]> sigrok.org Git - libsigrok.git/blobdiff - README.devices
Don't set _POSIX_C_SOURCE for VXI/RPC related files.
[libsigrok.git] / README.devices
index 0f089f105e31effdcd88226fa8fe9404ce4a5ebc..935f797280c7c2925e7c055cc87e8e874e4ac5db 100644 (file)
@@ -83,6 +83,7 @@ The following drivers/devices do not need any firmware upload:
  - uni-t-dmm (including all subdrivers)
  - uni-t-ut32x
  - victor-dmm
+ - yokogawa-dlm
  - zeroplus-logic-cube
 
 
@@ -141,11 +142,12 @@ The following drivers/devices do not require a serial port specification:
  - uni-t-dmm (including all subdrivers)
  - uni-t-ut32x
  - victor-dmm
+ - yokogawa-dlm (USBTMC or TCP)
  - zeroplus-logic-cube
 
 
-Specifiying serial port parameters
-----------------------------------
+Specifying serial port parameters
+---------------------------------
 
 Every serial device's driver has default serial port parameters like baud
 rate, number of data bits, stop bits and handshake status. If a device requires
@@ -317,12 +319,15 @@ a short list for convenience:
  - Tenma 72-7750: Briefly press the "RS232C" button.
  - UNI-T UT60G: Briefly press the "RS232C" button.
  - UNI-T UT61B/C/D: Press the "REL/RS232/USB" button for roughly 1 second.
+ - UNI-T UT71x: Press the "SEND/-/MAXMIN" button for roughly 1 second.
+   Briefly pressing the "EXIT" button leaves this mode again.
  - UNI-T UT325: Briefly press the "SEND" button (as per manual). However, it
    appears that in practice you don't have to press the button (at least on
    some versions of the device), simply connect the device via USB.
  - V&A VA18B/VA40B: Keep the "Hz/DUTY" key pressed while powering on the DMM.
  - Victor 70C/86C: Press the "REL/RS232" button for roughly 1 second.
  - Voltcraft VC-830: Press the "REL/PC" button for roughly 2 seconds.
+ - Voltcraft VC-870: Press the "REL/PC" button for roughly 1 second.
 
 
 ChronoVu LA8/LA16 USB VID/PIDs