{{Infobox power supply | {{Infobox power supply | ||
| image = | | image = [[File:Motech_LPS-301_logo.png|180px]] | ||
| name = Motech LPS-300 series | | name = Motech LPS-300 series | ||
| status = | | status = supported | ||
| source_code_dir = | | source_code_dir = motech-lps-30x | ||
| channels = 1/3 | | channels = 1/3 | ||
| channel1 = 0-30 V / 0- | | channel1 = 0-30 V / 0-3 A, model-dependant | ||
| channel2 = 0-30 V / 0- | | channel2 = 0-30 V / 0-3 A, model-dependant | ||
| channel3 = 3.3/5 V / 0- | | channel3 = 3.3/5 V / 0-3 A, model-dependant | ||
| channel4 = | | channel4 = | ||
| connectivity = RS232 | | connectivity = RS232 | ||
| features = output on/off, calibration | | features = output on/off, calibration | ||
| website = | | website = [http://power.motech.com.tw/ power.motech.com.tw] | ||
}} | }} | ||
The '''[[Motech]] LPS-300''' series of programmable power supplies consists of | The '''[[Motech]] LPS-300''' series of programmable power supplies consists of five 1-channel or 3-channel devices with optional RS232 connectivity. | ||
The devices were also sold as | The devices were also sold as '''Amrel LPS-301''' to '''LPS-305''' by '''American Reliance''' and partly under further brands, e.g. the '''LPS-305''' as '''Tecpel TPS-3025'''. | ||
== Specifications == | |||
The models differ only in the number of available channels, maximum voltage and maximum current output: | The models differ only in the number of available channels, maximum voltage and maximum current output: | ||
Line 24: | Line 25: | ||
|- | |- | ||
! Model | ! Model | ||
! Power | ! Power output | ||
! Channels | ! Channels | ||
! Voltage/ | ! Voltage/current | ||
! sigrok status | |||
|- | |- | ||
| [[Motech LPS-301|LPS-301]] | | [[Motech LPS-301|LPS-301]] | ||
| 30 W | | 30 W | ||
| 1 | | 1 | ||
| 30 V/1 A or 15 V/2 A | | 30 V/1 A or 15 V/2 A | ||
| bgcolor="lime" | Supported | |||
|- | |- | ||
| LPS-302 | | LPS-302 | ||
| 60 W | | 60 W | ||
| 1 | | 1 | ||
| 30 V/2 A or 15 V/4 A | | 30 V/2 A or 15 V/4 A | ||
| bgcolor="yellow" | Planned | |||
|- | |- | ||
| LPS-303 | | LPS-303 | ||
| 90 W | | 90 W | ||
| 1 | | 1 | ||
| 30 V/3 A | | 30 V/3 A | ||
| bgcolor="yellow" | Planned | |||
|- | |- | ||
| LPS-304 | | LPS-304 | ||
| 70 W | | 70 W | ||
| 3 | | 3 | ||
| ±30 V/1 A or ±15 V/2 A; 5 V/2 A | | ±30 V/1 A or ±15 V/2 A; 5 V/2 A | ||
| bgcolor="yellow" | Planned | |||
|- | |- | ||
| LPS-305 | | LPS-305 | ||
| 165 W | | 165 W | ||
| 3 | | 3 | ||
| ±30 V/2.5 A; 3.3 or 5 V/3 A | | ±30 V/2.5 A; 3.3 or 5 V/3 A | ||
| bgcolor="yellow" | Planned | |||
|} | |} | ||
The three-channel versions have the two main channels wired together for symmetric power supply, but the voltages can be set independantly, if desired. They can be set on or off only together. | The three-channel versions have the two main channels wired together for symmetric power supply, but the voltages can be set independantly, if desired. They can be set on or off only together. | ||
The ''planned'' models are prepared in the driver ''motech-lps-30x'' and can be implemented easily as soon as devices for testing get available. | |||
These specifications are common to all models: | These specifications are common to all models: | ||
{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable" | {| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable" | ||
|- | |- | ||
! style="text-align: left;" colspan="3" | 30 V | |- | ||
! style="text-align: left;" colspan="3" | 30 V channels | |||
|- | |- | ||
| style="width: 20em; text-align: left;" | | | style="width: 20em; text-align: left;" | | ||
| | | '''Voltage''' | ||
| | | '''Current''' | ||
|- | |- | ||
|- | |- | ||
| Programming | | Programming resolution | ||
| 10 mV | | 10 mV | ||
| 1 mA | | 1 mA | ||
|- | |- | ||
| Programming | | Programming accuracy | ||
| 0.05% + 20 mV | | 0.05% + 20 mV | ||
| 0.15% + 5 mA | | 0.15% + 5 mA | ||
|- | |- | ||
| Readback | | Readback accuracy | ||
| 0.1% + 20 mV | | 0.1% + 20 mV | ||
| 0.2% + 5 mA | | 0.2% + 5 mA | ||
Line 94: | Line 104: | ||
|- | |- | ||
| Load | | Load regulation | ||
| 0.001% + 1mV | | 0.001% + 1mV | ||
| 0.01% + 1mA | | 0.01% + 1mA | ||
Line 101: | Line 111: | ||
These specifications apply only to models having a 3.3V/5V output: | These specifications apply only to models having a 3.3V/5V output: | ||
{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable" | {| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable" | ||
|- | |- | ||
! style="text-align: left;" colspan="3" | 3.3/ | |- | ||
! style="text-align: left;" colspan="3" | 3.3/5 V channel | |||
|- | |- | ||
| style="width: 20em; text-align: left;" | | | style="width: 20em; text-align: left;" | | ||
| | | '''Voltage''' | ||
| | | '''Current''' | ||
|- | |- | ||
Line 117: | Line 128: | ||
|- | |- | ||
| Load | | Load regulation | ||
| 0.001% + 1mV | | 0.001% + 1mV | ||
| 0.01% + 1mA | | 0.01% + 1mA | ||
Line 125: | Line 136: | ||
The devices can be calibrated easily requiring nothing but a multimeter of sufficient precision. | The devices can be calibrated easily requiring nothing but a multimeter of sufficient precision. | ||
= Protocol = | == Protocol == | ||
The communication with the device is via an optional RS-232 port (Option 02). The port parameters are 2400 Baud, 8n1. | The communication with the device is via an optional RS-232 port (Option 02). The port parameters are 2400 Baud, 8n1. | ||
All commands are plain ASCII. All commands are terminated by \r, \n or \r\n. Another command sent before reception of the reply (usually ''OK'') will be ignored. It seems that trailing digits for numerical parameters can be | All commands are plain ASCII. All commands are terminated by \r, \n or \r\n. Another command sent before reception of the reply (usually ''OK'') will be ignored. It seems that trailing digits for numerical parameters can be omitted. | ||
{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable" | {| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable" | ||
|- | |- | ||
! | ! Command | ||
! Reply | ! Reply | ||
! Description | ! Description | ||
Line 139: | Line 151: | ||
| | BEEP(0|1|2|3) | | | BEEP(0|1|2|3) | ||
| OK | | OK | ||
| Beeper function 0: disable; 1: enable; 2: force alarm 3: | | Beeper function 0: disable; 1: enable; 2: force alarm (beeper test) 3: end force alarm. | ||
|- | |- | ||
Line 164: | Line 176: | ||
| | LOWA(0|1) | | | LOWA(0|1) | ||
| OK | | OK | ||
| CC output compensated 0=off; 1=on (what | | CC output compensated 0=off; 1=on (what does this setting do?) | ||
|- | |- | ||
| MODEL | | MODEL | ||
| \r\nLPS-␣␣␣␣ OK | | \r\nLPS-␣␣␣␣ OK | ||
| Get model number (reply seems to be | | Get model number (reply contains spaces instead of model no in FW 1.17, seems to be a bug) | ||
|- | |- | ||
Line 179: | Line 191: | ||
| STATUS | | STATUS | ||
| <decimal> OK | | <decimal> OK | ||
| Working status, bitwise encoding.<br/>Bit 0, channel 1 mode: 0: CV 1: CC.<br/>Bit 1, channel 2 mode: 0: CV 1: CC.<br/>Bit 3,2, tracking: 00: independant; 10: to channel 1; 11: to channel 2.<br/>Bit 4, digital output 3: 0: off; 1: on.<br/>Bit 5, digital output voltage: 0: 5 V; 1: 3.3 V.<br/>Bit 6, output 1/2: off; 1: on.<br/>Bit 7, output 3: 0: ok; 1: overloaded.<br/>Bit 8, Fan: 0: off; 1: on<br/>Bit 9, beeper: 0: | | Working status, bitwise encoding.<br/>Bit 0, channel 1 mode: 0: CV 1: CC.<br/>Bit 1, channel 2 mode: 0: CV 1: CC.<br/>Bit 3,2, tracking: 00: independant; 10: to channel 1; 11: to channel 2.<br/>Bit 4, digital output 3: 0: off; 1: on.<br/>Bit 5, digital output voltage: 0: 5 V; 1: 3.3 V.<br/>Bit 6, output 1/2: off; 1: on.<br/>Bit 7, output 3: 0: ok; 1: overloaded.<br/>Bit 8, Fan: 0: off/low; 1: on/high<br/>Bit 9, beeper: 0: disabled; 1: enabled. Corresponds to BEEP0/1.<br/>Bit 10, CC output compensated: 0: off; 1: on | ||
|- | |- | ||
Line 194: | Line 206: | ||
| VERSION | | VERSION | ||
| \r\nVer-1.17␣\r\n OK | | \r\nVer-1.17␣\r\n OK | ||
| Get version number.<br/> | | Get version number.<br/>'''Bug: Seems not to work while the output is active on LPS-301 1.17, no reply!''' | ||
|- | |- | ||
Line 204: | Line 216: | ||
| | VSET(1|2) dd.ddd | | | VSET(1|2) dd.ddd | ||
| OK | | OK | ||
| Set output voltage. Entering more than 3 post-dot digits will overwrite starting from the left!<br/>The specified resolution is 10 mV. However, the actual resolution seems to be slightly higher, possibly due to rounding during decimal to binary conversion or depending on calibration. | | Set output voltage. Entering more than 3 post-dot digits will overwrite starting from the left!<br/>The specified resolution is 10 mV. However, the actual resolution seems to be slightly higher, possibly due to rounding during decimal to binary conversion or depending on calibration. | ||
|- | |- | ||
Line 215: | Line 227: | ||
OK means \r\nOK\r\n. | OK means \r\nOK\r\n. | ||
= | == Commands == | ||
{|border="0" style="font-size: smaller" class="alternategrey sortable sigroktable" | |||
* | |- | ||
! Function | |||
! Target | |||
! Parameters | |||
! Comment | |||
|- | |||
| SR_CONF_OUTPUT_CHANNEL | |||
| Device | |||
| String Independent | Track1 | Track2 | |||
| In tracking mode the other main channel seems to follow the tracked channel. | |||
|- | |||
| SR_CONF_OUTPUT_VOLTAGE | |||
| Channel | |||
| Double 0-30.0 | |||
| Get: Query output voltage. Updated only if sampling is active! Channel 3 allows only 5 V or 3.3 and 5 V, depending on model! | |||
|- | |||
| SR_CONF_OUTPUT_VOLTAGE_MAX | |||
| Channel | |||
| Double 0-30.0 | |||
| Get: Get max. possible voltage. Set: Set output voltage. Channel 3 allows only 5 V or 3.3 and 5 V, depending on model! | |||
|- | |||
| SR_CONF_OUTPUT_CURRENT | |||
| Channel | |||
| Double 0.005-x.xxxx | |||
| Get: Query output current. Updated only if sampling is active! Channel 1 and 2 only, channel 3 is fixed! | |||
|- | |||
| SR_CONF_OUTPUT_CURRENT_MAX | |||
| Channel | |||
| Double 0.005-x.xxxx | |||
| Get: Get max. possible current. Set: Set output current. Channel 1 and 2 only, channel 3 is fixed! | |||
|- | |||
| SR_CONF_OUTPUT_ENABLED | |||
| Channel | |||
| Boolean on/off | |||
| Switch output on or off. Channels 1 and 2 are connected, accessing one will also set the other one. | |||
|- | |||
|} | |||
Additionally sampling commands are possible. | |||
== Resources == | |||
* [http://www.prz.rzeszow.pl/kpe/materialy/astadler/DAQWWW/Manuals/LPS304%20Instruction%20Manual.pdf LPS-301 - LPS-304 User Manual] | |||
* [http://www.motech.com.tw/tw/doc/instrument/LPS%20305%20user%20manual.pdf LPS-305 User Manual] ([http://www.programmablepower.com/products/amrel/LPS/LPS305%20Manual.pdf Amrel version]) | |||
* [http://www.transcat.com/PDF/wiz.pdf Datasheet] | |||
[[Category:Power supply]] | [[Category:Power supply]] | ||
[[Category: | [[Category:Supported]] |
Latest revision as of 14:54, 23 November 2014
Status | supported |
---|---|
Source code | motech-lps-30x |
Channels | 1/3 |
Voltage/current (CH1) | 0-30 V / 0-3 A, model-dependant |
Voltage/current (CH2) | 0-30 V / 0-3 A, model-dependant |
Voltage/current (CH3) | 3.3/5 V / 0-3 A, model-dependant |
Connectivity | RS232 |
Features | output on/off, calibration |
Website | power.motech.com.tw |
The Motech LPS-300 series of programmable power supplies consists of five 1-channel or 3-channel devices with optional RS232 connectivity.
The devices were also sold as Amrel LPS-301 to LPS-305 by American Reliance and partly under further brands, e.g. the LPS-305 as Tecpel TPS-3025.
Specifications
The models differ only in the number of available channels, maximum voltage and maximum current output:
Model | Power output | Channels | Voltage/current | sigrok status |
---|---|---|---|---|
LPS-301 | 30 W | 1 | 30 V/1 A or 15 V/2 A | Supported |
LPS-302 | 60 W | 1 | 30 V/2 A or 15 V/4 A | Planned |
LPS-303 | 90 W | 1 | 30 V/3 A | Planned |
LPS-304 | 70 W | 3 | ±30 V/1 A or ±15 V/2 A; 5 V/2 A | Planned |
LPS-305 | 165 W | 3 | ±30 V/2.5 A; 3.3 or 5 V/3 A | Planned |
The three-channel versions have the two main channels wired together for symmetric power supply, but the voltages can be set independantly, if desired. They can be set on or off only together.
The planned models are prepared in the driver motech-lps-30x and can be implemented easily as soon as devices for testing get available.
These specifications are common to all models:
30 V channels | ||
---|---|---|
Voltage | Current | |
Programming resolution | 10 mV | 1 mA |
Programming accuracy | 0.05% + 20 mV | 0.15% + 5 mA |
Readback accuracy | 0.1% + 20 mV | 0.2% + 5 mA |
Ripple (10 Hz to 20 MHz) | 1 mV rms / 10 mV p-p | 10 mA rms |
Load regulation | 0.001% + 1mV | 0.01% + 1mA |
These specifications apply only to models having a 3.3V/5V output:
3.3/5 V channel | ||
---|---|---|
Voltage | Current | |
Ripple (10Hz to 20MHz) | 2 mVrms / 10mVp-p | 10mArms |
Load regulation | 0.001% + 1mV | 0.01% + 1mA |
The devices can be calibrated easily requiring nothing but a multimeter of sufficient precision.
Protocol
The communication with the device is via an optional RS-232 port (Option 02). The port parameters are 2400 Baud, 8n1.
All commands are plain ASCII. All commands are terminated by \r, \n or \r\n. Another command sent before reception of the reply (usually OK) will be ignored. It seems that trailing digits for numerical parameters can be omitted.
Command | Reply | Description |
---|---|---|
BEEP(0|1|2|3) | OK | Beeper function 0: disable; 1: enable; 2: force alarm (beeper test) 3: end force alarm. |
CALI(0|1|2) | ? | Calibration 0=end; 1=begin; 2=input parameter There seem to be no plausibility checks and the description is incomplete. Messing around with the calibration is strictly discouraged and can cause odd behaviour! |
HELP | (see right) OK | Output list of commands (several lines) |
IOUT(n) | d.dddd OK | Current readback |
ISET(n) d.dddd | OK | Set output current |
LOWA(0|1) | OK | CC output compensated 0=off; 1=on (what does this setting do?) |
MODEL | \r\nLPS-␣␣␣␣ OK | Get model number (reply contains spaces instead of model no in FW 1.17, seems to be a bug) |
OUT(0|1) | OK | Disable/enable output. OUT without a parameter seems to disable it. |
STATUS | <decimal> OK | Working status, bitwise encoding. Bit 0, channel 1 mode: 0: CV 1: CC. Bit 1, channel 2 mode: 0: CV 1: CC. Bit 3,2, tracking: 00: independant; 10: to channel 1; 11: to channel 2. Bit 4, digital output 3: 0: off; 1: on. Bit 5, digital output voltage: 0: 5 V; 1: 3.3 V. Bit 6, output 1/2: off; 1: on. Bit 7, output 3: 0: ok; 1: overloaded. Bit 8, Fan: 0: off/low; 1: on/high Bit 9, beeper: 0: disabled; 1: enabled. Corresponds to BEEP0/1. Bit 10, CC output compensated: 0: off; 1: on |
TRACK(0|1|2) | OK | Tracking 0=independant; 1=from channel 1; 2=from channel 2. Tracking seems to mean that channels 1 and 2 are synchronous on multi-channel models. |
VDD(0|3|5) | OK | Set ("digital") output 3 0=off; 1=3.3 V; 5=5 V |
VERSION | \r\nVer-1.17␣\r\n OK | Get version number. Bug: Seems not to work while the output is active on LPS-301 1.17, no reply! |
VOUT(1|2) | dd.ddd OK | Voltage readback |
VSET(1|2) dd.ddd | OK | Set output voltage. Entering more than 3 post-dot digits will overwrite starting from the left! The specified resolution is 10 mV. However, the actual resolution seems to be slightly higher, possibly due to rounding during decimal to binary conversion or depending on calibration. |
* | \r\nERROR\r\n OK | Error (invalid command). |
OK means \r\nOK\r\n.
Commands
Function | Target | Parameters | Comment |
---|---|---|---|
SR_CONF_OUTPUT_CHANNEL | Device | Track1 | Track2 | In tracking mode the other main channel seems to follow the tracked channel. |
SR_CONF_OUTPUT_VOLTAGE | Channel | Double 0-30.0 | Get: Query output voltage. Updated only if sampling is active! Channel 3 allows only 5 V or 3.3 and 5 V, depending on model! |
SR_CONF_OUTPUT_VOLTAGE_MAX | Channel | Double 0-30.0 | Get: Get max. possible voltage. Set: Set output voltage. Channel 3 allows only 5 V or 3.3 and 5 V, depending on model! |
SR_CONF_OUTPUT_CURRENT | Channel | Double 0.005-x.xxxx | Get: Query output current. Updated only if sampling is active! Channel 1 and 2 only, channel 3 is fixed! |
SR_CONF_OUTPUT_CURRENT_MAX | Channel | Double 0.005-x.xxxx | Get: Get max. possible current. Set: Set output current. Channel 1 and 2 only, channel 3 is fixed! |
SR_CONF_OUTPUT_ENABLED | Channel | Boolean on/off | Switch output on or off. Channels 1 and 2 are connected, accessing one will also set the other one. |
Additionally sampling commands are possible.