Difference between revisions of "Agilent 54600 Series"

From sigrok
Jump to navigation Jump to search
(Add categories)
Line 2: Line 2:
| image              =  [[File:Agilent_5622A_Front.jpg|180px]]
| image              =  [[File:Agilent_5622A_Front.jpg|180px]]
| name                = Agilent 54600 series
| name                = Agilent 54600 series
| status              = unsupported
| status              = Not Supported‏‎
| source_code_dir    = ?
| source_code_dir    = ?
| channels            = 2-4 analog, 16 digital (D models only)
| channels            = 2-4 analog, 16 digital (D models only)
Line 15: Line 15:
| website            = [https://www.keysight.com/en/pd-1000000810%3Aepsg%3Apro-pn-54622A Keysight Technologies]
| website            = [https://www.keysight.com/en/pd-1000000810%3Aepsg%3Apro-pn-54622A Keysight Technologies]
}}
}}
== Protocol ==
Communication with the 54600 Series is over the RS232 port on the back, or via the floppy drive. The RS232 protocol [https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf is described in the Programmer's Guide]


== Models ==
== Models ==
Line 103: Line 99:
| 1 M, 50
| 1 M, 50
|}
|}
== Protocol ==
Communication with the 54600 Series is over the RS232 port on the back, or via the floppy drive. The RS232 protocol [https://literature.cdn.keysight.com/litweb/pdf/54622-97038.pdf is described in the Programmer's Guide.]


== Resources ==
== Resources ==
Line 111: Line 112:
* [https://literature.cdn.keysight.com/litweb/pdf/54642-97004.pdf Agilent 54640-Series Service Guide]
* [https://literature.cdn.keysight.com/litweb/pdf/54642-97004.pdf Agilent 54640-Series Service Guide]
* [https://literature.cdn.keysight.com/litweb/pdf/54622-97037.pdf Agilent 54620-Series Service Guide]
* [https://literature.cdn.keysight.com/litweb/pdf/54622-97037.pdf Agilent 54620-Series Service Guide]
[[Category:Device]]
[[Category:Logic analyzer]]
[[Category:Oscilloscope]]
[[Category:Mixed-signal oscilloscope]]
[[Category:Not Supported‏‎]]

Revision as of 19:40, 26 January 2019

Agilent 54600 series
Agilent 5622A Front.jpg
Status Not Supported‏‎
Source code ?
Channels 2-4 analog, 16 digital (D models only)
Samplerate 200-2000MSa/s (depending on model)
Analog bandwidth 60-500MHz (depending on model)
Vertical resolution 8bits
Triggers edge, pulse width, pattern, video, duration, sequence, CAN, USB, LIN, I2C, SPI
Input impedance 1MΩ‖13pF 300Vrms CAT I, 100Vrms CAT II. 50Ω‖13pF 5Vrms (depending on model)
Memory 4MSa-8MSa (mode/ch-dependent) (depending on model)
Display 7" raster monochrome CRT
Connectivity 3.5" 1.44MiB floppy, RS232, parallel port
Website Keysight Technologies

Models

Model Bandwidth (Hz) Max Sample Rate (Sa/s) Memory (MB) Digital Inputs Analog Inputs Input Impedance (Ω)
54621A 60 M 200 M 4 2 1 M
54621D 60 M 200 M 4 16 2 1 M
54622A 100 M 200 M 4 2 1 M
54622D 100 M 200 M 4 16 2 1 M
54624A 100 M 200 M 4 4 1 M
54641A 350 M 2 G 8 2 1 M, 50
54641D 350 M 2 G 8 16 2 1 M, 50
54642A 500 M 2 G 8 2 1 M, 50
54642D 500 M 2 G 8 16 2 1 M, 50


Protocol

Communication with the 54600 Series is over the RS232 port on the back, or via the floppy drive. The RS232 protocol is described in the Programmer's Guide.