]> sigrok.org Git - libsigrok.git/blobdiff - README.devices
Don't set _POSIX_C_SOURCE for VXI/RPC related files.
[libsigrok.git] / README.devices
index c51e1d7227754de6f2e0f0b474820f3550334d53..935f797280c7c2925e7c055cc87e8e874e4ac5db 100644 (file)
@@ -10,7 +10,7 @@ Firmware
 --------
 
 Some devices supported by libsigrok need a firmware to be uploaded every time
-the device is connected to the PC (usually via USB), before it can be used. 
+the device is connected to the PC (usually via USB), before it can be used.
 
 The default location where libsigrok expects the firmware files is:
 
@@ -35,7 +35,7 @@ The following drivers/devices require a firmware upload upon connection:
 
  - fx2lafw: Logic analyzers based on the Cypress FX2(LP) chip need the
    firmware files from the 'sigrok-firmware-fx2lafw' repository/project.
-   The firmware is written from scratch and licensed under the GPLv2+.
+   The firmware is written from scratch and licensed under the GNU GPLv2+.
 
  - hantek-dso: The Hantek DSO-2090 (and other supported models of the same
    series of Hantek PC oscilloscopes) need firmware files.
@@ -47,19 +47,25 @@ The following drivers/devices require a firmware upload upon connection:
    These can be extracted from the vendor's Linux application using a tool
    from our 'sigrok-util' repository/project.
 
+ - sysclk-lwla: The Sysclk LWLA1034 requires various bitstream files.
+   These files are available from our 'sigrok-firmware' repository/project
+   under a license which allows us to redistribute them.
+
 The following drivers/devices do not need any firmware upload:
 
  - agilent-dmm
- - alsa
  - appa-55ii
+ - atten-pps3xxx
+ - brymen-bm86x
  - brymen-dmm
  - cem-dt-885x
  - center-3xx (including all subdrivers)
- - chronovu-la8
+ - chronovu-la
  - colead-slm
+ - conrad-digi-35-cpu
  - demo
  - fluke-dmm
- - gmc-mh-1x-2x
+ - gmc-mh-1x-2x (including all subdrivers)
  - hameg-hmo
  - ikalogic-scanalogic2
  - ikalogic-scanaplus
@@ -69,6 +75,7 @@ The following drivers/devices do not need any firmware upload:
  - mic-985xx (including all subdrivers)
  - norma-dmm
  - openbench-logic-sniffer
+ - pipistrello-ols
  - rigol-ds
  - serial-dmm (including all subdrivers)
  - teleinfo
@@ -76,6 +83,7 @@ The following drivers/devices do not need any firmware upload:
  - uni-t-dmm (including all subdrivers)
  - uni-t-ut32x
  - victor-dmm
+ - yokogawa-dlm
  - zeroplus-logic-cube
 
 
@@ -97,12 +105,14 @@ The following drivers/devices require a serial port specification:
 
  - agilent-dmm
  - appa-55ii
+ - atten-pps3xxx
  - brymen-dmm
  - cem-dt-885x
  - center-3xx (including all subdrivers)
  - colead-slm
+ - conrad-digi-35-cpu
  - fluke-dmm
- - gmc-mh-1x-2x
+ - gmc-mh-1x-2x (including all subdrivers)
  - hameg-hmo
  - link-mso19
  - mic-985xx (including all subdrivers)
@@ -115,9 +125,9 @@ The following drivers/devices require a serial port specification:
 
 The following drivers/devices do not require a serial port specification:
 
- - alsa
  - asix-sigma
- - chronovu-la8
+ - brymen-bm86x
+ - chronovu-la
  - demo
  - fx2lafw
  - hantek-dso
@@ -125,21 +135,24 @@ The following drivers/devices do not require a serial port specification:
  - ikalogic-scanaplus
  - kecheng-kc-330b
  - lascar-el-usb
+ - pipistrello-ols
  - rigol-ds (USBTMC or TCP)
  - saleae-logic16
+ - sysclk-lwla
  - uni-t-dmm (including all subdrivers)
  - uni-t-ut32x
  - victor-dmm
+ - yokogawa-dlm (USBTMC or TCP)
  - zeroplus-logic-cube
 
 
-Specifiying serial port parameters
-----------------------------------
+Specifying serial port parameters
+---------------------------------
 
 Every serial device's driver has default serial port parameters like baud
 rate, number of data bits, stop bits and handshake status. If a device requires
 different parameters, pass them as option "serialcomm" with the driver name.
-See libsigrok docs for function serial_set_paramstr() for complete specs.
+See libsigrok docs for the function serial_set_paramstr() for complete specs.
 
 Example:
 
@@ -287,71 +300,58 @@ a short list for convenience:
  - BBC Goertz Metrawatt M2110: Briefly press the "Start/Reset" button on the
    interface panel on top.
  - Digitek DT4000ZC: Briefly press the "RS232" button.
- - Gossen Metrawatt Metrahit devices: Power on the device with the "DATA"
-   button pressed. Additionally, Metrahit 2x devices must be configured for
-   interface "RS232".
+ - Gossen Metrawatt Metrahit 1x/2x devices, driver gmc-mh-1x-2x-rs232:
+   - Power on the device with the "DATA" button pressed.
+   - Metrahit 2x devices must be configured for the respective interface type.
+ - Gossen Metrawatt Metrahit 2x devices, driver gmc-mh-2x-bd232:
+   - 'BD232' interface:
+      The multimeter must be configured for the respective interface type.
+   - 'SI232-II' interface ("PC Mode"):
+      The multimeter must be configured for interface type 'BD232' (all),
+      'SI232 online' (28-29S) or 'SI232 store' (22-26x). The interface must
+      be configured to the same baud rate as the host (default 9600).
+      Multimeter and interface must be configured to the same address.
  - Norma DM950: If the interface doesn't work (e.g. USB-RS232 converter), power
    on the device with "FUNC" pressed (to power the interface from the DMM).
  - PCE PCE-DM32: Briefly press the "RS232" button.
  - RadioShack 22-812: Press and hold "SELECT" and "RANGE" together.
  - TekPower TP4000ZC: Briefly press the "RS232" button.
+ - Tenma 72-7750: Briefly press the "RS232C" button.
+ - UNI-T UT60G: Briefly press the "RS232C" button.
  - UNI-T UT61B/C/D: Press the "REL/RS232/USB" button for roughly 1 second.
+ - UNI-T UT71x: Press the "SEND/-/MAXMIN" button for roughly 1 second.
+   Briefly pressing the "EXIT" button leaves this mode again.
  - UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it
    appears that in practice you don't have to press the button (at least on
    some versions of the device), simply connect the device via USB.
  - V&A VA18B/VA40B: Keep the "Hz/DUTY" key pressed while powering on the DMM.
  - Victor 70C/86C: Press the "REL/RS232" button for roughly 1 second.
  - Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds.
+ - Voltcraft VC-870: Press the "REL/PC" button for roughly 1 second.
 
 
-ALSA driver
------------
-
-The 'alsa' driver can be used to sample analog data using a PC's soundcard.
-I.e. the sound card can act as a simple oscilloscope (with some limitations)
-using commercial or DIY "sound card scope probe" cables.
-
-Since ALSA is a Linux-specific sound system, this driver will inherently
-only compile and work on Linux.
-
-We might write additional drivers to make a similar functionality available
-on other OSes at some point.
-
-
-Link Instruments MSO-19
------------------------
-
-The driver for the Link Instruments MSO-19 mixed-signal oscilloscope (MSO)
-is currently using libudev (which is a library for the Linux-specific udev
-system). Thus, this driver can currently only compile and work on Linux.
+ChronoVu LA8/LA16 USB VID/PIDs
+------------------------------
 
-We plan to fix this though, so that it'll work on all other OSes, too.
-
-
-ChronoVu LA8 USB VID/PIDs
--------------------------
-
-The ChronoVu LA8 logic analyzer is available in two revisions. Previously,
-the LA8 shipped with a USB VID/PID of 0403:6001, which is the standard ID
+The ChronoVu LA8/LA16 logic analyzer is available in two revisions. Previously,
+the device shipped with a USB VID/PID of 0403:6001, which is the standard ID
 for FTDI FT232 USB chips.
 
-Since this made it hard to distinguish the LA8 from any other device
+Since this made it hard to distinguish the LA8/LA16 from any other device
 with this FTDI chip connected to the PC, the vendor later shipped the
-LA8 with a USB VID/PID of 0403:8867.
+device with a USB VID/PID of 0403:8867.
 
-The 'chronovu-la8' driver in libsigrok supports both VID/PID pairs and
-automatically finds devices with either VID/PID pair. However, currently
-the driver will assume any device with VID/PID 0403:6001 is a ChronoVu LA8.
+The 'chronovu-la' driver in libsigrok supports both VID/PID pairs and
+automatically finds devices with either VID/PID pair.
 
 
 OLS
 ---
 
-The Dangerous Prototypes Openbench Logic Sniffer (OLS) logic analyzer is
-supported by the 'ols' driver in libsigrok. This driver assumes a somewhat
-recent firmware has been flashed onto the OLS (it doesn't need a firmware
-upload every time it's attached via USB, since the firmware is stored in the
-device permanently).
+The Dangerous Prototypes Openbench Logic Sniffer (OLS) logic analyzer
+driver in libsigrok assumes a somewhat recent firmware has been flashed onto
+the OLS (it doesn't need a firmware upload every time it's attached via USB,
+since the firmware is stored in the device permanently).
 
 The most recent firmware version that is tested is 3.07.
 
@@ -369,20 +369,3 @@ Example:
 
  $ sigrok-cli --driver ols:conn=/dev/ttyACM0 ...
 
-
-Rigol DS oscilloscopes
-----------------------
-
-The 'rigol-ds' driver (for the Rigol DS series DSOs) currently uses the Linux
-usbtmc kernel driver. This means it can currently only be built and used on
-Linux (i.e., it's non-portable).
-
-The use of a kernel module also means it is dependent on the kernel version
-used, as well as on whether this specific module is available in the kernel.
-Additionally, the usbtmc kernel module has been known to have various bugs
-in some versions. These are some (but not all) drawbacks of using a kernel
-module as opposed to a libusb-based driver that works in user-space.
-
-We plan to change the driver to use the 'librevisa' user-space shared
-library (which uses libusb) soon, which will fix all these issues and make
-the driver portable at the same time.