The Manson HCS-3xxx series are 1 channel switch-mode programmable power supplies with USB/serial connectivity.

Devices

Manson Conrad OEM Peaktech OEM Voltage Range Current Range Power Remarks
HCS-3100 PPS-11810 1-18 V 0-10 A 180 W
HCS-3102 PPS-11360 1-36 V 0-5 A 180 W
HCS-3104 PPS-11603 1-60 V 0-2.5 A 150 W
HCS-3150 - 1-18 V 0-15 A 270 W
HCS-3200 PPS-13610 1-18 V 0-20 A 360 W
HCS-3202 PPS-16005 1-36 V 0-10 A 360 W
HCS-3204 PPS-11815 1-60 V 0-5 A 300 W
HCS-3300-USB - - 1-16 V 0-30 A 480 W
HCS-3302-USB - - 1-32 V 0-15 A 480 W
HCS-3304-USB - - 1-60 V 0-8 A 480 W
HCS-3400-USB - PeakTech 1565 1-16 V 0-40 A 600 W
HCS-3402-USB - PeakTech 1575 1-32 V 0-20 A 600 W?
HCS-3404-USB - - 1-60 V 0-10 A 600 W
HCS-3600-USB - PeakTech 1580 1-16 V 0-60 A 750 W
HCS-3602-USB - PeakTech 1580 1-30 V 0-30 A 900 W
HCS-3604-USB - - 1-60 V 0-15 A 900 W

Some other device series by the same manufacturer exist that use a different communication protocol.

Protocol

ASCII based over USB-to-serial.

Some versions of the protocol description in the manual are incomplete, e.g. do not include the commend to query the model code.

Command Reply Description Remarks
GMOD\r 3204\r
OK\r
Query model Four-digit number, e.g. 3202.
GETD\r VVVVCCCCS\r
OK\r
Query displayed voltage, current and mode. Four-digit voltage, e.g. 12.34; four-digit current, e.g. 12.34; status 0=constant voltage, 1=constant current.
SOUT<0|1>\r OK\r Disable output Output on=0 (power-on default), off=1
SESS\r OK\r Disable keyboard Seems to time out after about 5 seconds.
ENDS\r OK\r Enable keyboard (when disabled with SESS).
... ... ... Protocol description incomplete so far.

Resources