2 | Agilent MSO7034A | |
3 | ------------------------------------------------------------------------------- | |
4 | ||
5 | This is a set of files saved/exported from the Agilent MSO7034A oscilloscope. | |
6 | ||
7 | Details: | |
8 | http://www.keysight.com/en/pd-1293631-pn-MSO7034A/mixed-signal-oscilloscope-350-mhz-4-analog-plus-16-digital-channels | |
9 | ||
10 | ||
11 | Setup | |
12 | ----- | |
13 | ||
14 | The oscilloscope has the following options in the 'Save/Recall' menu, that | |
15 | can be used to save the acquired/displayed data on a USB thumb drive: | |
16 | ||
17 | - Trace and Setup | |
18 | - Used to store the data *in* the scope (not on USB thumb drive) | |
19 | - BMP (8-bit) image file | |
20 | - Options: Setup info = y/n, Invert Grat = y/n, Palette = Color/Grayscale | |
21 | - BMP (24-bit) image file | |
22 | - Options: Setup info = y/n, Invert Grat = y/n, Palette = Color/Grayscale | |
23 | - PNG (24-bit) image file | |
24 | - Options: Setup info = y/n, Invert Grat = y/n, Palette = Color/Grayscale | |
25 | - CSV data file | |
26 | - Options: Setup info = y/n, Length = 100/250/500/1000 | |
27 | - ASCII XY data file | |
28 | - Options: Setup info = y/n, Length = x | |
29 | (x = 100/250/500/1000/2000/5000/10000/20000/50000/100000/200000/500000 | |
30 | 1000000/2000000) | |
31 | - ALB data file | |
32 | - Options: Setup info = y/n, Length = x (see above), | |
33 | Alb serial format = Default/CAN/I2C/LIN/UART|RS232/SPI2/SPI3/SPI4 | |
34 | - BIN data file | |
35 | - Options: Setup info = y/n, Length = x (see above) | |
36 | - Lister data file | |
37 | - No options | |
38 | ||
39 | When "Setup info" is enabled, the scope also saves an additional file | |
40 | with the respective basename and a *.txt extention (e.g. "scope_0.txt"), | |
41 | which contains some ASCII info about the scope setup, any measurements | |
42 | displayed on the LCD, and so on. | |
43 | ||
44 | ||
45 | Files | |
46 | ----- | |
47 | ||
48 | Channels 1 and 2 of the (4-channel) scope were connected to the test output | |
49 | of the scope (used for probe impedance matching), which outputs a 1.2kHz | |
50 | square wave signal with an amplitude of 2.5V (2.72V peak-to-peak). | |
51 | ||
52 | After the "Stop" button was pressed, the following files were saved: | |
53 | ||
54 | scope_0: BMP (8-bit) | |
55 | scope_1: BMP (24-bit) | |
56 | scope_2: PNG (24-bit) | |
57 | scope_3: CSV, 1000 | |
58 | scope_4: CSV, 500 | |
59 | scope_5: CSV, 250 | |
60 | scope_6: CSV, 100 | |
61 | scope_7: ASCII XY, 100 | |
62 | scope_8: ASCII XY, 250 | |
63 | ... | |
64 | scope_19: ASCII XY, 1000000 | |
65 | scope_20: ASCII XY, 2000000 | |
66 | scope_21: ALB, 100, Default | |
67 | scope_22: ALB, 100, CAN | |
68 | scope_23: ALB, 100, I2C | |
69 | scope_24: ALB, 100, LIN | |
70 | scope_25: ALB, 100, UART/RS232 | |
71 | scope_26: ALB, 100, SPI2 (SPI3/4 cannot be be used with only 2 channels) | |
72 | scope_27: BIN, 100 | |
73 | scope_28: BIN, 250 | |
74 | scope_29: BIN, 500 | |
75 | scope_30: Lister | |
76 | ||
77 | Only two "Setup info" files are included, scope_0.txt and scope_4.txt. | |
78 | The first one is valid (and identical) for files scope_0* to scope_3*, the | |
79 | latter is valid (and identical) for the files scope_4* to scope_30*. | |
80 | ||