-cli''' is a command-line frontend for sigrok.
'''sigrok-cli''' (sometimes abbreviated as "cli") is a command-line frontend for sigrok.


== manpage ==
It is licensed under the terms of the '''GNU GPL, version 3 or later'''.


== Getting the code ==
$ '''git clone git://sigrok.org/sigrok-cli'''
You can also [http://sigrok.org/gitweb/?p=sigrok-cli.git;a=tree browse the source code] via gitweb.
== Distribution packages ==
See [[Downloads#Binaries_and_distribution_packages|Downloads]].
== Building from source ==
See [[Building]].
== Usage tips ==
It is recommended to capture the data first and process them later. sigrok-cli is single-threaded application and too much load will overwhelm it resulting in early termination. For capturing, use binary output format (especially for high sample-rates). This is because other formats pose too big overhead.
$ sigrok-cli --driver saleae-logic-pro --channels 0=Vcc,1=CS,2=MISO,3=MOSI,4=CLK --output-file <file>.bin --output-format binary --config samplerate=50m --continuous
Even better, consider to use a buffer instead of direct write (even on SSD) and also compression.
$ sigrok-cli --driver saleae-logic-pro --channels 0=Vcc,1=CS,2=MISO,3=MOSI,4=CLK --output-format binary --config samplerate=50m --continuous | mbuffer | lz4 | pv > data.lz4q
== Manpage ==
<div class="toccolours mw-collapsible mw-collapsed" overflow:auto;">
<!-- Generated by: "LC_ALL=C nroff -man doc/sigrok-cli.1 | col -b". -->
<pre>
<pre>
SIGROK-CLI(1)                                                   SIGROK-CLI(1)
SIGROK-CLI(1)     General Commands Manual SIGROK-CLI(1)






NAME
NAME
       sigrok-cli - Command-line client for the sigrok logic analyzer software
       sigrok-cli - Command-line client for the sigrok software


SYNOPSIS
SYNOPSIS
       sigrok-cli [-hVlDdiIoOptwas] [-h|--help] [-V|--version] [-l|--loglevel
       sigrok-cli [OPTIONS] [COMMAND]
      level] [-D|--list-devices] [-d|--device device] [-i|--input-file  file‐
      name] [-I|--input-format format] [-o|--output-file filename] [-O|--out‐
      put-format format] [-p|--probes probelist] [-t|--triggers  triggerlist]
      [-w|--wait-trigger]    [-a|--protocol-decoders    list]    [-s|--proto‐
      col-decoder-stack stack] [--time ms] [--samples numsamples] [--continu‐
      ous]


DESCRIPTION
DESCRIPTION
       sigrok-cli  is  a  cross-platform  command  line utility for the sigrok
       sigrok-cli  is  a  cross-platform  command  line utility for the sigrok
       logic analyzer software.
       software.


       The command-line frontend for sigrok cannot display graphical output,
       It cannot display graphical output, but is  still  sufficient to run
      but is  still  sufficient to run through the whole process of hardware
      through the whole process of hardware initialization, acquisition, pro-
      initialization, acquisition, protocol decoding and saving the session.
      tocol decoding and saving the session.


       It is useful for running on remote or embedded systems, netbooks, PDAs,
       It is useful for running on remote or embedded systems, netbooks, PDAs,
Line 35: Line 56:
OPTIONS
OPTIONS
       -h, --help
       -h, --help
              Show a help text and exit.
      Show a help text and exit.


       -V, --version
       -V, --version
              Show sigrok-cli version, and information about supported hard‐
      Show sigrok-cli version and the versions of libraries used.
              ware drivers, input file formats, output file formats, and pro‐
 
              tocol decoders.
      -L, --list-supported
      Show information about supported hardware drivers, input file
      formats, output file formats, and protocol decoders.
 
      -d, --driver <drivername>
      A  driver  must always be selected (unless doing a global scan).
      Use the -L (--list-supported) option to get a list of  available
      drivers.
 
      Drivers  can  take  options,  in the form key=value separated by
      colons.


      -l, --loglevel <level>
      Drivers communicating with hardware via  a  serial  port always
              Set the libsigrok and libsigrokdecode loglevel. At  the moment
      need  the port specified as the conn option. For example, to use
              sigrok-cli doesn't  support setting the two loglevels indepen‐
      the Openbench Logic Sniffer:
              dently. The higher the number, the more  debug  output  will  be
 
              printed. Valid  loglevels  are  0  (NONE), 1 (ERR), 2 (WARN), 3
$ sigrok-cli --driver=ols:conn=/dev/ttyACM0 [...]
              (INFO), 4 (DBG), and 5 (SPEW).
 
      Some USB devices don't use a unique VendorID/ProductID  combina-
      tion, and thus need that specified as well. This also uses the
      conn option, using either VendorID.ProductID or bus.address:
 
      USB VendorID.ProductID example:
 
$ sigrok-cli --driver=uni-t-ut61e:conn=1a86.e008 [...]


      -D, --list-devices
      USB bus.address example:
              List all logic  analyzer  devices  found  on  the  system.  This
              actively scans for devices (USB, serial port, and others).


      -d, --device <device>
$ sigrok-cli --driver=uni-t-ut61e:conn=4.6 [...]
              The  device to use for acquisition. It can be specified by ID as
              reported by --list-devices, or by the  name  of  the  driver as
              reported by --version.


              A device can optionally be followed by a colon-separated list of
      -c, --config <deviceoption>
              device options, where each option takes the form key=value.  For
      A colon-separated list of device options, where each option
              example, to set the samplerate on the first device you might
      takes the form key=value.  For example, to set the samplerate to
              specify
      1MHz on a device supported by  the fx2lafw  driver,  you might
      specify


                $ sigrok-cli -d 0:samplerate=1m
$ sigrok-cli -d fx2lafw --config samplerate=1m [...]


              Samplerate is an option common to most devices. The argument
      Samplerate is an option common to most logic analyzers. The
              specifies the samplerate in Hz. You can also specify the sam‐
      argument specifies the samplerate in Hz. You can also specify
              plerate in kHz, MHz or GHz.  The following are all equivalent:
      the samplerate in kHz, MHz or GHz.  The following are all equiv-
      alent:


                $ sigrok-cli --samples 100 -d 0:samplerate=1000000
$ sigrok-cli -d fx2lafw --config samplerate=1000000 [...]


                $ sigrok-cli --samples 100 -d 0:samplerate=1m
$ sigrok-cli -d fx2lafw --config samplerate=1m [...]


                $ sigrok-cli --samples 100 -d "0:samplerate=1 MHz"
$ sigrok-cli -d fx2lafw --config "samplerate=1 MHz" [...]


       -i, --input-file <filename>
       -i, --input-file <filename>
              Load input from a file instead of a  hardware  device.  If the
      Load input from a file instead of a  hardware  device.  You  can
              --input-format option is not supplied, sigrok-cli attempts to
      specify  "-" to use stdin as input. If the --input-format option
              autodetect the file format of the input file.
      is not supplied, sigrok-cli attempts to autodetect the file for-
      mat of the input file.
 
      Example for loading a sigrok session file:
 
$ sigrok-cli -i example.sr [...]
 
      Example for loading a WAV file (autodetection of input format):
 
$ sigrok-cli -i example.wav [...]
 
      Example  for  loading  a VCD  file from stdin (autodetection of
      input format):
 
$ cat example.vcd | sigrok-cli -i - [...]


       -I, --input-format <format>
       -I, --input-format <format>
              When loading an input file, assume it's in the specified format.
      When loading an input file, assume it's in the specified format.
              If  this option is not supplied (in addition to --input-file),
      If  this option is not supplied (in addition to --input-file),
              sigrok-cli attempts to autodetect the file format of  the  input
      sigrok-cli attempts to autodetect the file format of  the  input
              file.
      file. Use  the  -L  (--list-supported)  option to see a list of
      available input formats.
 
      The format name may optionally be followed by a  colon-separated
      list of options, where each option takes the form key=value.
 
      Example for loading a binary file with options:
 
$ sigrok-cli -i example.bin
    -I binary:numchannels=4:samplerate=1mhz [...]


       -o, --output-file <filename>
       -o, --output-file <filename>
              Save  output  to a  file  instead  of writing it to stdout. The
      Save  output  to a  file  instead  of writing it to stdout. The
              default format used when saving is the sigrok session file  for‐
      default format used when saving is the sigrok session file  for-
              mat. This can be changed with the --output-format option.
      mat. This can be changed with the --output-format option.


      -O, --output-format <formatname>
      Example for saving data in the sigrok session format:
              Set the output format to use. Use the -V option to see a list of
              available output formats. The format name may optionally be fol‐
              lowed  by  a  colon-separated list of options, where each option
              takes the form key=value.


              Supported formats currently include bits,  hex,  ascii,  binary,
$ sigrok-cli [...] -o example.sr
              vcd, ols, gnuplot, chronovu-la8, and csv.


              The  bits  or hex formats, for an ASCII bit or ASCII hexadecimal
      -O, --output-format <format>
              display, can take a "width" option, specifying the number  of
      Set the output format to use. Use the -L (--list-supported)
              samples  (in  bits) to display per line. Thus hex:width=128 will
      option to see a list of available output formats.
              display 128 bits per line, in hexadecimal:


              1:ffff ffff ffff ffff ffff ffff ffff ffff
      The format name may optionally be followed by a  colon-separated
              2:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00
      list of options, where each option takes the form key=value.


              The lines always start  with the  probe number  (or name, if
      For example, the bits or hex formats, for an ASCII bit or ASCII
              defined), followed by a colon. If no format is specified, it
      hexadecimal display, can take a "width" option, specifying the
              defaults to bits:width=64, like this:
      number  of samples (in bitsto display per line. Thus -O
      hex:width=128 will display 128 bits per line, in hexadecimal:


              1:11111111 11111111 11111111 11111111 [...]
      0:ffff ffff ffff ffff ffff ffff ffff ffff
              2:11111111 00000000 11111111 00000000 [...]
      1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00


      -p, --probes <probelist>
      The lines always start with the  channel number (or  name,  if
              A comma-separated list of probes to be used in the session.
      defined),  followed  by  a  colon. If no format is specified, it
      defaults to bits:width=64, like this:


              The default is to use all the probes available on a device. You
      0:11111111 11111111 11111111 11111111 [...]
              can  name  a probe like this: 1=CLK. A range of probes can also
      1:11111111 00000000 11111111 00000000 [...]
              be given, in the form 1-5.


              Example:
      Example for saving data in the CSV format with options:


              $ sigrok-cli --samples 100 --probes 1=CLK,2-4,7
$ sigrok-cli [...] -o example.csv -O csv:dedup:header=false
              CLK:11111111 11111111 11111111 11111111 [...]
                2:11111111 11111111 11111111 11111111 [...]
                3:11111111 11111111 11111111 11111111 [...]
                4:11111111 11111111 11111111 11111111 [...]
                7:11111111 11111111 11111111 11111111 [...]


              The comma-separated list is processed from left to  right,  i.e.
      Notice that boolean options are true when no value  gets speci-
              items  farther to the right override previous items. For example
      fied.
              1=CS,1=MISO will set the name of probe 1 to MISO.


              Also, while 5=MOSI,6=MISO will only select probes 5 and 6, and
      -C, --channels <channellist>
              set  their  names   to   MISO  and MOSIthe command line
      A comma-separated list of channels to be used in the session.
              5=MOSI,6=MISO,1-8 will select probes 1-8 (including 5 and 6,  of
 
              course)but the  names specified for probes 5 and 6 will be
      Note  that  sigrok  always  names  the channels according to how
              reset to the defaults by the 1-8 probe selection.
      they're shown on the enclosure of the hardware.  If  your  logic
      analyzer numbers the channels 0-15, that's how you must specify
      them with this option. An oscilloscope's channels  would gener-
      ally be referred to as "CH1", "CH2", and so on. Use the --show
      option to see a list of channel names for your device.
 
      The default is to use all the channels available on  a  device.
      You  can name  a channel like this: 1=CLK. A range of channels
      can also be given, in the form 1-5.
 
      Example:
 
$ sigrok-cli --driver fx2lafw --samples 100
    --channels 1=CLK,2-4,7
      CLK:11111111 11111111 11111111 11111111 [...]
2:11111111 11111111 11111111 11111111 [...]
3:11111111 11111111 11111111 11111111 [...]
4:11111111 11111111 11111111 11111111 [...]
7:11111111 11111111 11111111 11111111 [...]
 
      The comma-separated list is processed from left to right, i.e.
      items farther to the right override previous items. For example
      1=CS,CS=MISO will set the name of channel 1 to MISO.
 
      -g, --channel-group <channel group>
      Specify the channel group to operate on. Some devices  organize
      channels into groups, the settings of which can only be changed
      as a group. The list of channel groupsif any, is displayed
      with the --show command.
 
      Examples:
 
$ sigrok-cli -g CH1 [...]
 
$ sigrok-cli -d demo -g Logic -c pattern=graycode [...]


       -t, --triggers <triggerlist>
       -t, --triggers <triggerlist>
              A  comma-separated  list of triggers to use, of the   form
      A  comma-separated  list of triggers to use, of the form <chan-
              <probe>=<trigger>.  You can use the name or number of the probe,
      nel>=<trigger>.  You can use the name or number of the channel,
              and the trigger itself is a series of characters:
      and the trigger itself is a series of characters:


              0 or 1: A low or high value on the pin.
      0 or 1: A low or high value on the pin.
              r or f: A rising or falling value on the pin. An r effectively
      r or f: A rising or falling value on the pin. An r effectively
              corresponds to 01.
      corresponds to 01.
              c: Any kind of change on a pin (either a rising or a falling
      e: Any kind of change on a pin (either a rising or a falling
              edge).
      edge).


              Not every device supports all of these trigger types. Use the -d
      Not every device supports all of these trigger types. Use the
              <device>  argument  (with no other arguments) to see which trig‐
      --show command to see which triggers your device supports.
              gers your device supports.


       -w, --wait-trigger
       -w, --wait-trigger
              Don't output any sample data (even  if  it's  actually  received
      Don't output any sample data (even  if  it's  actually  received
              from the logic analyzer) before the trigger condition is met. In
      from the hardware) before the trigger condition is met. In other
              other words, do not output any pre-trigger data. This option is
      words, do not output any pre-trigger data. This option is useful
              useful  if  you  don't  care about the data that came before the
      if  you  don't  care about the data that came before the trigger
              trigger (but the logic analyzer hardware delivers this  data to
      (but the hardware delivers this data to sigrok nonetheless).
              sigrok nonetheless).
 
      -P, --protocol-decoders <list>
      This option allows the user to specify a comma-separated list of
      protocol decoders  to be used in this session. The decoders are
      specified by their ID, as shown  in  the -L  (--list-supported)
      output.
 
      Example:
 
      $ sigrok-cli -i <file.sr> -P i2c
 
      Each protocol decoder can optionally be followed by a colon-sep-
      arated list  of  options,  where each option  takes  the  form
      key=value.
 
      Example:
 
      $ sigrok-cli -i <file.sr>
    -P uart:baudrate=115200:parity_type=odd
 
      The  list  of supported options depends entirely on the protocol
      decoder. Every protocol decoder has different  options  it  sup-
      ports.
 
      Any  "options"  specified  for  a protocol decoder which are not
      actually supported options, will be interpreted as being channel
      name/number assignments.
 
      Example:
 
      $ sigrok-cli -i <file.sr>
    -P spi:wordsize=9:miso=1:mosi=5:clk=3:cs=0
 
      In this example, wordsize is an option supported by the spi pro-
      tocol decoder. Additionally, the user tells sigrok to decode the
      SPI  protocol  using channel 1 as MISO signal for SPI, channel 5
      as MOSI, channel 3 as CLK, and channel 0 as CS# signal.
 
      Notice that the sigrok-cli application does  not support  "name
      matching".  Instead  it's  assumed  that the traces in the input
      stream match the order of the decoder's input signals,  or  that
      users  explicitly  specify  the  input channel to decoder signal
      mapping.
 
      When multiple decoders are specified in the same -P option, they
      will be stacked on top of each other in the specified order.
 
      Example:
 
      $ sigrok-cli -i <file.sr> -P i2c,eeprom24xx
      $ sigrok-cli -i <file.sr> -P uart:baudrate=31250,midi
 
      When multiple -P options are specified, each of them creates one
      decoder stack, which  executes  in  parallel to other  decoder
      stacks.
 
      Example:
 
      $ sigrok-cli -i <file.sr> -P uart:tx=D0:rx=D1 -P timing:data=D2
 
 
      -A, --protocol-decoder-annotations <annotations>
      By  default,  all  annotation output of all protocol decoders is
      shown. With this option a specific decoder's annotations can  be
      selected for display, by specifying the decoder ID:


      -a, --protocol-decoders <list>
      $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid -A i2c
              This option allows the user to specify a comma-separated list of
              protocol decoders to be used in this session. The  decoders  are
              specified by their ID, as shown in the --version output.


              Example:
      If  a  protocol decoder has multiple annotation classes, you can
      also specify which one of them to show by specifying  its  short
      description like this:


              $ sigrok-cli -i <file.sr> -a i2c
      $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
    -A i2c=data-read


              Each protocol decoder can optionally be followed by a colon-sep‐
      Select multiple annotation classes by separating them with a
              arated list of options, where  each  option  takes  the  form
      colon:
              key=value.


              Example:
      $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
    -A i2c=data-read:data-write


              $ sigrok-cli -i <file.sr> -a uart:baudrate=115200:parity=odd
      You can also select multiple protocol decoders, with an optional
      selected annotation class each, by separating them with commas:


              The  list  of supported options depends entirely on the protocol
      $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
              decoder. Every protocol decoder has different  options  it  sup‐
    -A i2c=data-read:data-write,edid
              ports.


              Any  "options"  specified  for  a protocol decoder which are not
      -M, --protocol-decoder-meta <pdname>
              actually supported options, will be interpreted as being probe
      When given, show protocol decoder meta output instead of annota-
              name/number assignments.
      tions. The argument is the name of the decoder whose meta out-
      put to show.


              Example:
      $ sigrok-cli -i <file.sr> -M i2c


              $ sigrok-cli -i <file.sr>
      Not every decoder generates meta output.
                            -a spi:wordsize=9:miso=1:mosi=5:sck=3:cs=0


              In this example, wordsize is an option supported by the spi pro‐
      -B, --protocol-decoder-binary <binaryspec>
              tocol decoder. Additionally, the user tells sigrok to decode the
      When  given,  decoder "raw" data of various kinds is written to
              SPI  protocol using probe 1 as MISO signal for SPI, probe 5 as
      stdout instead of annotations (this could be raw binary UART/SPI
              MOSI, probe 3 as SCK, and probe 0 as CS# signal.
      bytes, or WAV files, PCAP files, PNG files, or anything else;
      this is entirely dependent on the  decoder  and what  kinds  of
      binary output make sense for that decoder).


      -s, --protocol-decoder-stack <stack>
      No  other  information is printed to stdout, so this is suitable
              This option allows the user to specify a protocol decoder stack,
      for piping into other programs or saving to a file.
              i.e.  the way in which one protocol decoder's output gets piped
              into another protocol decoder.


              The decoders are specified by their ID, as shown in  the --ver‐
      Protocol decoders that support binary output publish a  list  of
              sion output. In addition to the -s option, all protocol decoders
      binary classes, for example the UART decoder might have "TX" and
              that are used in a stack, must also be specified (together  with
      "RX". To select TX for output, the argument to this option would
              their options, if any) using the -a parameter.
      be:


              Example:
      $ sigrok-cli -i <file.sr> -B uart=tx


              $ sigrok-cli -i <file.sr> -a i2c:sda=4,scl=7,rtc8564
      If only the protocol decoder is specified, without binary class,
                            -s i2c,rtc8564
      all classes are written to stdout:


              In  this example, the -s option specifies that the output of the
      $ sigrok-cli -i <file.sr> -B uart
              i2c decoder is piped into the rtc8564 decoder, i.e., the rtc8564
              decoder is stacked on top of the i2c decoder.


              The respective protocol decoder options and probe name/number
      (this is only useful in rare cases, generally you would specify
              assignments must be given using the -a option (you cannot spec‐
      a certain binary class you're interested in)
              ify them in the -s option).
 
      Not every decoder generates binary output.
 
      --protocol-decoder-samplenum
      When given, decoder annotations  will include sample numbers,
      too.  This allows consumers to receive machine  readable timing
      information.
 
      -l, --loglevel <level>
      Set  the libsigrok  and libsigrokdecode loglevel. At the moment
      sigrok-cli doesn't support setting the  two  loglevels  indepen-
      dently.  The  higher  the  number, the more debug output will be
      printed. Valid loglevels are:
 
      0  None
      1  Error
      2  Warnings
      3  Informational
      4  Debug
      5  Spew
 
      --show
      Show information about the selected option. For example, to  see
      options for a connected fx2lafw device:
 
      $ sigrok-cli --driver fx2lafw --show
 
      In  order to properly get device options for your hardware, some
      drivers might need a serial port specified:
 
      $ sigrok-cli --driver ols:conn=/dev/ttyACM0 --show
 
      This also works for protocol decoders, input modules and output
      modules:
 
      $ sigrok-cli --protocol-decoders i2c --show
      $ sigrok-cli --input-format csv --show
      $ sigrok-cli --output-format bits --show
 
      --scan Scan for devices that can be detected automatically.
 
      Example:
 
      $ sigrok-cli --scan
      The following devices were found:
      demo - Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0
      A1 A2 A3
      fx2lafw:conn=3.26 - CWAV USBee SX with 8 channels: 0 1 2 3 4  5
      6 7
 
      However, not  all devices are auto-detectable (e.g. serial port
      based ones).  For those you'll have to provide  a  conn option,
      see above.
 
      $ sigrok-cli --driver digitek-dt4000zc:conn=/dev/ttyUSB0 --scan
      The following devices were found:
      Digitek DT4000ZC with 1 channel: P1


       --time <ms>
       --time <ms>
              Sample for <ms> milliseconds, then quit. You can optionally fol‐
      Sample for <ms> milliseconds, then quit.
              low the number by s to state the number  of  seconds  to sample
 
              instead. For example, --time 2s will sample for two seconds.
      You can optionally follow the number by s to specify the time to
      sample in seconds.
 
      For example, --time 2s will sample for two seconds.


       --samples <numsamples>
       --samples <numsamples>
              Acquire <numsamples> samples, then quit.
      Acquire <numsamples> samples, then quit.
 
      You can optionally follow the number by k, m, or g  to  specify
      the  number  of samples in kilosamples, megasamples, or gigasam-
      ples, respectively.
 
      For example, --samples 3m will acquire 3000000 samples.
 
      --frames <numframes>
      Acquire <numframes> frames, then quit.


       --continuous
       --continuous
              Sample continuously until stopped. Not all devices support this.
      Sample continuously until stopped. Not all devices support this.
 
      --get <variable>
      Get the value of <variable> from the specified device and  print
      it.
 
      --set  Set  one or  more variables specified with the --config option,
      without doing any acquisition.


EXAMPLES
EXAMPLES
       In order to get exactly 100 samples from the (only) detected logic ana‐
       In order to get exactly 100 samples from the connected  fx2lafw-sup-
       lyzer hardware, run the following command:
       ported logic analyzer hardware, run the following command:


        sigrok-cli --samples 100
sigrok-cli --driver fx2lafw --samples 100


       If you want to sample data for 3 seconds, use:
       If you want to sample data for 3 seconds (3000 ms), use:


        sigrok-cli --time 3000
sigrok-cli --driver fx2lafw --time 3000


       Alternatively, you can also use:
       Alternatively, you can also use:


        sigrok-cli --time 3s
sigrok-cli --driver fx2lafw --time 3s
 
      To  capture  data  from the first 4 channels using the Openbench Logic
      Sniffer lasting 100ms at 10 MHz starting at the trigger condition
      0:high, 1:rising, 2:low, 3:high, use:


       To capture data from 4 probes lasting 100ms at 10 MHz starting  at  the
       sigrok-cli --driver ols:conn=/dev/ttyACM0 --config samplerate=10m \
      trigger condition 1:high, 2:rising, 3:low, 4:high, use:
      --output-format bits --channels 0-3 --wait-trigger \
      --triggers 0=1,1=r,2=0,3=1 --time 100


        sigrok-cli -d 0:samplerate=10m -O bits -p 1-4 --time 100 \
      To turn on internal logging on a Lascar EL-USB series device:
                    --wait-trigger --triggers 1=1,2=r,3=0,4=1
 
      sigrok-cli --driver lascar-el-usb:conn=10c4.0002 \
      --config datalog=on --set


EXIT STATUS
EXIT STATUS
Line 257: Line 481:


SEE ALSO
SEE ALSO
       sigrok-qt(1), sigrok-gtk(1)
       pulseview(1)


BUGS
BUGS
       Please   report   any   bugs   on   the   sigrok-devel   mailing   list
       Please report any bugs via Bugzilla (http://sigrok.org/bugzilla) or  on
      (sigrok-devel@lists.souceforge.net).
      the sigrok-devel mailing list (sigrok-devel@lists.souceforge.net).


LICENSE
LICENSE
       sigrok-cli is covered by the GNU General Public License (GPL). Some
       sigrok-cli is covered by the GNU General Public License (GPL). Some
       portions are licensed under the "GPL v2 or later", some under "GPL v3
       portions are licensed under the "GPL v2 or later", some under "GPL v3
       or later".
       or later".


Line 271: Line 495:
       Please see the individual source code files.
       Please see the individual source code files.


       This manual page was written by Uwe Hermann <uwe@hermann-uwe.de>.   It
       This manual page was written by Uwe Hermann <uwe@hermann-uwe.de>. It
       is licensed under the terms of the GNU GPL (version 2 or later).
       is licensed under the terms of the GNU GPL (version 2 or later).






                                March 18, 2012                  SIGROK-CLI(1)
      October 22, 2018 SIGROK-CLI(1)
</pre>
</pre>
</div>
== Screenshots ==
=== sigrok-cli in action: logic data, decoder output, analog data ===
[[File:Sigrok-cli-screenshot-1.png]]

Latest revision as of 09:09, 7 July 2023

sigrok-cli (sometimes abbreviated as "cli") is a command-line frontend for sigrok.

It is licensed under the terms of the GNU GPL, version 3 or later.

Getting the code

$ git clone git://sigrok.org/sigrok-cli

You can also browse the source code via gitweb.

Distribution packages

See Downloads.

Building from source

See Building.

Usage tips

It is recommended to capture the data first and process them later. sigrok-cli is single-threaded application and too much load will overwhelm it resulting in early termination. For capturing, use binary output format (especially for high sample-rates). This is because other formats pose too big overhead.

$ sigrok-cli --driver saleae-logic-pro --channels 0=Vcc,1=CS,2=MISO,3=MOSI,4=CLK --output-file <file>.bin --output-format binary --config samplerate=50m --continuous

Even better, consider to use a buffer instead of direct write (even on SSD) and also compression.

$ sigrok-cli --driver saleae-logic-pro --channels 0=Vcc,1=CS,2=MISO,3=MOSI,4=CLK --output-format binary --config samplerate=50m --continuous | mbuffer | lz4 | pv > data.lz4q

Manpage

SIGROK-CLI(1)		    General Commands Manual		 SIGROK-CLI(1)



NAME
       sigrok-cli - Command-line client for the sigrok software

SYNOPSIS
       sigrok-cli [OPTIONS] [COMMAND]

DESCRIPTION
       sigrok-cli  is  a  cross-platform  command  line utility for the sigrok
       software.

       It cannot display graphical output, but	is  still  sufficient  to  run
       through the whole process of hardware initialization, acquisition, pro-
       tocol decoding and saving the session.

       It is useful for running on remote or embedded systems, netbooks, PDAs,
       and  for  various  other  use-cases. It can display samples on standard
       output or save them in various file formats.

OPTIONS
       -h, --help
	      Show a help text and exit.

       -V, --version
	      Show sigrok-cli version and the versions of libraries used.

       -L, --list-supported
	      Show information about supported hardware  drivers,  input  file
	      formats, output file formats, and protocol decoders.

       -d, --driver <drivername>
	      A  driver  must always be selected (unless doing a global scan).
	      Use the -L (--list-supported) option to get a list of  available
	      drivers.

	      Drivers  can  take  options,  in the form key=value separated by
	      colons.

	      Drivers communicating with hardware via  a  serial  port	always
	      need  the port specified as the conn option. For example, to use
	      the Openbench Logic Sniffer:

		$ sigrok-cli --driver=ols:conn=/dev/ttyACM0 [...]

	      Some USB devices don't use a unique VendorID/ProductID  combina-
	      tion,  and  thus need that specified as well. This also uses the
	      conn option, using either VendorID.ProductID or bus.address:

	      USB VendorID.ProductID example:

		$ sigrok-cli --driver=uni-t-ut61e:conn=1a86.e008 [...]

	      USB bus.address example:

		$ sigrok-cli --driver=uni-t-ut61e:conn=4.6 [...]

       -c, --config <deviceoption>
	      A colon-separated list of  device  options,  where  each	option
	      takes the form key=value.  For example, to set the samplerate to
	      1MHz on a device supported by  the  fx2lafw  driver,  you  might
	      specify

		$ sigrok-cli -d fx2lafw --config samplerate=1m [...]

	      Samplerate  is  an  option  common  to most logic analyzers. The
	      argument specifies the samplerate in Hz. You  can  also  specify
	      the samplerate in kHz, MHz or GHz.  The following are all equiv-
	      alent:

		$ sigrok-cli -d fx2lafw --config samplerate=1000000 [...]

		$ sigrok-cli -d fx2lafw --config samplerate=1m [...]

		$ sigrok-cli -d fx2lafw --config "samplerate=1 MHz" [...]

       -i, --input-file <filename>
	      Load input from a file instead of a  hardware  device.  You  can
	      specify  "-" to use stdin as input. If the --input-format option
	      is not supplied, sigrok-cli attempts to autodetect the file for-
	      mat of the input file.

	      Example for loading a sigrok session file:

		$ sigrok-cli -i example.sr [...]

	      Example for loading a WAV file (autodetection of input format):

		$ sigrok-cli -i example.wav [...]

	      Example  for  loading  a	VCD  file from stdin (autodetection of
	      input format):

		$ cat example.vcd | sigrok-cli -i - [...]

       -I, --input-format <format>
	      When loading an input file, assume it's in the specified format.
	      If  this	option	is not supplied (in addition to --input-file),
	      sigrok-cli attempts to autodetect the file format of  the  input
	      file.  Use  the  -L  (--list-supported)  option to see a list of
	      available input formats.

	      The format name may optionally be followed by a  colon-separated
	      list of options, where each option takes the form key=value.

	      Example for loading a binary file with options:

		$ sigrok-cli -i example.bin
			     -I binary:numchannels=4:samplerate=1mhz [...]

       -o, --output-file <filename>
	      Save  output  to	a  file  instead  of writing it to stdout. The
	      default format used when saving is the sigrok session file  for-
	      mat. This can be changed with the --output-format option.

	      Example for saving data in the sigrok session format:

		$ sigrok-cli [...] -o example.sr

       -O, --output-format <format>
	      Set  the	output	format	to  use. Use the -L (--list-supported)
	      option to see a list of available output formats.

	      The format name may optionally be followed by a  colon-separated
	      list of options, where each option takes the form key=value.

	      For  example, the bits or hex formats, for an ASCII bit or ASCII
	      hexadecimal display, can take a "width" option,  specifying  the
	      number  of  samples  (in	bits)  to  display  per  line. Thus -O
	      hex:width=128 will display 128 bits per line, in hexadecimal:

	       0:ffff ffff ffff ffff ffff ffff ffff ffff
	       1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00

	      The lines always start with the  channel	number	(or  name,  if
	      defined),  followed  by  a  colon. If no format is specified, it
	      defaults to bits:width=64, like this:

	       0:11111111 11111111 11111111 11111111 [...]
	       1:11111111 00000000 11111111 00000000 [...]

	      Example for saving data in the CSV format with options:

		$ sigrok-cli [...] -o example.csv -O csv:dedup:header=false

	      Notice that boolean options are true when no value  gets	speci-
	      fied.

       -C, --channels <channellist>
	      A comma-separated list of channels to be used in the session.

	      Note  that  sigrok  always  names  the channels according to how
	      they're shown on the enclosure of the hardware.  If  your  logic
	      analyzer	numbers the channels 0-15, that's how you must specify
	      them with this option. An oscilloscope's channels  would	gener-
	      ally  be referred to as "CH1", "CH2", and so on.	Use the --show
	      option to see a list of channel names for your device.

	      The default is to use all the channels available	on  a  device.
	      You  can	name  a channel like this: 1=CLK.  A range of channels
	      can also be given, in the form 1-5.

	      Example:

		$ sigrok-cli --driver fx2lafw --samples 100
			     --channels 1=CLK,2-4,7
	       CLK:11111111 11111111 11111111 11111111 [...]
		 2:11111111 11111111 11111111 11111111 [...]
		 3:11111111 11111111 11111111 11111111 [...]
		 4:11111111 11111111 11111111 11111111 [...]
		 7:11111111 11111111 11111111 11111111 [...]

	      The comma-separated list is processed from left to  right,  i.e.
	      items  farther to the right override previous items. For example
	      1=CS,CS=MISO will set the name of channel 1 to MISO.

       -g, --channel-group <channel group>
	      Specify the channel group to operate on. Some  devices  organize
	      channels	into groups, the settings of which can only be changed
	      as a group. The list of channel groups,  if  any,  is  displayed
	      with the --show command.

	      Examples:

		$ sigrok-cli -g CH1 [...]

		$ sigrok-cli -d demo -g Logic -c pattern=graycode [...]

       -t, --triggers <triggerlist>
	      A  comma-separated  list	of triggers to use, of the form <chan-
	      nel>=<trigger>.  You can use the name or number of the  channel,
	      and the trigger itself is a series of characters:

	      0 or 1: A low or high value on the pin.
	      r  or  f: A rising or falling value on the pin. An r effectively
	      corresponds to 01.
	      e: Any kind of change on a pin (either a	rising	or  a  falling
	      edge).

	      Not  every  device  supports all of these trigger types. Use the
	      --show command to see which triggers your device supports.

       -w, --wait-trigger
	      Don't output any sample data (even  if  it's  actually  received
	      from the hardware) before the trigger condition is met. In other
	      words, do not output any pre-trigger data. This option is useful
	      if  you  don't  care about the data that came before the trigger
	      (but the hardware delivers this data to sigrok nonetheless).

       -P, --protocol-decoders <list>
	      This option allows the user to specify a comma-separated list of
	      protocol	decoders  to be used in this session. The decoders are
	      specified by their ID, as shown  in  the	-L  (--list-supported)
	      output.

	      Example:

	       $ sigrok-cli -i <file.sr> -P i2c

	      Each protocol decoder can optionally be followed by a colon-sep-
	      arated list  of  options,  where	each  option  takes  the  form
	      key=value.

	      Example:

	       $ sigrok-cli -i <file.sr>
			    -P uart:baudrate=115200:parity_type=odd

	      The  list  of supported options depends entirely on the protocol
	      decoder. Every protocol decoder has different  options  it  sup-
	      ports.

	      Any  "options"  specified  for  a protocol decoder which are not
	      actually supported options, will be interpreted as being channel
	      name/number assignments.

	      Example:

	       $ sigrok-cli -i <file.sr>
			    -P spi:wordsize=9:miso=1:mosi=5:clk=3:cs=0

	      In this example, wordsize is an option supported by the spi pro-
	      tocol decoder. Additionally, the user tells sigrok to decode the
	      SPI  protocol  using channel 1 as MISO signal for SPI, channel 5
	      as MOSI, channel 3 as CLK, and channel 0 as CS# signal.

	      Notice that the sigrok-cli application does  not	support  "name
	      matching".  Instead  it's  assumed  that the traces in the input
	      stream match the order of the decoder's input signals,  or  that
	      users  explicitly  specify  the  input channel to decoder signal
	      mapping.

	      When multiple decoders are specified in the same -P option, they
	      will be stacked on top of each other in the specified order.

	      Example:

	       $ sigrok-cli -i <file.sr> -P i2c,eeprom24xx
	       $ sigrok-cli -i <file.sr> -P uart:baudrate=31250,midi

	      When multiple -P options are specified, each of them creates one
	      decoder stack, which  executes  in  parallel  to	other  decoder
	      stacks.

	      Example:

	       $ sigrok-cli -i <file.sr> -P uart:tx=D0:rx=D1 -P timing:data=D2


       -A, --protocol-decoder-annotations <annotations>
	      By  default,  all  annotation output of all protocol decoders is
	      shown. With this option a specific decoder's annotations can  be
	      selected for display, by specifying the decoder ID:

	       $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid -A i2c

	      If  a  protocol decoder has multiple annotation classes, you can
	      also specify which one of them to show by specifying  its  short
	      description like this:

	       $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
			    -A i2c=data-read

	      Select  multiple	annotation  classes  by separating them with a
	      colon:

	       $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
			    -A i2c=data-read:data-write

	      You can also select multiple protocol decoders, with an optional
	      selected annotation class each, by separating them with commas:

	       $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid
			    -A i2c=data-read:data-write,edid

       -M, --protocol-decoder-meta <pdname>
	      When given, show protocol decoder meta output instead of annota-
	      tions.  The argument is the name of the decoder whose meta  out-
	      put to show.

	       $ sigrok-cli -i <file.sr> -M i2c

	      Not every decoder generates meta output.

       -B, --protocol-decoder-binary <binaryspec>
	      When  given,  decoder  "raw" data of various kinds is written to
	      stdout instead of annotations (this could be raw binary UART/SPI
	      bytes,  or  WAV  files, PCAP files, PNG files, or anything else;
	      this is entirely dependent on the  decoder  and  what  kinds  of
	      binary output make sense for that decoder).

	      No  other  information is printed to stdout, so this is suitable
	      for piping into other programs or saving to a file.

	      Protocol decoders that support binary output publish a  list  of
	      binary classes, for example the UART decoder might have "TX" and
	      "RX". To select TX for output, the argument to this option would
	      be:

	       $ sigrok-cli -i <file.sr> -B uart=tx

	      If only the protocol decoder is specified, without binary class,
	      all classes are written to stdout:

	       $ sigrok-cli -i <file.sr> -B uart

	      (this is only useful in rare cases, generally you would  specify
	      a certain binary class you're interested in)

	      Not every decoder generates binary output.

       --protocol-decoder-samplenum
	      When  given,  decoder  annotations  will include sample numbers,
	      too.  This allows consumers to receive machine  readable	timing
	      information.

       -l, --loglevel <level>
	      Set  the	libsigrok  and libsigrokdecode loglevel. At the moment
	      sigrok-cli doesn't support setting the  two  loglevels  indepen-
	      dently.  The  higher  the  number, the more debug output will be
	      printed. Valid loglevels are:

	      0   None
	      1   Error
	      2   Warnings
	      3   Informational
	      4   Debug
	      5   Spew

       --show
	      Show information about the selected option. For example, to  see
	      options for a connected fx2lafw device:

	       $ sigrok-cli --driver fx2lafw --show

	      In  order to properly get device options for your hardware, some
	      drivers might need a serial port specified:

	       $ sigrok-cli --driver ols:conn=/dev/ttyACM0 --show

	      This also works for protocol decoders, input modules and	output
	      modules:

	       $ sigrok-cli --protocol-decoders i2c --show
	       $ sigrok-cli --input-format csv --show
	       $ sigrok-cli --output-format bits --show

       --scan Scan for devices that can be detected automatically.

	      Example:

	       $ sigrok-cli --scan
	       The following devices were found:
	       demo - Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0
	      A1 A2 A3
	       fx2lafw:conn=3.26 - CWAV USBee SX with 8 channels: 0 1 2 3 4  5
	      6 7

	      However,	not  all devices are auto-detectable (e.g. serial port
	      based ones).  For those you'll have to provide  a  conn  option,
	      see above.

	       $ sigrok-cli --driver digitek-dt4000zc:conn=/dev/ttyUSB0 --scan
	       The following devices were found:
	       Digitek DT4000ZC with 1 channel: P1

       --time <ms>
	      Sample for <ms> milliseconds, then quit.

	      You can optionally follow the number by s to specify the time to
	      sample in seconds.

	      For example, --time 2s will sample for two seconds.

       --samples <numsamples>
	      Acquire <numsamples> samples, then quit.

	      You can optionally follow the number by k, m, or	g  to  specify
	      the  number  of samples in kilosamples, megasamples, or gigasam-
	      ples, respectively.

	      For example, --samples 3m will acquire 3000000 samples.

       --frames <numframes>
	      Acquire <numframes> frames, then quit.

       --continuous
	      Sample continuously until stopped. Not all devices support this.

       --get <variable>
	      Get the value of <variable> from the specified device and  print
	      it.

       --set  Set  one	or  more variables specified with the --config option,
	      without doing any acquisition.

EXAMPLES
       In order to get exactly 100 samples  from  the  connected  fx2lafw-sup-
       ported logic analyzer hardware, run the following command:

	 sigrok-cli --driver fx2lafw --samples 100

       If you want to sample data for 3 seconds (3000 ms), use:

	 sigrok-cli --driver fx2lafw --time 3000

       Alternatively, you can also use:

	 sigrok-cli --driver fx2lafw --time 3s

       To  capture  data  from	the first 4 channels using the Openbench Logic
       Sniffer lasting 100ms at 10 MHz starting at the trigger condition
	      0:high, 1:rising, 2:low, 3:high, use:

       sigrok-cli --driver ols:conn=/dev/ttyACM0 --config samplerate=10m \
	      --output-format bits --channels 0-3 --wait-trigger \
	      --triggers 0=1,1=r,2=0,3=1 --time 100

       To turn on internal logging on a Lascar EL-USB series device:

       sigrok-cli --driver lascar-el-usb:conn=10c4.0002 \
	      --config datalog=on --set

EXIT STATUS
       sigrok-cli exits with 0 on success, 1 on most failures.

SEE ALSO
       pulseview(1)

BUGS
       Please report any bugs via Bugzilla (http://sigrok.org/bugzilla) or  on
       the sigrok-devel mailing list (sigrok-devel@lists.souceforge.net).

LICENSE
       sigrok-cli  is  covered	by  the GNU General Public License (GPL). Some
       portions are licensed under the "GPL v2 or later", some under  "GPL  v3
       or later".

AUTHORS
       Please see the individual source code files.

       This  manual  page was written by Uwe Hermann <uwe@hermann-uwe.de>.  It
       is licensed under the terms of the GNU GPL (version 2 or later).



			       October 22, 2018 		 SIGROK-CLI(1)

Screenshots

sigrok-cli in action: logic data, decoder output, analog data

Sigrok-cli-screenshot-1.png