Difference between revisions of "Manson HCS-3xxx series"
Uwe Hermann (talk | contribs) m (→Protocol) |
(old link runs into 404, change to something that works for now) |
||
(6 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{Infobox power supply | {{Infobox power supply | ||
| image = [[File:Manson hcs3202.png|180px]] | | image = [[File:Manson hcs3202.png|180px]] | ||
| name = Manson HCS-3xxx | | name = Manson HCS-3xxx series | ||
| status = supported | | status = supported | ||
| source_code_dir = manson-hcs-3xxx | | source_code_dir = manson-hcs-3xxx | ||
Line 11: | Line 11: | ||
| connectivity = USB/serial | | connectivity = USB/serial | ||
| features = programmable presets, cycling functionality | | features = programmable presets, cycling functionality | ||
| website = [ | | website = [https://www.manson.com.hk/product-list-filter/?cat_id=37&series_value=,140, manson.com.hk] | ||
}} | }} | ||
The '''Manson HCS-3xxx''' | The '''Manson HCS-3xxx series''' are 1 channel switch-mode programmable power supplies with USB/serial connectivity. | ||
== Devices == | == Devices == | ||
Line 102: | Line 102: | ||
|- | |- | ||
| HCS-3302-USB | | HCS-3302-USB | ||
| | | [https://www.conrad.de/de/voltcraft-dpps-32-15-labornetzgeraet-einstellbar-1-32-vdc-0-15-a-480-w-usb-programmierbar-anzahl-ausgaenge-1-x-1086556.html DPPS-32-15] | ||
| style="text-align:center" | - | | style="text-align:center" | - | ||
| style="text-align:center" | 1-32 V | | style="text-align:center" | 1-32 V | ||
Line 174: | Line 174: | ||
|} | |} | ||
The voltage and current specs are rounded values from the manufacturer's specs. The devices might allow slightly higher values for voltage and current. The exact values read from the devices are available by listing the config keys ''' | The voltage and current specs are rounded values from the manufacturer's specs. The devices might allow slightly higher values for voltage and current. The exact values read from the devices are available by listing the config keys '''SR_CONF_VOLTAGE_TARGET''' and '''SR_CONF_CURRENT_LIMIT'''. | ||
The devices linked above are supported. The other devices might work, but are untested. If you have one of the unsupported devices and can test it, please contact [[ | The devices linked above are supported. The other devices might work, but are untested. If you have one of the unsupported devices and can test it, please contact us on [https://web.libera.chat/#sigrok #sigrok@libera.chat] or on the [https://lists.sourceforge.net/lists/listinfo/sigrok-devel mailing list]. | ||
Some other device series by the same manufacturer exist that use a different communication protocol. | Some other device series by the same manufacturer exist that use a different communication protocol. | ||
Line 190: | Line 190: | ||
|- | |- | ||
| | | SR_CONF_ENABLED | ||
| Device | | Device | ||
| Boolean on/off | | Boolean on/off | ||
Line 196: | Line 196: | ||
|- | |- | ||
| | | SR_CONF_VOLTAGE | ||
| Device | | Device | ||
| Double | | Double | ||
Line 202: | Line 202: | ||
|- | |- | ||
| | | SR_CONF_VOLTAGE_TARGET | ||
| Device | | Device | ||
| Double | | Double | ||
Line 208: | Line 208: | ||
|- | |- | ||
| | | SR_CONF_CURRENT | ||
| Device | | Device | ||
| Double | | Double | ||
Line 214: | Line 214: | ||
|- | |- | ||
| | | SR_CONF_CURRENT_LIMIT | ||
| Device | | Device | ||
| Double | | Double | ||
Line 242: | Line 242: | ||
| 3204\rOK\r | | 3204\rOK\r | ||
| Query model | | Query model | ||
| Four-digit model code, e.g. ''3202'' for the [[Manson HCS-3202|HCS-3202]]. | | Four-digit model code, e.g. ''3202'' for the [[Manson HCS-3202|HCS-3202]]. Some models also use model codes like ''HCS-3302''. | ||
|- | |- | ||
Line 288: | Line 288: | ||
* [http://www.reinhardweiss.de/german/sonstiges.htm#HCS reinhardweiss.de: Manson HCS-3204 info] (most of it also applies to the other devices in the series) | * [http://www.reinhardweiss.de/german/sonstiges.htm#HCS reinhardweiss.de: Manson HCS-3204 info] (most of it also applies to the other devices in the series) | ||
* [http://goughlui.com/?p=2927 goughlui.com: Review: Manson HCS-3102 1-36v/0-5A Switch-Mode Benchtop Power Supply] (most of it also applies to the other devices in the series) | * [http://goughlui.com/?p=2927 goughlui.com: Review: Manson HCS-3102 1-36v/0-5A Switch-Mode Benchtop Power Supply] (most of it also applies to the other devices in the series) | ||
* [http:// | * [http://files.elv.de/Assets/Produkte/10/1067/106766/Downloads/106766_labornetzgeraet_hcs3202_um.pdf ELV: HCS-3200/3202/3204 manual] (contains some more commands than the manufacturer's docs) | ||
[[Category:Device]] | [[Category:Device]] | ||
[[Category:Power supply]] | [[Category:Power supply]] | ||
[[Category:Supported]] | [[Category:Supported]] |
Latest revision as of 18:31, 10 June 2023
Status | supported |
---|---|
Source code | manson-hcs-3xxx |
Channels | 1 |
Voltage/current (CH1) | various |
Connectivity | USB/serial |
Features | programmable presets, cycling functionality |
Website | manson.com.hk |
The Manson HCS-3xxx series are 1 channel switch-mode programmable power supplies with USB/serial connectivity.
Devices
Manson | Conrad OEM | Peaktech OEM | Voltage range | Current range | Power | Comments |
---|---|---|---|---|---|---|
HCS-3100 | PPS-11810 | 1-18 V | 0-10 A | 180 W | ||
HCS-3102 | PPS-11360 | 1-36 V | 0-5 A | 180 W | ||
HCS-3104 | PPS-11603 | 1-60 V | 0-2.5 A | 150 W | ||
HCS-3150 | - | 1-18 V | 0-15 A | 270 W | ||
HCS-3200 | PPS-13610 | 1-18 V | 0-20 A | 360 W | ||
HCS-3202 | PPS-16005 | 1-36 V | 0-10 A | 360 W | ||
HCS-3204 | PPS-11815 | 1-60 V | 0-5 A | 300 W | ||
HCS-3300-USB | - | - | 1-16 V | 0-30 A | 480 W | |
HCS-3302-USB | DPPS-32-15 | - | 1-32 V | 0-15 A | 480 W | |
HCS-3304-USB | - | - | 1-60 V | 0-8 A | 480 W | |
HCS-3400-USB | - | PeakTech 1565 | 1-16 V | 0-40 A | 600 W | |
HCS-3402-USB | - | PeakTech 1575 | 1-32 V | 0-20 A | 600 W? | |
HCS-3404-USB | - | - | 1-60 V | 0-10 A | 600 W | |
HCS-3600-USB | - | PeakTech 1580 | 1-16 V | 0-60 A | 750 W | |
HCS-3602-USB | - | PeakTech 1580 | 1-30 V | 0-30 A | 900 W | |
HCS-3604-USB | - | - | 1-60 V | 0-15 A | 900 W |
The voltage and current specs are rounded values from the manufacturer's specs. The devices might allow slightly higher values for voltage and current. The exact values read from the devices are available by listing the config keys SR_CONF_VOLTAGE_TARGET and SR_CONF_CURRENT_LIMIT.
The devices linked above are supported. The other devices might work, but are untested. If you have one of the unsupported devices and can test it, please contact us on #sigrok@libera.chat or on the mailing list.
Some other device series by the same manufacturer exist that use a different communication protocol.
Config keys
Function | Target | Parameters | Comments |
---|---|---|---|
SR_CONF_ENABLED | Device | Boolean on/off | Get: Query output status. Set: Switch output on or off. Power-on default is on. |
SR_CONF_VOLTAGE | Device | Double | Get: Query output voltage. Updated only if sampling is active! |
SR_CONF_VOLTAGE_TARGET | Device | Double | List: Get 3-tuple (min, max, step) for output voltage range. Get: Get output voltage limit. Set: Set output voltage limit. |
SR_CONF_CURRENT | Device | Double | Get: Query output current. Updated only if sampling is active! |
SR_CONF_CURRENT_LIMIT | Device | Double | List: Get 3-tuple (min, max, step) for output current range. Get: Get output current limit. Set: Set output current limit. |
See also Programmable power supply!
Protocol
The devices use an ASCII-based protocol over a USB-to-serial link.
All commands and replies end with a carriage return (\r) character.
Some versions of the protocol description in manuals are incomplete or even erroneous.
Command | Reply | Description | Comments |
---|---|---|---|
GMOD\r | 3204\rOK\r | Query model | Four-digit model code, e.g. 3202 for the HCS-3202. Some models also use model codes like HCS-3302. |
GETD\r | VVVVCCCCS\rOK\r | Query displayed voltage, current and mode. | Four-digit voltage, e.g. 12.34; four-digit current, e.g. 12.34; status 0=constant voltage, 1=constant current. |
SOUTn\r | OK\r | Disable output | Output on=0 (power-on default), off=1 |
SESS\r | OK\r | Disable keyboard | Seems to time out after about 5 seconds. |
ENDS\r | OK\r | Enable keyboard | When disabled with SESS. |
VOLTnnn\r | OK\r | Set voltage to nn.n. | |
CURRnnn\r | OK\r | Set current to nn.n or n.nn (model-dependent!). |
Resources
- Vendor control software (HCS_PC_software_v0_9.rar)
- Vendor Labview driver (HCS_labview_high_current_v0_1.rar)
- reinhardweiss.de: Manson HCS-3204 info (most of it also applies to the other devices in the series)
- goughlui.com: Review: Manson HCS-3102 1-36v/0-5A Switch-Mode Benchtop Power Supply (most of it also applies to the other devices in the series)
- ELV: HCS-3200/3202/3204 manual (contains some more commands than the manufacturer's docs)