Difference between revisions of "Chroma 62000P series"

From sigrok
Jump to navigation Jump to search
 
(One intermediate revision by the same user not shown)
Line 22: Line 22:
  PROG:SAVE                          # Optional
  PROG:SAVE                          # Optional
  PROG:RUN ON
  PROG:RUN ON
==== Current limit vs max settable current ====
* ":SOUR:CURR" Set maximum output current (CC mode threshold)
* ":SOUR:CURR:LIM:HIGH" Limit the maximum current setting that device will accept

Latest revision as of 00:48, 17 May 2015

Chroma 62000P series
Sigrok logo no text transparent 512.png
Status in progress
Source code scpi-pps
Channels 1
Voltage/current (CH1) 0-100V / 0-100A
Connectivity USBTMC, RS232, LXI or GPIB optional
Website chromaate.com

Protocol

LIST Program example

PROG:SEL 1
PROG:MODE LIST
PROG:ADD 1
PROG:SEQ:SEL 1
PROG:SEQ 0,40,10,25,INF,0,0.100    # Type AUTO, 40V, 10V/s, 25A, INF A/s, TTL output, 100ms
PROG:SAVE                          # Optional
PROG:RUN ON

Current limit vs max settable current

  • ":SOUR:CURR" Set maximum output current (CC mode threshold)
  • ":SOUR:CURR:LIM:HIGH" Limit the maximum current setting that device will accept