]> sigrok.org Git - libsigrok.git/blob - src/dmm/bm52x.c
serial-dmm: add support for the Brymen BM820s family
[libsigrok.git] / src / dmm / bm52x.c
1 /*
2  * This file is part of the libsigrok project.
3  *
4  * Copyright (C) 2014 Aurelien Jacobs <aurel@gnuage.org>
5  * Copyright (C) 2019-2020 Gerhard Sittig <gerhard.sittig@gmx.net>
6  *
7  * This program is free software: you can redistribute it and/or modify
8  * it under the terms of the GNU General Public License as published by
9  * the Free Software Foundation, either version 3 of the License, or
10  * (at your option) any later version.
11  *
12  * This program is distributed in the hope that it will be useful,
13  * but WITHOUT ANY WARRANTY; without even the implied warranty of
14  * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
15  * GNU General Public License for more details.
16  *
17  * You should have received a copy of the GNU General Public License
18  * along with this program.  If not, see <http://www.gnu.org/licenses/>.
19  */
20
21 /**
22  * @file
23  *
24  * Brymen BM52x serial protocol parser. The USB protocol (for the cable)
25  * and the packet description (for the meter) were retrieved from:
26  * http://brymen.com/product-html/Download2.html
27  * http://brymen.com/product-html/PD02BM520s_protocolDL.html
28  * http://brymen.com/product-html/images/DownloadList/ProtocolList/BM520-BM520s_List/BM520-BM520s-10000-count-professional-dual-display-mobile-logging-DMMs-protocol.zip
29  *
30  * This parser was initially created for BM520s devices and tested with
31  * BM525s. The Brymen BM820s family of devices uses the same protocol,
32  * with just 0x82 instead of 0x52 in request packets and in the fixed
33  * fields of the responses. Which means that the packet parser can get
34  * shared among the BM520s and BM820s devices, but validity check needs
35  * to be individual, and the "wrong" packet request will end up without
36  * a response. Compared to BM520s the BM820s has dBm (in the protocol)
37  * and NCV (not seen in the protocol) and is non-logging (live only).
38  * BM820s support was tested with BM829s.
39  *
40  * The parser implementation was tested with a Brymen BM525s meter. Some
41  * of the responses differ from the vendor's documentation:
42  * - Recording session total byte counts don't start after the byte count
43  *   field, but instead include this field and the model ID (spans _every_
44  *   byte in the stream).
45  * - Recording session start/end markers are referred to as DLE, STX,
46  *   and ETX. Observed traffic instead sends 0xee, 0xa0, and 0xc0.
47  */
48
49 /*
50  * TODO
51  * - Some of the meter's functions and indications cannot get expressed
52  *   by means of sigrok MQ and flags terms. Some indicator's meaning is
53  *   unknown or uncertain, and thus their state is not evaluated.
54  *   - MAX-MIN, the span between extreme values, referred to as Vp-p.
55  *   - AVG is not available in BM525s and BM521s.
56  *   - LoZ, eliminating ghost voltages.
57  *   - LPF, low pass filter.
58  *   - low battery, emits sr_warn() but isn't seen in the feed.
59  *   - @, 4-20mA loop, % (main display, left hand side), Hi/Lo. Some of
60  *     these are in the vendor's documentation for the DMM packet but not
61  *     supported by the BM525s device which motivated the creation of the
62  *     parser's and was used to test its operation.
63  *   - It's a guess that the many undocumented bits (44 of them) are
64  *     related to the bargraph (40 ticks, overflow, sign, 6/10 scale).
65  *   - Should T1-T2 have a delta ("relative") decoration? But the meter's
66  *     "relative" feature is flexible, accepts any display value as the
67  *     reference, including min/max/diff when displayed upon activation.
68  *   - The "beep jack" displays "InEr" in the secondary display. This is
69  *     not caught here, no PC side message gets emitted.
70  * - Support for recordings is mostly untested. It was written to the
71  *   letter of the vendor documentation, but was not verified to work
72  *   for all of the many meter's modes including ranges. Inspection of
73  *   the full byte stream is necessary on one hand since random access
74  *   is not available, and useful on the other hand for consistency
75  *   checks.
76  */
77
78 #include <config.h>
79 #include <libsigrok/libsigrok.h>
80 #include "libsigrok-internal.h"
81 #include <math.h>
82 #include <string.h>
83 #include <strings.h>
84
85 #define LOG_PREFIX "brymen-bm52x"
86
87 /*
88  * DMM specific device options, and state keeping. All of it is related
89  * to recorded information in contrast to live readings. There also are
90  * four types of requesting HID reports that need to be sent.
91  */
92
93 static const uint32_t devopts[] = {
94         SR_CONF_CONTINUOUS,
95         SR_CONF_LIMIT_SAMPLES | SR_CONF_SET,
96         SR_CONF_LIMIT_MSEC | SR_CONF_SET,
97         SR_CONF_DATA_SOURCE | SR_CONF_GET | SR_CONF_SET | SR_CONF_LIST,
98 };
99
100 struct brymen_bm52x_state {
101         size_t sess_idx;
102         struct {
103                 uint8_t buff[2 * 32];
104                 size_t fill_pos;
105                 size_t read_pos;
106                 size_t remain;
107         } rsp;
108         const struct sr_dev_inst *sdi;
109 };
110
111 enum bm52x_reqtype {
112         REQ_LIVE_READ_520,
113         REQ_LIVE_READ_820,
114         REQ_REC_HEAD,
115         REQ_REC_NEXT,
116         REQ_REC_CURR,
117 };
118
119 #ifdef HAVE_SERIAL_COMM
120 static int bm52x_send_req(struct sr_serial_dev_inst *serial, enum bm52x_reqtype t)
121 {
122         static const uint8_t req_live_520[] = { 0x00, 0x00, 0x52, 0x66, };
123         static const uint8_t req_live_820[] = { 0x00, 0x00, 0x82, 0x66, };
124         static const uint8_t req_head[] = { 0x00, 0x00, 0x52, 0x88, };
125         static const uint8_t req_next[] = { 0x00, 0x00, 0x52, 0x89, };
126         static const uint8_t req_curr[] = { 0x00, 0x00, 0x52, 0x8a, };
127         static const uint8_t *req_bytes[] = {
128                 [REQ_LIVE_READ_520] = req_live_520,
129                 [REQ_LIVE_READ_820] = req_live_820,
130                 [REQ_REC_HEAD] = req_head,
131                 [REQ_REC_NEXT] = req_next,
132                 [REQ_REC_CURR] = req_curr,
133         };
134         static const size_t req_len = ARRAY_SIZE(req_live_520);
135
136         const uint8_t *p;
137         size_t l;
138         int ret;
139
140         if (t >= ARRAY_SIZE(req_bytes))
141                 return SR_ERR_ARG;
142         p = req_bytes[t];
143         l = req_len;
144         ret = serial_write_nonblocking(serial, p, l);
145         if (ret < 0)
146                 return ret;
147         if ((size_t)ret != l)
148                 return SR_ERR_IO;
149
150         return SR_OK;
151 }
152
153 SR_PRIV int sr_brymen_bm52x_packet_request(struct sr_serial_dev_inst *serial)
154 {
155         return bm52x_send_req(serial, REQ_LIVE_READ_520);
156 }
157
158 SR_PRIV int sr_brymen_bm82x_packet_request(struct sr_serial_dev_inst *serial)
159 {
160         return bm52x_send_req(serial, REQ_LIVE_READ_820);
161 }
162 #endif
163
164 /*
165  * The following code interprets live readings ("real-time download")
166  * which arrive in the "traditional" bitmap for LCD segments. Reading
167  * previously recorded measurements ("memory data sets") differs a lot
168  * and is handled in other code paths.
169  */
170
171 SR_PRIV gboolean sr_brymen_bm52x_packet_valid(const uint8_t *buf)
172 {
173         if (buf[16] != 0x52)
174                 return FALSE;
175         if (buf[17] != 0x52)
176                 return FALSE;
177         if (buf[18] != 0x52)
178                 return FALSE;
179         if (buf[19] != 0x52)
180                 return FALSE;
181
182         return TRUE;
183 }
184
185 SR_PRIV gboolean sr_brymen_bm82x_packet_valid(const uint8_t *buf)
186 {
187         if (buf[16] != 0x82)
188                 return FALSE;
189         if (buf[17] != 0x82)
190                 return FALSE;
191         if (buf[18] != 0x82)
192                 return FALSE;
193         if (buf[19] != 0x82)
194                 return FALSE;
195
196         return TRUE;
197 }
198
199 /*
200  * Data bytes in the DMM packet encode LCD segments in an unusual order
201  * (bgcpafed) and in an unusual position (bit 4 being the decimal point
202  * for some digits, an additional indicator for others). Fortunately all
203  * eight digits encode their segments in identical ways across the bytes.
204  *
205  * These routines convert LCD segments to characters, and a section of the
206  * DMM packet (which corresponds to the primary or secondary display) to
207  * the text representation of the measurement's value, before regular text
208  * to number conversion is applied, and SI units and their prefixes get
209  * derived from more indicators. It's important to keep in mind similar
210  * indicators exist for main and secondary displays in different locations.
211  */
212
213 static char brymen_bm52x_parse_digit(uint8_t b)
214 {
215         switch (b & ~0x10) {
216         /* Sign. */
217         case 0x40: /* ------g */ return '-';
218         /* Decimal digits. */
219         case 0xaf: /* abcdef- */ return '0';
220         case 0xa0: /* -bc---- */ return '1';
221         case 0xcb: /* ab-de-g */ return '2';
222         case 0xe9: /* abcd--g */ return '3';
223         case 0xe4: /* -bc--fg */ return '4';
224         case 0x6d: /* a-cd-fg */ return '5';
225         case 0x6f: /* a-cdefg */ return '6';
226         case 0xa8: /* abc---- */ return '7';
227         case 0xef: /* abcdefg */ return '8';
228         case 0xed: /* abcd-fg */ return '9';
229         /* Temperature units. */
230         case 0x0f: /* a--def- */ return 'C';
231         case 0x4e: /* a---efg */ return 'F';
232         /* OL condition, and diode and "Auto" modes. */
233         case 0x07: /* ---def- */ return 'L';
234         case 0xe3: /* -bcde-g */ return 'd';
235         case 0x20: /* --c---- */ return 'i';
236         case 0x63: /* --cde-g */ return 'o';
237         case 0xee: /* abc-efg */ return 'A';
238         case 0x23: /* --cde-- */ return 'u';
239         case 0x47: /* ---defg */ return 't';
240         /* Blank digit. */
241         case 0x00: /* ------- */ return '\0';
242         /* Invalid or unknown segment combination. */
243         default:
244                 sr_warn("Unknown encoding for digit: 0x%02x.", b);
245                 return '\0';
246         }
247 }
248
249 static int brymen_bm52x_parse_digits(const uint8_t *pkt, size_t pktlen,
250         char *txtbuf, float *value, char *temp_unit, int *digits, int signflag)
251 {
252         uint8_t byte;
253         char *txtptr, txtchar;
254         size_t pos;
255         int ret;
256
257         txtptr = txtbuf;
258         if (digits)
259                 *digits = INT_MIN;
260
261         if (pkt[0] & signflag)
262                 *txtptr++ = '-';
263         for (pos = 0; pos < pktlen; pos++) {
264                 byte = pkt[1 + pos];
265                 txtchar = brymen_bm52x_parse_digit(byte);
266                 if (pos == 3 && (txtchar == 'C' || txtchar == 'F')) {
267                         if (temp_unit)
268                                 *temp_unit = txtchar;
269                 } else if (txtchar) {
270                         *txtptr++ = txtchar;
271                         if (digits)
272                                 (*digits)++;
273                 }
274                 if (pos < 3 && (byte & 0x10)) {
275                         *txtptr++ = '.';
276                         if (digits)
277                                 *digits = 0;
278                 }
279         }
280         *txtptr = '\0';
281
282         if (digits && *digits < 0)
283                 *digits = 0;
284
285         ret = value ? sr_atof_ascii(txtbuf, value) : SR_OK;
286         if (ret != SR_OK) {
287                 sr_dbg("invalid float string: '%s'", txtbuf);
288                 return ret;
289         }
290
291         return SR_OK;
292 }
293
294 /*
295  * Extract the measurement value and its properties for one of the
296  * meter's displays from the DMM packet.
297  */
298 static void brymen_bm52x_parse(const uint8_t *buf, float *floatval,
299         struct sr_datafeed_analog *analog, size_t ch_idx)
300 {
301         char txtbuf[16], temp_unit;
302         int ret, digits, scale;
303         int is_diode, is_auto, is_no_temp, is_ol, is_db, is_main_milli;
304         int is_mm_max, is_mm_min, is_mm_avg, is_mm_dash;
305
306         temp_unit = '\0';
307         if (ch_idx == 0) {
308                 /*
309                  * Main display. Note that _some_ of the second display's
310                  * indicators are involved in the inspection of the _first_
311                  * display's measurement value. So we have to get the
312                  * second display's text buffer here, too.
313                  */
314                 (void)brymen_bm52x_parse_digits(&buf[7], 4, txtbuf,
315                         NULL, NULL, NULL, 0);
316                 is_diode = strcmp(txtbuf, "diod") == 0;
317                 is_auto = strcmp(txtbuf, "Auto") == 0;
318                 ret = brymen_bm52x_parse_digits(&buf[2], 4, txtbuf,
319                         floatval, &temp_unit, &digits, 0x80);
320                 is_ol = strstr(txtbuf, "0L") || strstr(txtbuf, "0.L");
321                 is_no_temp = strcmp(txtbuf, "---C") == 0;
322                 is_no_temp |= strcmp(txtbuf, "---F") == 0;
323                 if (ret != SR_OK && !is_ol)
324                         return;
325
326                 /* SI unit, derived from meter's current function. */
327                 is_db = buf[6] & 0x10;
328                 is_main_milli = buf[14] & 0x40;
329                 if (buf[14] & 0x20) {
330                         analog->meaning->mq = SR_MQ_VOLTAGE;
331                         analog->meaning->unit = SR_UNIT_VOLT;
332                         if (is_diode) {
333                                 analog->meaning->mqflags |= SR_MQFLAG_DIODE;
334                                 analog->meaning->mqflags |= SR_MQFLAG_DC;
335                         }
336                 } else if (buf[14] & 0x10) {
337                         analog->meaning->mq = SR_MQ_CURRENT;
338                         analog->meaning->unit = SR_UNIT_AMPERE;
339                 } else if (buf[14] & 0x01) {
340                         analog->meaning->mq = SR_MQ_CAPACITANCE;
341                         analog->meaning->unit = SR_UNIT_FARAD;
342                 } else if (buf[14] & 0x02) {
343                         analog->meaning->mq = SR_MQ_CONDUCTANCE;
344                         analog->meaning->unit = SR_UNIT_SIEMENS;
345                 } else if (buf[13] & 0x10) {
346                         analog->meaning->mq = SR_MQ_FREQUENCY;
347                         analog->meaning->unit = SR_UNIT_HERTZ;
348                 } else if (buf[7] & 0x01) {
349                         analog->meaning->mq = SR_MQ_CONTINUITY;
350                         analog->meaning->unit = SR_UNIT_OHM;
351                 } else if (buf[13] & 0x20) {
352                         analog->meaning->mq = SR_MQ_RESISTANCE;
353                         analog->meaning->unit = SR_UNIT_OHM;
354                 } else if (is_db && is_main_milli) {
355                         analog->meaning->mq = SR_MQ_POWER;
356                         analog->meaning->unit = SR_UNIT_DECIBEL_MW;
357                 } else if (buf[14] & 0x04) {
358                         analog->meaning->mq = SR_MQ_DUTY_CYCLE;
359                         analog->meaning->unit = SR_UNIT_PERCENTAGE;
360                 } else if ((buf[2] & 0x09) && temp_unit) {
361                         if (is_no_temp)
362                                 return;
363                         analog->meaning->mq = SR_MQ_TEMPERATURE;
364                         if (temp_unit == 'F')
365                                 analog->meaning->unit = SR_UNIT_FAHRENHEIT;
366                         else
367                                 analog->meaning->unit = SR_UNIT_CELSIUS;
368                 }
369
370                 /*
371                  * Remove the MIN/MAX/AVG indicators when all of them
372                  * are shown at the same time (indicating that recording
373                  * is active, but live readings are shown). This also
374                  * removes the MAX-MIN (V p-p) indication which cannot
375                  * get represented by SR_MQFLAG_* means.
376                  *
377                  * Keep the check conditions separate to simplify future
378                  * maintenance when Vp-p gets added. Provide the value of
379                  * currently unsupported modes just without flags (show
380                  * the maximum amount of LCD content on screen that we
381                  * can represent in sigrok).
382                  */
383                 is_mm_max = buf[1] & 0x01;
384                 is_mm_min = buf[1] & 0x08;
385                 is_mm_avg = buf[1] & 0x02;
386                 is_mm_dash = buf[1] & 0x04;
387                 if (is_mm_max && is_mm_min && is_mm_avg)
388                         is_mm_max = is_mm_min = is_mm_avg = 0;
389                 if (is_mm_max && is_mm_min && is_mm_dash)
390                         is_mm_max = is_mm_min = 0;
391                 if (is_mm_max && is_mm_min && !is_mm_dash)
392                         is_mm_max = is_mm_min = 0;
393
394                 /* AC/DC/Auto flags. Hold/Min/Max/Rel etc flags. */
395                 if (buf[1] & 0x20)
396                         analog->meaning->mqflags |= SR_MQFLAG_DC;
397                 if (buf[1] & 0x10)
398                         analog->meaning->mqflags |= SR_MQFLAG_AC;
399                 if (buf[20] & 0x10)
400                         analog->meaning->mqflags |= SR_MQFLAG_AUTORANGE;
401                 if (buf[20] & 0x80)
402                         analog->meaning->mqflags |= SR_MQFLAG_HOLD;
403                 if (is_mm_max)
404                         analog->meaning->mqflags |= SR_MQFLAG_MAX;
405                 if (is_mm_min)
406                         analog->meaning->mqflags |= SR_MQFLAG_MIN;
407                 if (is_mm_avg)
408                         analog->meaning->mqflags |= SR_MQFLAG_AVG;
409                 if (buf[2] & 0x40)
410                         analog->meaning->mqflags |= SR_MQFLAG_RELATIVE;
411
412                 /*
413                  * Remove the "dBm" indication's "m" indicator before the
414                  * SI unit's prefixes get inspected. Avoids an interaction
415                  * with the "milli" prefix. Strictly speaking BM525s does
416                  * not support dBm, but other models do and we may want
417                  * to share the protocol parser.
418                  */
419                 if (is_db)
420                         is_main_milli = 0;
421
422                 /* SI prefix. */
423                 scale = 0;
424                 if (buf[14] & 0x08) /* n */
425                         scale = -9;
426                 if (buf[14] & 0x80) /* u */
427                         scale = -6;
428                 if (is_main_milli) /* m */
429                         scale = -3;
430                 if (buf[13] & 0x80) /* k */
431                         scale = +3;
432                 if (buf[13] & 0x40) /* M */
433                         scale = +6;
434                 if (scale) {
435                         *floatval *= pow(10, scale);
436                         digits += -scale;
437                 }
438
439                 if (is_ol)
440                         *floatval = INFINITY;
441
442                 analog->encoding->digits  = digits;
443                 analog->spec->spec_digits = digits;
444         } else if (ch_idx == 1) {
445                 /*
446                  * Secondary display. Also inspect _some_ primary display
447                  * data, to determine the secondary display's validity.
448                  */
449                 (void)brymen_bm52x_parse_digits(&buf[2], 4, txtbuf,
450                         NULL, &temp_unit, NULL, 0x80);
451                 ret = brymen_bm52x_parse_digits(&buf[7], 4, txtbuf,
452                         floatval, NULL, &digits, 0x20);
453                 is_diode = strcmp(txtbuf, "diod") == 0;
454                 is_auto = strcmp(txtbuf, "Auto") == 0;
455                 is_no_temp = strcmp(txtbuf, "---C") == 0;
456                 is_no_temp |= strcmp(txtbuf, "---F") == 0;
457                 if (is_diode || is_auto)
458                         return;
459                 if (is_no_temp)
460                         return;
461
462                 /* SI unit. */
463                 if (buf[12] & 0x10) {
464                         analog->meaning->mq = SR_MQ_VOLTAGE;
465                         analog->meaning->unit = SR_UNIT_VOLT;
466                 } else if (buf[12] & 0x20) {
467                         analog->meaning->mq = SR_MQ_CURRENT;
468                         if (buf[11] & 0x10)
469                                 analog->meaning->unit = SR_UNIT_PERCENTAGE;
470                         else
471                                 analog->meaning->unit = SR_UNIT_AMPERE;
472                 } else if (buf[13] & 0x02) {
473                         analog->meaning->mq = SR_MQ_RESISTANCE;
474                         analog->meaning->unit = SR_UNIT_OHM;
475                 } else if (buf[12] & 0x02) {
476                         analog->meaning->mq = SR_MQ_CONDUCTANCE;
477                         analog->meaning->unit = SR_UNIT_SIEMENS;
478                 } else if (buf[12] & 0x01) {
479                         analog->meaning->mq = SR_MQ_CAPACITANCE;
480                         analog->meaning->unit = SR_UNIT_FARAD;
481                 } else if (buf[7] & 0x06) {
482                         if (strstr(txtbuf, "---"))
483                                 return;
484                         analog->meaning->mq = SR_MQ_TEMPERATURE;
485                         if (temp_unit == 'F')
486                                 analog->meaning->unit = SR_UNIT_FAHRENHEIT;
487                         else
488                                 analog->meaning->unit = SR_UNIT_CELSIUS;
489                 } else if (buf[13] & 0x01) {
490                         analog->meaning->mq = SR_MQ_FREQUENCY;
491                         analog->meaning->unit = SR_UNIT_HERTZ;
492                 } else if (buf[11] & 0x08) {
493                         analog->meaning->mq = SR_MQ_DUTY_CYCLE;
494                         analog->meaning->unit = SR_UNIT_PERCENTAGE;
495                 }
496
497                 /* DC/AC flags. */
498                 if (buf[7] & 0x80)
499                         analog->meaning->mqflags |= SR_MQFLAG_DC;
500                 if (buf[7] & 0x40)
501                         analog->meaning->mqflags |= SR_MQFLAG_AC;
502
503                 /* SI prefix. */
504                 scale = 0;
505                 if (buf[12] & 0x04) /* n */
506                         scale = -9;
507                 if (buf[12] & 0x40) /* u */
508                         scale = -6;
509                 if (buf[12] & 0x80) /* m */
510                         scale = -3;
511                 if (buf[13] & 0x04) /* k */
512                         scale = +3;
513                 if (buf[13] & 0x08) /* M */
514                         scale = +6;
515                 if (scale) {
516                         *floatval *= pow(10, scale);
517                         digits += -scale;
518                 }
519
520                 analog->encoding->digits  = digits;
521                 analog->spec->spec_digits = digits;
522         }
523
524         if (buf[7] & 0x08)
525                 sr_warn("Battery is low.");
526 }
527
528 SR_PRIV int sr_brymen_bm52x_parse(const uint8_t *buf, float *val,
529         struct sr_datafeed_analog *analog, void *info)
530 {
531         struct brymen_bm52x_info *info_local;
532         size_t ch_idx;
533
534         /*
535          * Scan a portion of the received DMM packet which corresponds
536          * to the caller's specified display. Then prepare to scan a
537          * different portion of the packet for another display. This
538          * routine gets called multiple times for one received packet.
539          */
540         info_local = info;
541         ch_idx = info_local->ch_idx;
542         brymen_bm52x_parse(buf, val, analog, ch_idx);
543         info_local->ch_idx = ch_idx + 1;
544
545         return SR_OK;
546 }
547
548 /*
549  * The above code paths support live readings ("real-time download").
550  * The below code paths support recordings ("memory data sets") which
551  * use different requests and responses and measurement representation
552  * which feels like "a different meter".
553  */
554
555 /*
556  * Developer notes, example data for recorded sessions.
557  *
558  * model
559  * 01
560  *    total bytes
561  *    e6 02 00
562  *             session count
563  *             01 00
564  *                   "DLE/STX" marker
565  *                   ee a0
566  *                         PS/NS addresses
567  *                         8a 03 a0 60 03 a0
568  *                                           func/sel/stat (DC-V, single display)
569  *                                           02 00 00
570  *                                                    session page length in bytes (3 * 240)
571  *                                                    d0 02 00
572  *                                                             main[/secondary] display data
573  *                                                             00 00 00 00
574  *                                                                          checksums and padding
575  *                                                                          7c 05 00 00 00 00 00 00
576  * 00 00 80 00 00 80 00 00 80 00 00 80 00 00 00 00 00 80 00 00 80 00 00 80  80 03 00 00 00 00 00 00
577  * 00 00 00 00 00 00 00 00 80 00 00 80 00 00 80 00 00 80 00 00 80 00 00 80  00 03 00 00 00 00 00 00
578  * ...
579  * 00 00 80 00 00 00 00 00 00 00 00 80 00 00 80 00 00 80 00 00 80 00 00 80  00 03 00 00 00 00 00 00
580  * 00 00 80 00 00 80 00 00 80 00 00 80 00 00 80 00 00 80 00 00
581  *                                                             "DLE/ETX" marker
582  *                                                             ee c0
583  *                                                                          ae 04 00 00 00 00 00 00
584  *
585  * - Checksum in bytes[25:24] is the mere sum of bytes[0:23].
586  * - Model ID is 0 or 1 -- does this translate to BM521s and BM525s?
587  * - Total byte count _includes_ everything starting at model ID.
588  * - There is no measurements count for a session page, but its length
589  *   in bytes, and a dual display flag, which lets us derive the count.
590  * - STX/ETX/DLE markers don't use the expected ASCII codes.
591  */
592
593 /*
594  * See vendor doc table 3.1 "Logging interval". Includes sub-1Hz rates,
595  * but also sub-1s intervals. Let's keep both presentations at hand.
596  */
597 static const struct {
598         unsigned int ival_secs;
599         unsigned int freq_rate;
600 } bm52x_rec_ivals[] = {
601         [ 0] = {   0, 20, },
602         [ 1] = {   0, 10, },
603         [ 2] = {   0,  2, },
604         [ 3] = {   1,  1, },
605         [ 4] = {   2,  0, },
606         [ 5] = {   3,  0, },
607         [ 6] = {   4,  0, },
608         [ 7] = {   5,  0, },
609         [ 8] = {  10,  0, },
610         [ 9] = {  15,  0, },
611         [10] = {  30,  0, },
612         [11] = {  60,  0, },
613         [12] = { 120,  0, },
614         [13] = { 180,  0, },
615         [14] = { 300,  0, },
616         [15] = { 600,  0, },
617 };
618
619 /*
620  * See vendor doc table 6 "Range bits". Temperature is not listed there
621  * but keeping it here unifies the processing code paths.
622  */
623 static const int bm52x_ranges_volt[16] = { 3, 2, 1, 0, };
624 static const int bm52x_ranges_millivolt[16] = { 5, 4, };
625 static const int bm52x_ranges_freq[16] = { 3, 2, 1, 0, -1, -2, -3, };
626 static const int bm52x_ranges_duty[16] = { 2, 1, };
627 static const int bm52x_ranges_ohm[16] = { 1, 0, -1, -2, -3, -4, };
628 static const int bm52x_ranges_cond[16] = { 11, };
629 static const int bm52x_ranges_cap[16] = { 11, 10, 9, 8, 7, 6, 5, };
630 static const int bm52x_ranges_diode[16] = { 3, };
631 static const int bm52x_ranges_temp[16] = { 0, };
632 static const int bm52x_ranges_amp[16] = { 3, 2, };
633 static const int bm52x_ranges_milliamp[16] = { 5, 4, };
634 static const int bm52x_ranges_microamp[16] = { 7, 6, };
635
636 /** Calculate checksum of four-HID-report responses (recordings). */
637 static uint16_t bm52x_rec_checksum(const uint8_t *b, size_t l)
638 {
639         uint16_t cs;
640
641         cs = 0;
642         while (l--)
643                 cs += *b++;
644
645         return cs;
646 }
647
648 /**
649  * Retrieve the first/next chunk of recording information.
650  * Support for live readings is theoretical, and unused/untested.
651  */
652 static int bm52x_rec_next_rsp(struct sr_serial_dev_inst *serial,
653         enum bm52x_reqtype req, struct brymen_bm52x_state *state)
654 {
655         uint8_t *b;
656         size_t l;
657         int ret;
658
659         /* Seed internal state when sending the HEAD request. */
660         if (req == REQ_REC_HEAD || req == REQ_LIVE_READ_520)
661                 memset(&state->rsp, 0, sizeof(state->rsp));
662
663         /* Move unprocessed content to the front. */
664         if (state->rsp.read_pos) {
665                 b = &state->rsp.buff[0];
666                 l = state->rsp.fill_pos - state->rsp.read_pos;
667                 if (l)
668                         memmove(&b[0], &b[state->rsp.read_pos], l);
669                 state->rsp.fill_pos -= state->rsp.read_pos;
670                 state->rsp.read_pos = 0;
671         }
672
673         /* Avoid queries for non-existing data. Limit NEXT requests. */
674         if (req == REQ_REC_NEXT && !state->rsp.remain)
675                 return SR_ERR_IO;
676
677         /* Add another response chunk to the read buffer. */
678         b = &state->rsp.buff[state->rsp.fill_pos];
679         l = req == REQ_LIVE_READ_520 ? 24 : 32;
680         if (sizeof(state->rsp.buff) - state->rsp.fill_pos < l)
681                 return SR_ERR_BUG;
682         ret = bm52x_send_req(serial, req);
683         if (ret != SR_OK)
684                 return ret;
685         ret = serial_read_blocking(serial, b, l, 1000);
686         if (ret < 0)
687                 return ret;
688         if ((size_t)ret != l)
689                 return SR_ERR_IO;
690         state->rsp.fill_pos += l;
691
692         /* Devel support: dump the new receive data. */
693         if (sr_log_loglevel_get() >= SR_LOG_SPEW) {
694                 GString *text;
695                 const char *req_text;
696
697                 req_text = (req == REQ_LIVE_READ_520) ? "LIVE" :
698                         (req == REQ_REC_HEAD) ? "MEM HEAD" :
699                         (req == REQ_REC_NEXT) ? "MEM NEXT" :
700                         (req == REQ_REC_CURR) ? "MEM CURR" :
701                         "<inv>";
702                 text = sr_hexdump_new(b, l);
703                 sr_spew("%s: %s", req_text, text->str);
704                 sr_hexdump_free(text);
705         }
706
707         /* Verify checksum. No CURR repetition is attempted here. */
708         if (l > 24) {
709                 uint16_t calc, rcvd;
710
711                 calc = bm52x_rec_checksum(b, 24);
712                 rcvd = read_u16le(&b[24]);
713                 if (calc != rcvd)
714                         return SR_ERR_DATA;
715                 state->rsp.fill_pos -= 32 - 24;
716         }
717
718         /* Seed amount of total available data from HEAD response. */
719         if (req == REQ_REC_HEAD) {
720                 const uint8_t *rdptr;
721
722                 rdptr = &state->rsp.buff[0];
723                 (void)read_u8_inc(&rdptr); /* model ID */
724                 state->rsp.remain = read_u24le_inc(&rdptr); /* byte count */
725         }
726
727         return SR_OK;
728 }
729
730 /** Make sure a minimum amount of response data is available. */
731 static const uint8_t *bm52x_rec_ensure(struct sr_serial_dev_inst *serial,
732         size_t min_count, struct brymen_bm52x_state *state)
733 {
734         size_t got;
735         const uint8_t *read_ptr;
736         int ret;
737
738         got = state->rsp.fill_pos - state->rsp.read_pos;
739         if (got >= min_count) {
740                 read_ptr = &state->rsp.buff[state->rsp.read_pos];
741                 return read_ptr;
742         }
743         ret = bm52x_rec_next_rsp(serial, REQ_REC_NEXT, state);
744         if (ret < 0)
745                 return NULL;
746         read_ptr = &state->rsp.buff[state->rsp.read_pos];
747         return read_ptr;
748 }
749
750 /** Get a u8 quantity of response data, with auto-fetch and position increment. */
751 static uint8_t bm52x_rec_get_u8(struct sr_serial_dev_inst *serial,
752         struct brymen_bm52x_state *state)
753 {
754         const uint8_t *read_ptr;
755         uint8_t value;
756         size_t length;
757
758         length = sizeof(value);
759         if (length > state->rsp.remain) {
760                 state->rsp.remain = 0;
761                 return 0;
762         }
763         read_ptr = bm52x_rec_ensure(serial, length, state);
764         if (!read_ptr)
765                 return 0;
766         value = read_u8(read_ptr);
767         state->rsp.read_pos += length;
768         state->rsp.remain -= length;
769         return value;
770 }
771
772 /** Get a u16 quantity of response data, with auto-fetch and position increment. */
773 static uint16_t bm52x_rec_get_u16(struct sr_serial_dev_inst *serial,
774         struct brymen_bm52x_state *state)
775 {
776         const uint8_t *read_ptr;
777         uint16_t value;
778         size_t length;
779
780         length = sizeof(value);
781         if (length > state->rsp.remain) {
782                 state->rsp.remain = 0;
783                 return 0;
784         }
785         read_ptr = bm52x_rec_ensure(serial, length, state);
786         if (!read_ptr)
787                 return 0;
788         value = read_u16le(read_ptr);
789         state->rsp.read_pos += length;
790         state->rsp.remain -= length;
791         return value;
792 }
793
794 /** Get a u24 quantity of response data, with auto-fetch and position increment. */
795 static uint32_t bm52x_rec_get_u24(struct sr_serial_dev_inst *serial,
796         struct brymen_bm52x_state *state)
797 {
798         const uint8_t *read_ptr;
799         uint32_t value;
800         size_t length;
801
802         length = 24 / sizeof(uint8_t) / 8;
803         if (length > state->rsp.remain) {
804                 state->rsp.remain = 0;
805                 return 0;
806         }
807         read_ptr = bm52x_rec_ensure(serial, length, state);
808         if (!read_ptr)
809                 return 0;
810         value = read_u24le(read_ptr);
811         state->rsp.read_pos += length;
812         state->rsp.remain -= length;
813         return value;
814 }
815
816 /** Get the HEAD chunk of recording data, determine session page count. */
817 static int bm52x_rec_get_count(struct brymen_bm52x_state *state,
818         struct sr_serial_dev_inst *serial)
819 {
820         int ret;
821         size_t byte_count, sess_count;
822
823         memset(&state->rsp, 0, sizeof(state->rsp));
824         ret = bm52x_rec_next_rsp(serial, REQ_REC_HEAD, state);
825         if (ret != SR_OK)
826                 return ret;
827
828         (void)bm52x_rec_get_u8(serial, state); /* model ID */
829         byte_count = bm52x_rec_get_u24(serial, state); /* total bytes count */
830         sess_count = bm52x_rec_get_u16(serial, state); /* session count */
831         sr_dbg("bytes %zu, sessions %zu", byte_count, sess_count);
832
833         return sess_count;
834 }
835
836 static double bm52x_rec_get_value(uint32_t raw, const int *ranges, int *digits)
837 {
838         uint16_t val_digs;
839         gboolean is_neg, is_ol, low_batt;
840         uint8_t range;
841         double value;
842         int decimals;
843
844         val_digs = raw >> 8;
845         is_neg = raw & (1u << 7);
846         is_ol = raw & (1u << 6);
847         low_batt = raw & (1u << 5);
848         range = raw & 0x0f;
849         sr_dbg("item: %s%u, %s %s, range %01x",
850                 is_neg ? "-" : "+", val_digs,
851                 is_ol ? "OL" : "ol", low_batt ? "BATT" : "batt",
852                 range);
853
854         /* Convert to number. OL takes precedence. */
855         *digits = 0;
856         value = val_digs;
857         if (ranges && ranges[range]) {
858                 decimals = ranges[range];
859                 value /= pow(10, decimals);
860                 *digits = decimals;
861         }
862         if (is_ol)
863                 value = INFINITY;
864         if (is_neg)
865                 value *= -1;
866
867         /*
868          * Implementor's note: "Low battery" conditions are worth a
869          * warning since the reading could be incorrect. Rate limiting
870          * is not needed since the Brymen DMM will stop recording in
871          * that case, so at most the last sample in the session page
872          * could be affected.
873          */
874         if (low_batt)
875                 sr_warn("Recording was taken when battery was low.");
876
877         return value;
878 }
879
880 static int bm52x_rec_prep_feed(uint8_t bfunc, uint8_t bsel, uint8_t bstat,
881         struct sr_datafeed_analog *analog1, struct sr_datafeed_analog *analog2,
882         double *value1, double *value2, const int **ranges1, const int **ranges2,
883         const struct sr_dev_inst *sdi)
884 {
885         struct sr_channel *ch;
886         gboolean is_amp, is_deg_f;
887         enum sr_mq *mq1, *mq2;
888         enum sr_unit *unit1, *unit2;
889         enum sr_mqflag *mqf1, *mqf2;
890         enum sr_unit unit_c_f;
891         const int *r_a_ma;
892
893         /* Prepare general submission on first channel. */
894         analog1->data = value1;
895         analog1->encoding->unitsize = sizeof(*value1);
896         analog1->num_samples = 1;
897         ch = g_slist_nth_data(sdi->channels, 0);
898         analog1->meaning->channels = g_slist_append(NULL, ch);
899         *ranges1 = NULL;
900         mq1 = &analog1->meaning->mq;
901         mqf1 = &analog1->meaning->mqflags;
902         unit1 = &analog1->meaning->unit;
903
904         /* Prepare general submission on second channel. */
905         analog2->data = value2;
906         analog2->encoding->unitsize = sizeof(*value2);
907         analog2->num_samples = 1;
908         ch = g_slist_nth_data(sdi->channels, 1);
909         analog2->meaning->channels = g_slist_append(NULL, ch);
910         *ranges2 = NULL;
911         mq2 = &analog2->meaning->mq;
912         mqf2 = &analog2->meaning->mqflags;
913         unit2 = &analog2->meaning->unit;
914
915         /* Derive main/secondary display functions from bfunc/bsel/bstat. */
916         is_amp = bstat & (1u << 5);
917         is_deg_f = bstat & (1u << 4);
918         switch (bfunc) {
919         case 1: /* AC V */
920                 switch (bsel) {
921                 case 0: /* AC volt, Hz */
922                         *ranges1 = bm52x_ranges_volt;
923                         *mq1 = SR_MQ_VOLTAGE;
924                         *mqf1 |= SR_MQFLAG_AC;
925                         *unit1 = SR_UNIT_VOLT;
926                         *ranges2 = bm52x_ranges_freq;
927                         *mq2 = SR_MQ_FREQUENCY;
928                         *unit2 = SR_UNIT_HERTZ;
929                         break;
930                 case 1: /* Hz, AC volt */
931                         *ranges1 = bm52x_ranges_freq;
932                         *mq1 = SR_MQ_FREQUENCY;
933                         *unit1 = SR_UNIT_HERTZ;
934                         *ranges2 = bm52x_ranges_volt;
935                         *mq2 = SR_MQ_VOLTAGE;
936                         *mqf2 |= SR_MQFLAG_AC;
937                         *unit2 = SR_UNIT_VOLT;
938                         break;
939                 default:
940                         return SR_ERR_DATA;
941                 }
942                 break;
943         case 2: /* DC V */
944                 switch (bsel) {
945                 case 0: /* DC V, - */
946                         *ranges1 = bm52x_ranges_volt;
947                         *mq1 = SR_MQ_VOLTAGE;
948                         *mqf1 |= SR_MQFLAG_DC;
949                         *unit1 = SR_UNIT_VOLT;
950                         break;
951                 case 1: /* DC V, AC V */
952                         *ranges1 = bm52x_ranges_volt;
953                         *mq1 = SR_MQ_VOLTAGE;
954                         *mqf1 |= SR_MQFLAG_DC;
955                         *unit1 = SR_UNIT_VOLT;
956                         *ranges2 = bm52x_ranges_volt;
957                         *mq2 = SR_MQ_VOLTAGE;
958                         *mqf2 |= SR_MQFLAG_AC;
959                         *unit2 = SR_UNIT_VOLT;
960                         break;
961                 case 2: /* DC+AC V, AC V */
962                         *ranges1 = bm52x_ranges_volt;
963                         *mq1 = SR_MQ_VOLTAGE;
964                         *mqf1 |= SR_MQFLAG_DC;
965                         *mqf1 |= SR_MQFLAG_AC;
966                         *unit1 = SR_UNIT_VOLT;
967                         *ranges2 = bm52x_ranges_volt;
968                         *mq2 = SR_MQ_VOLTAGE;
969                         *mqf2 |= SR_MQFLAG_AC;
970                         *unit2 = SR_UNIT_VOLT;
971                         break;
972                 default:
973                         return SR_ERR_DATA;
974                 }
975                 break;
976         case 3: /* DC mV */
977                 switch (bsel) {
978                 case 0: /* DC mV, - */
979                         *ranges1 = bm52x_ranges_millivolt;
980                         *mq1 = SR_MQ_VOLTAGE;
981                         *mqf1 |= SR_MQFLAG_DC;
982                         *unit1 = SR_UNIT_VOLT;
983                         break;
984                 case 1: /* DC mV, AC mV */
985                         *ranges1 = bm52x_ranges_millivolt;
986                         *mq1 = SR_MQ_VOLTAGE;
987                         *mqf1 |= SR_MQFLAG_DC;
988                         *unit1 = SR_UNIT_VOLT;
989                         *ranges2 = bm52x_ranges_millivolt;
990                         *mq2 = SR_MQ_VOLTAGE;
991                         *mqf2 |= SR_MQFLAG_AC;
992                         *unit2 = SR_UNIT_VOLT;
993                         break;
994                 case 2: /* DC+AC mV, AC mV */
995                         *ranges1 = bm52x_ranges_millivolt;
996                         *mq1 = SR_MQ_VOLTAGE;
997                         *mqf1 |= SR_MQFLAG_DC;
998                         *mqf1 |= SR_MQFLAG_AC;
999                         *unit1 = SR_UNIT_VOLT;
1000                         *ranges2 = bm52x_ranges_millivolt;
1001                         *mq2 = SR_MQ_VOLTAGE;
1002                         *mqf2 |= SR_MQFLAG_AC;
1003                         *unit2 = SR_UNIT_VOLT;
1004                         break;
1005                 case 3: /* Hz, - */
1006                         *ranges1 = bm52x_ranges_freq;
1007                         *mq1 = SR_MQ_FREQUENCY;
1008                         *unit1 = SR_UNIT_HERTZ;
1009                         break;
1010                 case 4: /* %, - */
1011                         *ranges1 = bm52x_ranges_duty;
1012                         *mq1 = SR_MQ_DUTY_CYCLE;
1013                         *unit1 = SR_UNIT_PERCENTAGE;
1014                         break;
1015                 default:
1016                         return SR_ERR_DATA;
1017                 }
1018                 break;
1019         case 4: /* AC mV */
1020                 switch (bsel) {
1021                 case 0: /* AC mV, Hz */
1022                         *ranges1 = bm52x_ranges_millivolt;
1023                         *mq1 = SR_MQ_VOLTAGE;
1024                         *mqf1 |= SR_MQFLAG_AC;
1025                         *unit1 = SR_UNIT_VOLT;
1026                         *ranges2 = bm52x_ranges_freq;
1027                         *mq2 = SR_MQ_FREQUENCY;
1028                         *unit2 = SR_UNIT_HERTZ;
1029                         break;
1030                 case 1: /* Hz, AC mV */
1031                         *ranges1 = bm52x_ranges_freq;
1032                         *mq1 = SR_MQ_FREQUENCY;
1033                         *unit1 = SR_UNIT_HERTZ;
1034                         *ranges2 = bm52x_ranges_millivolt;
1035                         *mq2 = SR_MQ_VOLTAGE;
1036                         *mqf2 |= SR_MQFLAG_AC;
1037                         *unit2 = SR_UNIT_VOLT;
1038                         break;
1039                 default:
1040                         return SR_ERR_DATA;
1041                 }
1042                 break;
1043         case 5: /* Res/Cond/Cont */
1044                 switch (bsel) {
1045                 case 0: /* Resistance */
1046                         *ranges1 = bm52x_ranges_ohm;
1047                         *mq1 = SR_MQ_RESISTANCE;
1048                         *unit1 = SR_UNIT_OHM;
1049                         break;
1050                 case 1: /* Siemens */
1051                         *ranges1 = bm52x_ranges_cond;
1052                         *mq1 = SR_MQ_CONDUCTANCE;
1053                         *unit1 = SR_UNIT_SIEMENS;
1054                         break;
1055                 case 2: /* Continuity */
1056                         *ranges1 = bm52x_ranges_ohm;
1057                         *mq1 = SR_MQ_CONTINUITY;
1058                         *unit1 = SR_UNIT_OHM;
1059                         break;
1060                 default:
1061                         return SR_ERR_DATA;
1062                 }
1063                 break;
1064         case 6: /* Temperature */
1065                 unit_c_f = is_deg_f ? SR_UNIT_FAHRENHEIT : SR_UNIT_CELSIUS;
1066                 switch (bsel) {
1067                 case 0: /* T1, - */
1068                         *ranges1 = bm52x_ranges_temp;
1069                         *mq1 = SR_MQ_TEMPERATURE;
1070                         *unit1 = unit_c_f;
1071                         break;
1072                 case 1: /* T2, - */
1073                         *ranges1 = bm52x_ranges_temp;
1074                         *mq1 = SR_MQ_TEMPERATURE;
1075                         *unit1 = unit_c_f;
1076                         break;
1077                 case 2: /* T1, T2 */
1078                         *ranges1 = bm52x_ranges_temp;
1079                         *mq1 = SR_MQ_TEMPERATURE;
1080                         *unit1 = unit_c_f;
1081                         *ranges2 = bm52x_ranges_temp;
1082                         *mq2 = SR_MQ_TEMPERATURE;
1083                         *unit2 = unit_c_f;
1084                         break;
1085                 case 3: /* T1-T2, T2 */
1086                         *ranges1 = bm52x_ranges_temp;
1087                         *mq1 = SR_MQ_TEMPERATURE;
1088                         *unit1 = unit_c_f;
1089                         *ranges2 = bm52x_ranges_temp;
1090                         *mq2 = SR_MQ_TEMPERATURE;
1091                         *unit2 = unit_c_f;
1092                         break;
1093                 default:
1094                         return SR_ERR_DATA;
1095                 }
1096                 break;
1097         case 7: /* Cap/Diode */
1098                 switch (bsel) {
1099                 case 0: /* Capacitance, - */
1100                         *ranges1 = bm52x_ranges_cap;
1101                         *mq1 = SR_MQ_CAPACITANCE;
1102                         *unit1 |= SR_UNIT_FARAD;
1103                         break;
1104                 case 1: /* Diode voltage, - */
1105                         *ranges1 = bm52x_ranges_diode;
1106                         *mq1 = SR_MQ_VOLTAGE;
1107                         *mqf1 |= SR_MQFLAG_DC;
1108                         *mqf1 |= SR_MQFLAG_DIODE;
1109                         *unit1 |= SR_UNIT_VOLT;
1110                         break;
1111                 default:
1112                         return SR_ERR_DATA;
1113                 }
1114                 break;
1115         case 8: /* DC A/mA */
1116                 r_a_ma = is_amp ? bm52x_ranges_amp : bm52x_ranges_milliamp;
1117                 switch (bsel) {
1118                 case 0: /* DC A/mA, - */
1119                         *ranges1 = r_a_ma;
1120                         *mq1 = SR_MQ_CURRENT;
1121                         *mqf1 |= SR_MQFLAG_DC;
1122                         *unit1 = SR_UNIT_AMPERE;
1123                         break;
1124                 case 1: /* DC A/mA, AC A/mA */
1125                         *ranges1 = r_a_ma;
1126                         *mq1 = SR_MQ_CURRENT;
1127                         *mqf1 |= SR_MQFLAG_DC;
1128                         *unit1 = SR_UNIT_AMPERE;
1129                         *ranges2 = r_a_ma;
1130                         *mq2 = SR_MQ_CURRENT;
1131                         *mqf2 |= SR_MQFLAG_AC;
1132                         *unit2 = SR_UNIT_AMPERE;
1133                         break;
1134                 case 2: /* DC+AC A/mA, AC A/mA */
1135                         *ranges1 = r_a_ma;
1136                         *mq1 = SR_MQ_CURRENT;
1137                         *mqf1 |= SR_MQFLAG_DC;
1138                         *mqf1 |= SR_MQFLAG_AC;
1139                         *unit1 = SR_UNIT_AMPERE;
1140                         *ranges2 = r_a_ma;
1141                         *mq2 = SR_MQ_CURRENT;
1142                         *mqf2 |= SR_MQFLAG_AC;
1143                         *unit2 = SR_UNIT_AMPERE;
1144                         break;
1145                 case 3: /* AC A/mA, Hz */
1146                         *ranges1 = r_a_ma;
1147                         *mq1 = SR_MQ_CURRENT;
1148                         *mqf1 |= SR_MQFLAG_AC;
1149                         *unit1 = SR_UNIT_AMPERE;
1150                         *ranges2 = bm52x_ranges_freq;
1151                         *mq2 = SR_MQ_FREQUENCY;
1152                         *unit2 = SR_UNIT_HERTZ;
1153                         break;
1154                 default:
1155                         return SR_ERR_DATA;
1156                 }
1157                 break;
1158         case 9: /* DC uA */
1159                 switch (bsel) {
1160                 case 0: /* DC uA, - */
1161                         *ranges1 = bm52x_ranges_microamp;
1162                         *mq1 = SR_MQ_CURRENT;
1163                         *mqf1 |= SR_MQFLAG_DC;
1164                         *unit1 = SR_UNIT_AMPERE;
1165                         break;
1166                 case 1: /* DC uA, AC uA */
1167                         *ranges1 = bm52x_ranges_microamp;
1168                         *mq1 = SR_MQ_CURRENT;
1169                         *mqf1 |= SR_MQFLAG_DC;
1170                         *unit1 = SR_UNIT_AMPERE;
1171                         *ranges2 = bm52x_ranges_microamp;
1172                         *mq2 = SR_MQ_CURRENT;
1173                         *mqf2 |= SR_MQFLAG_AC;
1174                         *unit2 = SR_UNIT_AMPERE;
1175                         break;
1176                 case 2: /* DC+AC uA, AC uA */
1177                         *ranges1 = bm52x_ranges_microamp;
1178                         *mq1 = SR_MQ_CURRENT;
1179                         *mqf1 |= SR_MQFLAG_DC;
1180                         *mqf1 |= SR_MQFLAG_AC;
1181                         *unit1 = SR_UNIT_AMPERE;
1182                         *ranges2 = bm52x_ranges_microamp;
1183                         *mq2 = SR_MQ_CURRENT;
1184                         *mqf2 |= SR_MQFLAG_AC;
1185                         *unit2 = SR_UNIT_AMPERE;
1186                         break;
1187                 case 3: /* AC uA, Hz */
1188                         *ranges1 = bm52x_ranges_microamp;
1189                         *mq1 = SR_MQ_CURRENT;
1190                         *mqf1 |= SR_MQFLAG_AC;
1191                         *unit1 = SR_UNIT_AMPERE;
1192                         *ranges2 = bm52x_ranges_freq;
1193                         *mq2 = SR_MQ_FREQUENCY;
1194                         *unit2 = SR_UNIT_HERTZ;
1195                         break;
1196                 default:
1197                         return SR_ERR_DATA;
1198                 }
1199                 break;
1200         default:
1201                 return SR_ERR_DATA;
1202         }
1203
1204         return SR_OK;
1205 }
1206
1207 /** Traverse one recorded session page, optionally feed session bus. */
1208 static int bm52x_rec_read_page_int(const struct sr_dev_inst *sdi,
1209         struct brymen_bm52x_state *state, struct sr_serial_dev_inst *serial,
1210         gboolean skip)
1211 {
1212         uint8_t bfunc, bsel, bstat;
1213         uint8_t ival;
1214         gboolean has_sec_disp;
1215         size_t page_len, meas_len, meas_count;
1216         uint32_t meas_data;
1217         struct sr_datafeed_packet packet;
1218         struct sr_datafeed_analog analog1, analog2;
1219         struct sr_analog_encoding encoding1, encoding2;
1220         struct sr_analog_meaning meaning1, meaning2;
1221         struct sr_analog_spec spec1, spec2;
1222         int digits, ret;
1223         double values[2];
1224         const int *ranges1, *ranges2;
1225         enum sr_configkey key;
1226         uint64_t num;
1227
1228         sr_dbg("progress: %s, %s", __func__, skip ? "skip" : "feed");
1229
1230         /* Get the header information of the session page (raw). */
1231         if (bm52x_rec_get_u8(serial, state) != 0xee) /* "DLE" */
1232                 return SR_ERR_DATA;
1233         if (bm52x_rec_get_u8(serial, state) != 0xa0) /* "STX" */
1234                 return SR_ERR_DATA;
1235         (void)bm52x_rec_get_u24(serial, state); /* prev page addr */
1236         (void)bm52x_rec_get_u24(serial, state); /* next page addr */
1237         bfunc = bm52x_rec_get_u8(serial, state); /* meter function */
1238         bsel = bm52x_rec_get_u8(serial, state); /* fun selection */
1239         bstat = bm52x_rec_get_u8(serial, state); /* status */
1240         page_len = bm52x_rec_get_u24(serial, state); /* page length */
1241         sr_dbg("page head: func/sel/state %02x/%02x/%02x, len %zu",
1242                 bfunc, bsel, bstat, page_len);
1243
1244         /* Interpret the header information of the session page. */
1245         ival = bstat & 0x0f;
1246         has_sec_disp = bstat & (1u << 7);
1247         meas_len = (has_sec_disp ? 2 : 1) * 3;
1248         if (page_len % meas_len)
1249                 return SR_ERR_DATA;
1250         meas_count = page_len / meas_len;
1251         sr_dbg("page head: ival %u, %s, samples %zu",
1252                 ival, has_sec_disp ? "dual" : "main", meas_count);
1253
1254         /* Prepare feed to the sigrok session. Send rate/interval. */
1255         sr_analog_init(&analog1, &encoding1, &meaning1, &spec1, 0);
1256         sr_analog_init(&analog2, &encoding2, &meaning2, &spec2, 0);
1257         ret = bm52x_rec_prep_feed(bfunc, bsel, bstat,
1258                 &analog1, &analog2, &values[0], &values[1],
1259                 &ranges1, &ranges2, sdi);
1260         if (ret != SR_OK)
1261                 return SR_ERR_DATA;
1262         if (!skip) {
1263                 memset(&packet, 0, sizeof(packet));
1264                 packet.type = SR_DF_ANALOG;
1265
1266                 if (bm52x_rec_ivals[ival].freq_rate) {
1267                         sr_dbg("rate: %u", bm52x_rec_ivals[ival].freq_rate);
1268                         key = SR_CONF_SAMPLERATE;
1269                         num = bm52x_rec_ivals[ival].freq_rate;
1270                         (void)sr_session_send_meta(sdi,
1271                                 key, g_variant_new_uint64(num));
1272                 }
1273                 if (bm52x_rec_ivals[ival].ival_secs) {
1274                         sr_dbg("ival: %u", bm52x_rec_ivals[ival].ival_secs);
1275                         key = SR_CONF_SAMPLE_INTERVAL;
1276                         num = bm52x_rec_ivals[ival].ival_secs * 1000; /* in ms */
1277                         (void)sr_session_send_meta(sdi,
1278                                 key, g_variant_new_uint64(num));
1279                 }
1280         }
1281
1282         /*
1283          * Implementor's note:
1284          * Software limits require devc access, which is an internal
1285          * detail of the serial-dmm driver, which this bm52x parser
1286          * is not aware of. So we always provide the complete set of
1287          * recorded samples. Should be acceptable. Duplicating limit
1288          * support in local config get/set is considered undesirable.
1289          */
1290         while (meas_count--) {
1291                 meas_data = bm52x_rec_get_u24(serial, state);
1292                 values[0] = bm52x_rec_get_value(meas_data, ranges1, &digits);
1293                 if (!skip) {
1294                         analog1.encoding->digits  = digits;
1295                         analog1.spec->spec_digits = digits;
1296                         packet.payload = &analog1;
1297                         ret = sr_session_send(sdi, &packet);
1298                         if (ret != SR_OK)
1299                                 return ret;
1300                 }
1301
1302                 if (!has_sec_disp)
1303                         continue;
1304                 meas_data = bm52x_rec_get_u24(serial, state);
1305                 values[1] = bm52x_rec_get_value(meas_data, ranges2, &digits);
1306                 if (!skip) {
1307                         analog2.encoding->digits  = digits;
1308                         analog2.spec->spec_digits = digits;
1309                         packet.payload = &analog2;
1310                         ret = sr_session_send(sdi, &packet);
1311                         if (ret != SR_OK)
1312                                 return ret;
1313                 }
1314         }
1315
1316         /* Check termination of the session page. */
1317         if (bm52x_rec_get_u8(serial, state) != 0xee) /* "DLE" */
1318                 return SR_ERR_DATA;
1319         if (bm52x_rec_get_u8(serial, state) != 0xc0) /* "ETX" */
1320                 return SR_ERR_DATA;
1321
1322         return SR_OK;
1323 }
1324
1325 /** Skip one recorded session page. */
1326 static int bm52x_rec_skip_page(const struct sr_dev_inst *sdi,
1327         struct brymen_bm52x_state *state, struct sr_serial_dev_inst *serial)
1328 {
1329         return bm52x_rec_read_page_int(sdi, state, serial, TRUE);
1330 }
1331
1332 /** Forward one recorded session page. */
1333 static int bm52x_rec_read_page(const struct sr_dev_inst *sdi,
1334         struct brymen_bm52x_state *state, struct sr_serial_dev_inst *serial)
1335 {
1336         return bm52x_rec_read_page_int(sdi, state, serial, FALSE);
1337 }
1338
1339 SR_PRIV void *brymen_bm52x_state_init(void)
1340 {
1341         return g_malloc0(sizeof(struct brymen_bm52x_state));
1342 }
1343
1344 SR_PRIV void brymen_bm52x_state_free(void *state)
1345 {
1346         g_free(state);
1347 }
1348
1349 SR_PRIV int brymen_bm52x_config_get(void *st, uint32_t key, GVariant **data,
1350         const struct sr_dev_inst *sdi, const struct sr_channel_group *cg)
1351 {
1352         struct brymen_bm52x_state *state;
1353         char text[20];
1354
1355         state = st;
1356
1357         if (!sdi)
1358                 return SR_ERR_NA;
1359         (void)cg;
1360
1361         switch (key) {
1362         case SR_CONF_DATA_SOURCE:
1363                 if (!state)
1364                         return SR_ERR_ARG;
1365                 if (state->sess_idx == 0)
1366                         snprintf(text, sizeof(text), "Live");
1367                 else
1368                         snprintf(text, sizeof(text), "Rec-%zu", state->sess_idx);
1369                 *data = g_variant_new_string(text);
1370                 return SR_OK;
1371         default:
1372                 return SR_ERR_NA;
1373         }
1374 }
1375
1376 SR_PRIV int brymen_bm52x_config_set(void *st, uint32_t key, GVariant *data,
1377         const struct sr_dev_inst *sdi, const struct sr_channel_group *cg)
1378 {
1379         struct brymen_bm52x_state *state;
1380         const char *s;
1381         int ret, nr;
1382
1383         state = st;
1384
1385         if (!sdi)
1386                 return SR_ERR_NA;
1387         (void)cg;
1388
1389         switch (key) {
1390         case SR_CONF_DATA_SOURCE:
1391                 s = g_variant_get_string(data, NULL);
1392                 if (!s || !*s)
1393                         return SR_ERR_ARG;
1394                 if (strcasecmp(s, "Live") == 0) {
1395                         state->sess_idx = 0;
1396                         return SR_OK;
1397                 }
1398                 if (strncasecmp(s, "Rec-", strlen("Rec-")) != 0)
1399                         return SR_ERR_ARG;
1400                 s += strlen("Rec-");
1401                 ret = sr_atoi(s, &nr);
1402                 if (ret != SR_OK || nr <= 0 || nr > 999)
1403                         return SR_ERR_ARG;
1404                 state->sess_idx = nr;
1405                 return SR_OK;
1406         default:
1407                 return SR_ERR_NA;
1408         }
1409 }
1410
1411 SR_PRIV int brymen_bm52x_config_list(void *st, uint32_t key, GVariant **data,
1412         const struct sr_dev_inst *sdi, const struct sr_channel_group *cg)
1413 {
1414         struct brymen_bm52x_state *state;
1415         struct sr_serial_dev_inst *serial;
1416         int ret;
1417         size_t count, idx;
1418         GVariantBuilder gvb;
1419         char name[20];
1420
1421         /*
1422          * Have common keys handled by caller's common code.
1423          * ERR N/A results in the caller's logic handling the request.
1424          * Only handle strictly local properties here in this code path.
1425          */
1426         switch (key) {
1427         case SR_CONF_SCAN_OPTIONS:
1428                 /* Scan options. Common property. */
1429                 return SR_ERR_NA;
1430         case SR_CONF_DEVICE_OPTIONS:
1431                 if (!sdi)
1432                         /* Driver options. Common property. */
1433                         return SR_ERR_NA;
1434                 if (cg)
1435                         /* Channel group's devopts. Common error path. */
1436                         return SR_ERR_NA;
1437                 /* List meter's local device options. Overrides common data. */
1438                 *data = g_variant_new_fixed_array(G_VARIANT_TYPE_UINT32,
1439                                 devopts, ARRAY_SIZE(devopts), sizeof(uint32_t));
1440                 return SR_OK;
1441         case SR_CONF_DATA_SOURCE:
1442                 state = st;
1443                 if (!sdi)
1444                         return SR_ERR_ARG;
1445                 serial = sdi->conn;
1446                 ret = bm52x_rec_get_count(state, serial);
1447                 if (ret < 0)
1448                         return ret;
1449                 count = ret;
1450                 g_variant_builder_init(&gvb, G_VARIANT_TYPE_ARRAY);
1451                 for (idx = 0; idx <= count; idx++) {
1452                         if (idx == 0)
1453                                 snprintf(name, sizeof(name), "Live");
1454                         else
1455                                 snprintf(name, sizeof(name), "Rec-%zu", idx);
1456                         g_variant_builder_add(&gvb, "s", name);
1457                 }
1458                 *data = g_variant_builder_end(&gvb);
1459                 return SR_OK;
1460         default:
1461                 return SR_ERR_NA;
1462         }
1463 }
1464
1465 /**
1466  * BM520s specific receive routine for recorded measurements.
1467  *
1468  * @param[in] fd File descriptor.
1469  * @param[in] revents Mask of pending events.
1470  * @param[in] cb_data Call back data (receive handler state).
1471  *
1472  * @return TRUE when the routine needs to get re-invoked, FALSE when the
1473  *   routine is done and no further invocations are required.
1474  *
1475  * @private
1476  *
1477  * It's an implementation detail that a single invocation will carry out
1478  * all the work that is involved in reading back recorded measurements.
1479  */
1480 static int bm52x_rec_receive_data(int fd, int revents, void *cb_data)
1481 {
1482         struct brymen_bm52x_state *state;
1483         const struct sr_dev_inst *sdi;
1484         struct sr_dev_inst *sdi_rw;
1485         struct sr_serial_dev_inst *serial;
1486         int ret;
1487         size_t count, idx;
1488
1489         (void)fd;
1490         (void)revents;
1491         state = cb_data;
1492
1493         sdi = state->sdi;
1494         serial = sdi->conn;
1495
1496         ret = bm52x_rec_get_count(state, serial);
1497         if (ret < 0)
1498                 return FALSE;
1499         count = ret;
1500
1501         /* Un-const 'sdi' since sr_dev_acquisition_stop() needs that. */
1502         sdi_rw = (struct sr_dev_inst *)sdi;
1503
1504         /*
1505          * Immediate (silent, zero data) stop for non-existent sessions.
1506          * Early exit is an arbitrary implementation detail, in theory
1507          * the loop below would transparently handle the situation when
1508          * users request non-existing session pages.
1509          */
1510         if (state->sess_idx > count) {
1511                 sr_dev_acquisition_stop(sdi_rw);
1512                 return FALSE;
1513         }
1514
1515         /* Iterate all session pages, forward the one of interest. */
1516         for (idx = 1; idx <= count; idx++) {
1517                 if (idx == state->sess_idx)
1518                         ret = bm52x_rec_read_page(sdi, state, serial);
1519                 else
1520                         ret = bm52x_rec_skip_page(sdi, state, serial);
1521                 if (ret != SR_OK)
1522                         break;
1523         }
1524
1525         sr_dev_acquisition_stop(sdi_rw);
1526         return FALSE;
1527 }
1528
1529 /**
1530  * BM520s specific acquisition start callback.
1531  *
1532  * @param[in] st DMM parser state.
1533  * @param[in] sdi Device instance.
1534  * @param[out] cb Receive callback for the acquisition.
1535  * @param[out] cb_data Callback data for receive callback.
1536  *
1537  * @returns SR_OK upon success.
1538  * @returns SR_ERR* upon failure.
1539  *
1540  * @private
1541  *
1542  * The BM520s protocol parser uses common logic and the packet parser
1543  * for live acquisition, but runs a different set of requests and a
1544  * different response layout interpretation for recorded measurements.
1545  */
1546 SR_PRIV int brymen_bm52x_acquire_start(void *st, const struct sr_dev_inst *sdi,
1547         sr_receive_data_callback *cb, void **cb_data)
1548 {
1549         struct brymen_bm52x_state *state;
1550
1551         if (!sdi || !st)
1552                 return SR_ERR_ARG;
1553         state = st;
1554
1555         /* Read live measurements. No local override required. */
1556         if (state->sess_idx == 0)
1557                 return SR_OK;
1558
1559         /* Arrange to read back recorded session. */
1560         sr_dbg("session page requested: %zu", state->sess_idx);
1561         state->sdi = sdi;
1562         *cb = bm52x_rec_receive_data;
1563         *cb_data = state;
1564         return SR_OK;
1565 }