Manson HCS-3xxx series

From sigrok
Revision as of 12:31, 26 June 2014 by Matthias Heidbrink (talk | contribs) (Added commands, etc.)
Jump to navigation Jump to search
Manson HCS-3xxx
Manson hcs3202.png
Status supported
Source code manson-hcs-3xxx
Channels 1
Voltage/current (CH1) various
Connectivity USB
Features programmable presets, cycling functionality
Website manson.com.hk

The Manson HCS-3xxx series are 1 channel switch-mode programmable power supplies with USB/serial connectivity.

Devices

Manson Conrad OEM Peaktech OEM Voltage Range Current Range Power Remarks
HCS-3100 PPS-11810 1-18 V 0-10 A 180 W
HCS-3102 PPS-11360 1-36 V 0-5 A 180 W
HCS-3104 PPS-11603 1-60 V 0-2.5 A 150 W
HCS-3150 - 1-18 V 0-15 A 270 W
HCS-3200 PPS-13610 1-18 V 0-20 A 360 W
HCS-3202 PPS-16005 1-36 V 0-10 A 360 W
HCS-3204 PPS-11815 1-60 V 0-5 A 300 W
HCS-3300-USB - - 1-16 V 0-30 A 480 W
HCS-3302-USB - - 1-32 V 0-15 A 480 W
HCS-3304-USB - - 1-60 V 0-8 A 480 W
HCS-3400-USB - PeakTech 1565 1-16 V 0-40 A 600 W
HCS-3402-USB - PeakTech 1575 1-32 V 0-20 A 600 W?
HCS-3404-USB - - 1-60 V 0-10 A 600 W
HCS-3600-USB - PeakTech 1580 1-16 V 0-60 A 750 W
HCS-3602-USB - PeakTech 1580 1-30 V 0-30 A 900 W
HCS-3604-USB - - 1-60 V 0-15 A 900 W

The devices linked above are supported. The other devices might work, but are untested. If you have one of the unsupported devices and can test it, please contact Matthias.

Some other device series by the same manufacturer exist that use a different communication protocol.

Commands

Implementation in progress!

Function Target Parameters Comment
SR_CONF_OUTPUT_ENABLED Channel Boolean on/off Get: Query output status. Set: Switch output on or off. Power-on default is on.
SR_CONF_OUTPUT_VOLTAGE Channel Double Get: Query output voltage. Updated only if sampling is active!
SR_CONF_OUTPUT_VOLTAGE_MAX Channel Double List: Get 3-tupel (min, max, step) for output voltage range. Get: Get output voltage limit. Set: Set output voltage limit.
SR_CONF_OUTPUT_CURRENT Channel Double Get: Query output current. Updated only if sampling is active!
SR_CONF_OUTPUT_CURRENT_MAX Channel Double List: Get 3-tupel (min, max, step) for output current range. Get: Get output current limit. Set: Set output current limit.

Protocol

ASCII based over USB-to-serial.

Some versions of the protocol description in manuals are incomplete or even erroneous.

Command Reply Description Remarks
GMOD\r 3204\r
OK\r
Query model Four-digit model code, e.g. 3202 for HCS-3202.
GETD\r VVVVCCCCS\r
OK\r
Query displayed voltage, current and mode. Four-digit voltage, e.g. 12.34; four-digit current, e.g. 12.34; status 0=constant voltage, 1=constant current.
SOUT<0|1>\r OK\r Disable output Output on=0 (power-on default), off=1
SESS\r OK\r Disable keyboard Seems to time out after about 5 seconds.
ENDS\r OK\r Enable keyboard (when disabled with SESS).
... ... ... Protocol description incomplete so far.