]> sigrok.org Git - sigrok-dumps.git/blobdiff - spi/mx25l1605d/README
i2c: some EDID dumps
[sigrok-dumps.git] / spi / mx25l1605d / README
index ade54066241bbe305402c8c56add543342d49a83..83a987fe746b30879feedaa8d4492b3fe04baa07 100644 (file)
@@ -31,7 +31,6 @@ The ChronoVu LA8 probes were connected to the MX25L1605D chip like this:
   3 (red)     SI/SIO0 (a.k.a MOSI)
   4 (gray)    WP#/ACC
   5 (brown)   HOLD#
-  GND         GND
 
 
 Probing
@@ -46,7 +45,7 @@ The sigrok command line used was:
   sigrok-cli -d 0:samplerate=25mhz --samples 8388608 \
              -p '1=CS#,2=MISO,3=SCLK,4=MOSI,5=WP#,6=HOLD#' \
              --wait-trigger --triggers 3=1 \
-             -o mx25l1605d_probe.sigrok
+             -o mx25l1605d_probe.sr
 
 The capturing starts when the SCLK signal is high for the first time
 (it's low per default). We capture as many samples as fit into the 8MByte
@@ -69,7 +68,7 @@ The sigrok command line used was:
 
   sigrok-cli -d 0:samplerate=25mhz --samples 8388608 \
              -p '1=CS#,2=MISO,3=SCLK,4=MOSI,5=WP#,6=HOLD#' \
-             -o mx25l1605d_write_hello_world.sigrok
+             -o mx25l1605d_write.sr
 
 The capture is only partial, it contains a small part of the write process
 (it does not contain the chip identification, chip erase, etc. which comes
@@ -88,7 +87,7 @@ The sigrok command line used was:
 
   sigrok-cli -d 0:samplerate=25mhz --samples 8388608 \
              -p '1=CS#,2=MISO,3=SCLK,4=MOSI,5=WP#,6=HOLD#' \
-             -o mx25l1605d_read.sigrok
+             -o mx25l1605d_read.sr
 
 The capture only contains a small part of the read procedure. The data in
 the chip consists of consecutive "HelloWorld" ASCII strings.
@@ -105,7 +104,7 @@ The sigrok command line used was:
 
   sigrok-cli -d 0:samplerate=25mhz --samples 8388608 \
              -p '1=CS#,2=MISO,3=SCLK,4=MOSI,5=WP#,6=HOLD#' \
-             -o mx25l1605d_erase.sigrok
+             -o mx25l1605d_erase.sr
 
 The capture does not contain the full erase process, only a small part of it.