Difference between revisions of "Sigrok-cli"
Jump to navigation
Jump to search
Uwe Hermann (talk | contribs) m |
Uwe Hermann (talk | contribs) (Update sigrok-cli manpage, document how to generate the wiki version.) |
||
Line 5: | Line 5: | ||
== manpage == | == manpage == | ||
<!-- Generated by: "LC_ALL=C nroff -man doc/sigrok-cli.1 | col -b". --> | |||
<pre> | <pre> | ||
SIGROK-CLI(1) General Commands Manual SIGROK-CLI(1) | SIGROK-CLI(1) General Commands Manual SIGROK-CLI(1) | ||
Line 22: | Line 22: | ||
It cannot display graphical output, but is still sufficient to run | It cannot display graphical output, but is still sufficient to run | ||
through the whole process of hardware initialization, acquisition, | through the whole process of hardware initialization, acquisition, pro- | ||
tocol decoding and saving the session. | tocol decoding and saving the session. | ||
Line 34: | Line 34: | ||
-V, --version | -V, --version | ||
Show sigrok-cli version, and information about supported | Show sigrok-cli version, and information about supported hard- | ||
ware drivers, input file formats, output file formats, and | ware drivers, input file formats, output file formats, and pro- | ||
tocol decoders. | tocol decoders. | ||
Line 51: | Line 51: | ||
$ sigrok-cli --driver=ols:conn=/dev/ttyACM0 | $ sigrok-cli --driver=ols:conn=/dev/ttyACM0 | ||
Some USB devices don't use a unique VendorID/ProductID | Some USB devices don't use a unique VendorID/ProductID combina- | ||
tion, and thus need that specified as well. This also uses the | tion, and thus need that specified as well. This also uses the | ||
conn option, using either VendorID.ProductID or bus.address: | conn option, using either VendorID.ProductID or bus.address: | ||
Line 67: | Line 67: | ||
Samplerate is an option common to most logic analyzers. The | Samplerate is an option common to most logic analyzers. The | ||
argument specifies the samplerate in Hz. You can also specify | argument specifies the samplerate in Hz. You can also specify | ||
the samplerate in kHz, MHz or GHz. The following are all | the samplerate in kHz, MHz or GHz. The following are all equiv- | ||
alent: | alent: | ||
Line 85: | Line 85: | ||
If this option is not supplied (in addition to --input-file), | If this option is not supplied (in addition to --input-file), | ||
sigrok-cli attempts to autodetect the file format of the input | sigrok-cli attempts to autodetect the file format of the input | ||
file. Use the -V option to see a list of available input | file. Use the -V option to see a list of available input for- | ||
mats. | mats. | ||
Line 93: | Line 93: | ||
-o, --output-file <filename> | -o, --output-file <filename> | ||
Save output to a file instead of writing it to stdout. The | Save output to a file instead of writing it to stdout. The | ||
default format used when saving is the sigrok session file | default format used when saving is the sigrok session file for- | ||
mat. This can be changed with the --output-format option. | mat. This can be changed with the --output-format option. | ||
Line 127: | Line 127: | ||
they're shown on the enclosure of the hardware. If your logic | they're shown on the enclosure of the hardware. If your logic | ||
analyzer numbers the channels 0-15, that's how you must specify | analyzer numbers the channels 0-15, that's how you must specify | ||
them with this option. An oscilloscope's channels would | them with this option. An oscilloscope's channels would gener- | ||
ally be referred to as "CH1", "CH2", and so on. Use the --show | ally be referred to as "CH1", "CH2", and so on. Use the --show | ||
option to see a list of channel names for your device. | option to see a list of channel names for your device. | ||
Line 157: | Line 157: | ||
-t, --triggers <triggerlist> | -t, --triggers <triggerlist> | ||
A comma-separated list of triggers to use, of the form < | A comma-separated list of triggers to use, of the form <chan- | ||
nel>=<trigger>. You can use the name or number of the channel, | nel>=<trigger>. You can use the name or number of the channel, | ||
and the trigger itself is a series of characters: | and the trigger itself is a series of characters: | ||
Line 164: | Line 164: | ||
r or f: A rising or falling value on the pin. An r effectively | r or f: A rising or falling value on the pin. An r effectively | ||
corresponds to 01. | corresponds to 01. | ||
e: Any kind of change on a pin (either a rising or a falling | |||
edge). | edge). | ||
Line 186: | Line 186: | ||
$ sigrok-cli -i <file.sr> -P i2c | $ sigrok-cli -i <file.sr> -P i2c | ||
Each protocol decoder can optionally be followed by a colon- | Each protocol decoder can optionally be followed by a colon-sep- | ||
arated list of options, where each option takes the form | arated list of options, where each option takes the form | ||
key=value. | key=value. | ||
Line 196: | Line 196: | ||
The list of supported options depends entirely on the protocol | The list of supported options depends entirely on the protocol | ||
decoder. Every protocol decoder has different options it | decoder. Every protocol decoder has different options it sup- | ||
ports. | ports. | ||
Line 208: | Line 208: | ||
-P spi:wordsize=9:miso=1:mosi=5:clk=3:cs=0 | -P spi:wordsize=9:miso=1:mosi=5:clk=3:cs=0 | ||
In this example, wordsize is an option supported by the spi | In this example, wordsize is an option supported by the spi pro- | ||
tocol decoder. Additionally, the user tells sigrok to decode the | tocol decoder. Additionally, the user tells sigrok to decode the | ||
SPI protocol using channel 1 as MISO signal for SPI, channel 5 | SPI protocol using channel 1 as MISO signal for SPI, channel 5 | ||
Line 220: | Line 220: | ||
given with the --protocol-decoders option. | given with the --protocol-decoders option. | ||
The decoders are specified by their ID, as shown in the -- | The decoders are specified by their ID, as shown in the --ver- | ||
sion output. In addition to the -S option, all protocol decoders | sion output. In addition to the -S option, all protocol decoders | ||
that are used in a stack, must also be specified (together with | that are used in a stack, must also be specified (together with | ||
Line 235: | Line 235: | ||
The respective protocol decoder options and channel name/number | The respective protocol decoder options and channel name/number | ||
assignments must be given using the -P option (you cannot | assignments must be given using the -P option (you cannot spec- | ||
ify them in the -S option). | ify them in the -S option). | ||
-A, --protocol-decoder-annotations <annotations> | -A, --protocol-decoder-annotations <annotations> | ||
By default, only the stack's topmost protocol decoder's | By default, only the stack's topmost protocol decoder's annota- | ||
tion output is shown. With this option another decoder's | tion output is shown. With this option another decoder's annota- | ||
tion can be selected for display, by specifying its ID: | tion can be selected for display, by specifying its ID: | ||
Line 264: | Line 264: | ||
-M, --protocol-decoder-meta <pdname> | -M, --protocol-decoder-meta <pdname> | ||
When given, show protocol decoder meta output instead of | When given, show protocol decoder meta output instead of annota- | ||
tions. The argument is the name of the decoder whose meta | tions. The argument is the name of the decoder whose meta out- | ||
put to show. | put to show. | ||
Line 301: | Line 301: | ||
-l, --loglevel <level> | -l, --loglevel <level> | ||
Set the libsigrok and libsigrokdecode loglevel. At the moment | Set the libsigrok and libsigrokdecode loglevel. At the moment | ||
sigrok-cli doesn't support setting the two loglevels | sigrok-cli doesn't support setting the two loglevels indepen- | ||
dently. The higher the number, the more debug output will be | dently. The higher the number, the more debug output will be | ||
printed. Valid loglevels are: | printed. Valid loglevels are: | ||
Line 323: | Line 323: | ||
$ sigrok-cli --driver ols:conn=/dev/ttyACM0 --show | $ sigrok-cli --driver ols:conn=/dev/ttyACM0 --show | ||
This also works for protocol decoders, input modules and output | |||
modules: | |||
$ sigrok-cli --protocol-decoders i2c --show | $ sigrok-cli --protocol-decoders i2c --show | ||
$ sigrok-cli --input-format csv --show | |||
$ sigrok-cli --output-format bits --show | |||
--scan Scan for devices that can be detected automatically. | --scan Scan for devices that can be detected automatically. | ||
Line 335: | Line 338: | ||
demo - Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0 | demo - Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0 | ||
A1 A2 A3 | A1 A2 A3 | ||
fx2lafw:conn=3.26 - CWAV USBee SX with 8 channels: 0 1 2 3 4 | fx2lafw:conn=3.26 - CWAV USBee SX with 8 channels: 0 1 2 3 4 5 | ||
6 7 | 6 7 | ||
However, not | However, not all devices are auto-detectable (e.g. serial port | ||
based ones). | based ones). For those you'll have to provide a conn option, | ||
see above. | see above. | ||
Line 357: | Line 360: | ||
Acquire <numsamples> samples, then quit. | Acquire <numsamples> samples, then quit. | ||
You can optionally follow the number by k, m, or g | You can optionally follow the number by k, m, or g to specify | ||
the | the number of samples in kilosamples, megasamples, or gigasam- | ||
ples, respectively. | ples, respectively. | ||
Line 368: | Line 371: | ||
--continuous | --continuous | ||
Sample continuously until stopped. Not all devices support this. | Sample continuously until stopped. Not all devices support this. | ||
--get <variable> | |||
Get the value of <variable> from the specified device and print | |||
it. | |||
--set Set one or more variables specified with the --config option, | --set Set one or more variables specified with the --config option, | ||
Line 373: | Line 380: | ||
EXAMPLES | EXAMPLES | ||
In order to get exactly 100 samples from the connected fx2lafw- | In order to get exactly 100 samples from the connected fx2lafw-sup- | ||
ported logic analyzer hardware, run the following command: | ported logic analyzer hardware, run the following command: | ||
Revision as of 17:49, 4 March 2016
sigrok-cli is a command-line frontend for sigrok.
It is licensed under the terms of the GNU GPL, version 3 or later.
manpage
SIGROK-CLI(1) General Commands Manual SIGROK-CLI(1) NAME sigrok-cli - Command-line client for the sigrok software SYNOPSIS sigrok-cli [OPTIONS] [COMMAND] DESCRIPTION sigrok-cli is a cross-platform command line utility for the sigrok software. It cannot display graphical output, but is still sufficient to run through the whole process of hardware initialization, acquisition, pro- tocol decoding and saving the session. It is useful for running on remote or embedded systems, netbooks, PDAs, and for various other use-cases. It can display samples on standard output or save them in various file formats. OPTIONS -h, --help Show a help text and exit. -V, --version Show sigrok-cli version, and information about supported hard- ware drivers, input file formats, output file formats, and pro- tocol decoders. -d, --driver <drivername> A driver must always be selected (unless doing a global scan). Use the -V option to get a list of available drivers. Drivers can take options, in the form key=value separated by colons. Drivers communicating with hardware via a serial port always need the port specified as the conn option. For example, to use the Openbench Logic Sniffer: $ sigrok-cli --driver=ols:conn=/dev/ttyACM0 Some USB devices don't use a unique VendorID/ProductID combina- tion, and thus need that specified as well. This also uses the conn option, using either VendorID.ProductID or bus.address: $ sigrok-cli --driver=uni-t-ut61e:conn=1a86.e008 -c, --config <device> A colon-separated list of device options, where each option takes the form key=value. For example, to set the samplerate to 1MHz on a device supported by the fx2lafw driver, you might specify $ sigrok-cli --driver=fx2lafw --config samplerate=1m Samplerate is an option common to most logic analyzers. The argument specifies the samplerate in Hz. You can also specify the samplerate in kHz, MHz or GHz. The following are all equiv- alent: $ sigrok-cli --driver fx2lafw --config samplerate=1000000 $ sigrok-cli --driver fx2lafw --config samplerate=1m $ sigrok-cli --driver fx2lafw --config "samplerate=1 MHz" -i, --input-file <filename> Load input from a file instead of a hardware device. If the --input-format option is not supplied, sigrok-cli attempts to autodetect the file format of the input file. -I, --input-format <format> When loading an input file, assume it's in the specified format. If this option is not supplied (in addition to --input-file), sigrok-cli attempts to autodetect the file format of the input file. Use the -V option to see a list of available input for- mats. The format name may optionally be followed by a colon-separated list of options, where each option takes the form key=value. -o, --output-file <filename> Save output to a file instead of writing it to stdout. The default format used when saving is the sigrok session file for- mat. This can be changed with the --output-format option. -O, --output-format <formatname> Set the output format to use. Use the -V option to see a list of available output formats. The format name may optionally be followed by a colon-separated list of options, where each option takes the form key=value. Supported formats currently include bits, hex, ascii, binary, vcd, ols, gnuplot, chronovu-la8, csv, and analog. The bits or hex formats, for an ASCII bit or ASCII hexadecimal display, can take a "width" option, specifying the number of samples (in bits) to display per line. Thus hex:width=128 will display 128 bits per line, in hexadecimal: 0:ffff ffff ffff ffff ffff ffff ffff ffff 1:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00 The lines always start with the channel number (or name, if defined), followed by a colon. If no format is specified, it defaults to bits:width=64, like this: 0:11111111 11111111 11111111 11111111 [...] 1:11111111 00000000 11111111 00000000 [...] -C, --channels <channellist> A comma-separated list of channels to be used in the session. Note that sigrok always names the channels according to how they're shown on the enclosure of the hardware. If your logic analyzer numbers the channels 0-15, that's how you must specify them with this option. An oscilloscope's channels would gener- ally be referred to as "CH1", "CH2", and so on. Use the --show option to see a list of channel names for your device. The default is to use all the channels available on a device. You can name a channel like this: 1=CLK. A range of channels can also be given, in the form 1-5. Example: $ sigrok-cli --driver fx2lafw --samples 100 --channels 1=CLK,2-4,7 CLK:11111111 11111111 11111111 11111111 [...] 2:11111111 11111111 11111111 11111111 [...] 3:11111111 11111111 11111111 11111111 [...] 4:11111111 11111111 11111111 11111111 [...] 7:11111111 11111111 11111111 11111111 [...] The comma-separated list is processed from left to right, i.e. items farther to the right override previous items. For example 1=CS,CS=MISO will set the name of channel 1 to MISO. -g, --channel-group <channel group> Specify the channel group to operate on. Some devices organize channels into groups, the settings of which can only be changed as a group. The list of channel groups, if any, is displayed with the --show command. -t, --triggers <triggerlist> A comma-separated list of triggers to use, of the form <chan- nel>=<trigger>. You can use the name or number of the channel, and the trigger itself is a series of characters: 0 or 1: A low or high value on the pin. r or f: A rising or falling value on the pin. An r effectively corresponds to 01. e: Any kind of change on a pin (either a rising or a falling edge). Not every device supports all of these trigger types. Use the --show command to see which triggers your device supports. -w, --wait-trigger Don't output any sample data (even if it's actually received from the hardware) before the trigger condition is met. In other words, do not output any pre-trigger data. This option is useful if you don't care about the data that came before the trigger (but the hardware delivers this data to sigrok nonetheless). -P, --protocol-decoders <list> This option allows the user to specify a comma-separated list of protocol decoders to be used in this session. The decoders are specified by their ID, as shown in the --version output. Example: $ sigrok-cli -i <file.sr> -P i2c Each protocol decoder can optionally be followed by a colon-sep- arated list of options, where each option takes the form key=value. Example: $ sigrok-cli -i <file.sr> -P uart:baudrate=115200:parity_type=odd The list of supported options depends entirely on the protocol decoder. Every protocol decoder has different options it sup- ports. Any "options" specified for a protocol decoder which are not actually supported options, will be interpreted as being channel name/number assignments. Example: $ sigrok-cli -i <file.sr> -P spi:wordsize=9:miso=1:mosi=5:clk=3:cs=0 In this example, wordsize is an option supported by the spi pro- tocol decoder. Additionally, the user tells sigrok to decode the SPI protocol using channel 1 as MISO signal for SPI, channel 5 as MOSI, channel 3 as CLK, and channel 0 as CS# signal. -S, --protocol-decoder-stack <stack> This option allows the user to specify a protocol decoder stack, i.e. the way in which one protocol decoder's output gets piped into another protocol decoder. If not specified, the stack will be set up in the same order in which the protocol decoders were given with the --protocol-decoders option. The decoders are specified by their ID, as shown in the --ver- sion output. In addition to the -S option, all protocol decoders that are used in a stack, must also be specified (together with their options, if any) using the -P parameter. Example: $ sigrok-cli -i <file.sr> -P i2c:sda=4:scl=7,rtc8564 -S i2c,rtc8564 In this example, the -S option specifies that the output of the i2c decoder is piped into the rtc8564 decoder, i.e., the rtc8564 decoder is stacked on top of the i2c decoder. The respective protocol decoder options and channel name/number assignments must be given using the -P option (you cannot spec- ify them in the -S option). -A, --protocol-decoder-annotations <annotations> By default, only the stack's topmost protocol decoder's annota- tion output is shown. With this option another decoder's annota- tion can be selected for display, by specifying its ID: $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid -A i2c If a protocol decoder has multiple annotations, you can also specify which one of them to show by specifying its short description like this: $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid -A i2c=data-read Select multiple annotations by separating them with a colon: $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid -A i2c=data-read:data-write You can also select multiple protocol decoders, with an optional selected annotation each, by separating them with commas: $ sigrok-cli -i <file.sr> -P i2c,i2cfilter,edid -A i2c=data-read:data-write,edid -M, --protocol-decoder-meta <pdname> When given, show protocol decoder meta output instead of annota- tions. The argument is the name of the decoder whose meta out- put to show. $ sigrok-cli -i <file.sr> -M i2c Not every decoder generates meta output. -B, --protocol-decoder-binary <binaryspec> When given, decoder "raw" data of various kinds is written to stdout instead of annotations (this could be raw binary UART/SPI bytes, or WAV files, PCAP files, PNG files, or anything else; this is entirely dependent on the decoder and what kinds of binary output make sense for that decoder). No other information is printed to stdout, so this is suitable for piping into other programs or saving to a file. Protocol decoders that support binary output publish a list of binary classes, for example the UART decoder might have "TX" and "RX". To select TX for output, the argument to this option would be: $ sigrok-cli -i <file.sr> -B uart=tx If only the protocol decoder is specified, without binary class, all classes are written to stdout: $ sigrok-cli -i <file.sr> -B uart (this is only useful in rare cases, generally you would specify a certain binary class you're interested in) Not every decoder generates binary output. -l, --loglevel <level> Set the libsigrok and libsigrokdecode loglevel. At the moment sigrok-cli doesn't support setting the two loglevels indepen- dently. The higher the number, the more debug output will be printed. Valid loglevels are: 0 None 1 Error 2 Warnings 3 Informational 4 Debug 5 Spew --show Show information about the selected option. For example, to see options for a connected fx2lafw device: $ sigrok-cli --driver fx2lafw --show In order to properly get device options for your hardware, some drivers might need a serial port specified: $ sigrok-cli --driver ols:conn=/dev/ttyACM0 --show This also works for protocol decoders, input modules and output modules: $ sigrok-cli --protocol-decoders i2c --show $ sigrok-cli --input-format csv --show $ sigrok-cli --output-format bits --show --scan Scan for devices that can be detected automatically. Example: $ sigrok-cli --scan The following devices were found: demo - Demo device with 12 channels: D0 D1 D2 D3 D4 D5 D6 D7 A0 A1 A2 A3 fx2lafw:conn=3.26 - CWAV USBee SX with 8 channels: 0 1 2 3 4 5 6 7 However, not all devices are auto-detectable (e.g. serial port based ones). For those you'll have to provide a conn option, see above. $ sigrok-cli --driver digitek-dt4000zc:conn=/dev/ttyUSB0 --scan The following devices were found: Digitek DT4000ZC with 1 channel: P1 --time <ms> Sample for <ms> milliseconds, then quit. You can optionally follow the number by s to specify the time to sample in seconds. For example, --time 2s will sample for two seconds. --samples <numsamples> Acquire <numsamples> samples, then quit. You can optionally follow the number by k, m, or g to specify the number of samples in kilosamples, megasamples, or gigasam- ples, respectively. For example, --samples 3m will acquire 3000000 samples. --frames <numframes> Acquire <numframes> frames, then quit. --continuous Sample continuously until stopped. Not all devices support this. --get <variable> Get the value of <variable> from the specified device and print it. --set Set one or more variables specified with the --config option, without doing any acquisition. EXAMPLES In order to get exactly 100 samples from the connected fx2lafw-sup- ported logic analyzer hardware, run the following command: sigrok-cli --driver fx2lafw --samples 100 If you want to sample data for 3 seconds (3000 ms), use: sigrok-cli --driver fx2lafw --time 3000 Alternatively, you can also use: sigrok-cli --driver fx2lafw --time 3s To capture data from the first 4 channels using the Openbench Logic Sniffer lasting 100ms at 10 MHz starting at the trigger condition 0:high, 1:rising, 2:low, 3:high, use: sigrok-cli --driver ols:conn=/dev/ttyACM0 --config samplerate=10m \ --output-format bits --channels 0-3 --wait-trigger \ --triggers 0=1,1=r,2=0,3=1 --time 100 To turn on internal logging on a Lascar EL-USB series device: sigrok-cli --driver lascar-el-usb:conn=10c4.0002 \ --config datalog=on --set EXIT STATUS sigrok-cli exits with 0 on success, 1 on most failures. SEE ALSO pulseview(1) BUGS Please report any bugs via Bugzilla (http://sigrok.org/bugzilla) or on the sigrok-devel mailing list (sigrok-devel@lists.souceforge.net). LICENSE sigrok-cli is covered by the GNU General Public License (GPL). Some portions are licensed under the "GPL v2 or later", some under "GPL v3 or later". AUTHORS Please see the individual source code files. This manual page was written by Uwe Hermann <uwe@hermann-uwe.de>. It is licensed under the terms of the GNU GPL (version 2 or later). May 04, 2014 SIGROK-CLI(1)