Difference between revisions of "Gossen Metrawatt"

From sigrok
Jump to navigation Jump to search
m (→‎Metrahit 1x series: Added link for Metrahit 14A)
 
(71 intermediate revisions by 2 users not shown)
Line 3: Line 3:
This article tries to give an overview of the multimeters with interfaces for data exchange, OEM models and communication.
This article tries to give an overview of the multimeters with interfaces for data exchange, OEM models and communication.


= Company =
== Company ==
* http://www.gossenmetrawatt.com/ (Homepage)
* http://www.gossenmetrawatt.com/ (Homepage)
* https://de.wikipedia.org/wiki/Gossen_Metrawatt
* https://de.wikipedia.org/wiki/Gossen_Metrawatt


= Multimeters =
== Multimeters ==
One remark concerning device names: The manufacturer writes the name of the device series sometimes "METRAHit", sometimes ''METRAHIT'' or even ''METRA HIT'', sometimes not even consistently for the same device. For simplicity it will be "Metrahit" here most of the time, other names alike.
One remark concerning device names: The manufacturer writes the name of the device series sometimes "METRAHit", sometimes ''METRAHIT'' or even ''METRA HIT'', sometimes not even consistently for the same device. For simplicity it will be "Metrahit" here most of the time, other names alike.


== Metrahit 1x series ==
=== Metrahit 1x series ===


{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable"
{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable"
Line 17: Line 17:
! Siemens OEM
! Siemens OEM
! Rishabh
! Rishabh
! HT OEM
! Count
! Count
! TRMS
! TRMS
Line 25: Line 26:
| Metrahit 12S (GTM 2012 000 R0003)
| Metrahit 12S (GTM 2012 000 R0003)
|
|
| Rish multi 12S
| Rishmulti 12S
|
| style="text-align:right" | 3100
| style="text-align:right" | 3100
| style="text-align:center" |  
| style="text-align:center" | -
| style="text-align:center" |  
| style="text-align:center" |
|
|


Line 34: Line 36:
| Metrahit 13S (GTM 2013 000 R0003)
| Metrahit 13S (GTM 2013 000 R0003)
|
|
| Rish multi 13S
| Rishmulti 13S
|
| style="text-align:right" | 3100
| style="text-align:right" | 3100
| style="text-align:center" |  
| style="text-align:center" | -
| style="text-align:center" |  
| style="text-align:center" |
|
|


Line 43: Line 46:
| [[Gossen Metrawatt Metrahit 14A|Metrahit 14A (GTM 2014 000 R0007)]]
| [[Gossen Metrawatt Metrahit 14A|Metrahit 14A (GTM 2014 000 R0007)]]
| B1102 7KB1102-8AA
| B1102 7KB1102-8AA
|
|
|
| style="text-align:right" | 3100
| style="text-align:right" | 3100
| style="text-align:center" |  
| style="text-align:center" | -
| style="text-align:center" |  
| style="text-align:center" |
|
|


Line 53: Line 57:
| B1103 7KB1103-8AA
| B1103 7KB1103-8AA
| Rishmulti 14S
| Rishmulti 14S
|
| style="text-align:right" | 3100
| style="text-align:right" | 3100
| style="text-align:center" |  
| style="text-align:center" | -
| style="text-align:center" |  
| style="text-align:center" | ●
| Tested successfully by a sigrok user.
 
|-
| Metrahit ONE PLUS (M204D) [https://www.gossenmetrawatt.com/english/produkte/metrahitoneplus.htm]
|
|  
|
|
| style="text-align:right" | 3100
| style="text-align:center" | -
| style="text-align:center" | ●
| Seems to be the successor of the 14S, detected as 14S. Tested successfully by a sigrok user.


|-
|-
Line 62: Line 77:
|
|
| Rishmulti 15S  
| Rishmulti 15S  
| [[HT Instruments HT410]]
| style="text-align:right" | 3100
| style="text-align:right" | 3100
| style="text-align:center" |  
| style="text-align:center" | -
| style="text-align:center" |  
| style="text-align:center" |
|
|


Line 71: Line 87:
| B1104 7KB1104-8AA
| B1104 7KB1104-8AA
| Rishmulti 16S
| Rishmulti 16S
|
| style="text-align:right" | 3100
| style="text-align:right" | 3100
| style="text-align:center" |
| style="text-align:center" | ●
| style="text-align:center" |  
| style="text-align:center" |
|
|


Line 79: Line 96:
| [[Gossen Metrawatt Metrahit 16I|Metrahit 16I (M216B)]]
| [[Gossen Metrawatt Metrahit 16I|Metrahit 16I (M216B)]]
|  
|  
|
|
|
| style="text-align:right" | 3100
| style="text-align:right" | 3100
Line 86: Line 104:


|-
|-
| Metrahit 16L  
| Metrahit 16L (M216L)
|  
|  
|
|
|
| style="text-align:right" | 3100
| style="text-align:right" | 3100
| style="text-align:center" |  ●
| style="text-align:center" |  ●
| style="text-align:center" |  
| style="text-align:center" |
| Seems to be a Metrahit 16I with additional duty cycle function
| Seems to be a Metrahit 16I with additional duty cycle function


Line 97: Line 116:
| Metrahit 16T (M216A)
| Metrahit 16T (M216A)
|  
|  
|
|
|
| style="text-align:right" | 3100
| style="text-align:right" | 3100
| style="text-align:center" |
| style="text-align:center" | ●
| style="text-align:center" |  
| style="text-align:center" |
| Multimeter and insulation tester 100 V telecom; seems to be almost identical to [[Gossen Metrawatt T-Com KMM2002|T-Com KMM2002]].
 
|-
| [[Gossen Metrawatt T-Com KMM2002|T-Com KMM2002 (M216T)]]
|
|
|
| style="text-align:right" | 3100
| style="text-align:center" | ●
| style="text-align:center" | ●
| Multimeter and insulation tester 100 V telecom
| Multimeter and insulation tester 100 V telecom


Line 106: Line 136:
| Metrahit 16U (M216U)  
| Metrahit 16U (M216U)  
|  
|  
|
|
|
| style="text-align:right" | 3100
| style="text-align:right" | 3100
| style="text-align:center" | ?
| style="text-align:center" |
| style="text-align:center" |  
| style="text-align:center" |
| Multimeter and insulation tester for symmetrical copper wire, very similar to 16T
| Multimeter and insulation tester for symmetrical copper wire, very similar to 16T


|-
|-
| Metrahit 17
| [[Gossen Metrawatt Metrahit 18C|Metrahit 18C]]
| B1107 7KB1107-8AA ?
|
|  
|
|
| style="text-align:right" | 3100?
|  
| style="text-align:center" |  
|  
| style="text-align:center" | -
| style="text-align:center" | -
| Milliohm meter (no IR interface, just listed for completeness)
| Calibrator; This device is a signal generator, not a multimeter, and seems to have not much in common with the multimeters except the case. Added here just for completeness.


|-
|-
Line 125: Line 157:
| B1108 7KB1108-8AA
| B1108 7KB1108-8AA
| Rishmulti 18S
| Rishmulti 18S
|
| style="text-align:right" | 31000
| style="text-align:right" | 31000
| style="text-align:center" | ●
| style="text-align:center" | ●
| style="text-align:center" | ●
| style="text-align:center" | ●
|
|


|}
|}


The Metrahit 1x series supports sending data via IR/RS232.  
These multimeter can send data unidirectionally via IR/RS232 (''Send Mode''). It seems that the 3100 count types are actually 31000 count types that do not display the last digit, but can deliver it via the serial interface.


It seems that the 3100 count types are actually 31000 count types that do not display the last digit, but can deliver it via the serial interface.
Currently the ''Metrahit 14A'', ''14S'', ''ONE Plus'', ''15S (HT410)'', ''16I'', ''KMM2002'' and ''18S'' are supported by ''sigrok'' using the driver ''gmc-mh-1x-2x-rs232''.  


The devices are not available from Gossen Metrawatt any more, but it seems that a company in India named [http://rishabh.co.in/ Rishab] in India makes slightly redesigned versions of them.
The models marked with ○ in the ''Supported'' row are untested, but expected to work. See section [[#Metrahit_1x.2F2x_Send_Mode | Metrahit 1x/2x Send Mode]] for details.  


Currently the ''Metrahit 16I'' and ''18S'' with interface [[Gossen_Metrawatt#Metrahit_RS232|RS232]] are supported by ''sigrok'' using the driver ''gmc-mh-1x-2x-rs232''. The other devices (except the ''17'', of course) will work probably, but are untested. Please contact [[User:Matthias_Heidbrink|Matthias]] if you have one of these devices and can test it.
Please contact [[User:Matthias_Heidbrink|Matthias]] if you have one of the unsupported devices and can test it.


== Metrahit 2x Series ==
The devices are not available from Gossen Metrawatt any more, but it seems that a company in India named [http://rishabh.co.in/ Rishabh] makes slightly redesigned versions of some models. The [[HT Instruments HT410]] seems to be another OEM model, probably made by Rishabh.
 
The Metrahit 1x series includes some more devices (''Metrahit 15'' and ''16'' without letter, Milliohm Meter ''Metrahit 17'', some sold as ancestor brand ''ABB Metrawatt'') that are unsupported because they do not have an IR interface.
 
=== Metrahit 2x Series ===


{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable"
{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable"
Line 150: Line 188:
! Count
! Count
! TRMS
! TRMS
! Supported gmc-mh-1x-2x-rs232
! Supported gmc-mh-2x-bd232
! Remarks  
! Remarks  


Line 155: Line 195:
| Metrahit 22S (M222A)
| Metrahit 22S (M222A)
|  
|  
|
| Unigor 330
|  
|  
| style="text-align:right" | 31000
| style="text-align:right" | 31000
| style="text-align:center" |  
| style="text-align:center" |  
| style="text-align:center" | ○
| style="text-align:center" | ○
| Signal Generator; Current measurement only with clamp
| Signal Generator; Current measurement only with clamp


Line 168: Line 210:
| style="text-align:right" | 31000
| style="text-align:right" | 31000
| style="text-align:center" |  
| style="text-align:center" |  
| style="text-align:center" |  ○
| style="text-align:center" | ○
| Signal Generator; Like 22S + Integrated measurement data storage
| Signal Generator; Like 22S + Integrated measurement data storage


Line 177: Line 221:
| style="text-align:right" | 31000
| style="text-align:right" | 31000
| style="text-align:center" |  
| style="text-align:center" |  
| Signal Generator; special 16A (unfused) range for used with measuring current transformers
| style="text-align:center" |  ○
| style="text-align:center" | ○
| Signal Generator; special 16A (unfused) range for use with measuring current transformers


|-
|-
Line 186: Line 232:
| style="text-align:right" | 31000
| style="text-align:right" | 31000
| style="text-align:center" |  
| style="text-align:center" |  
| style="text-align:center" |  ○
| style="text-align:center" | ○
| Signal Generator
| Signal Generator


|-
|-
| Metrahit 25S (M225A)
| [[Gossen Metrawatt Metrahit 25S | Metrahit 25S (M225A)]]
| B1102 7KB1102-8BA
| B1102 7KB1102-8BA
|  
| Unigor 355
|  
|  
| style="text-align:right" | 31000
| style="text-align:right" | 31000
| style="text-align:center" | AC
| style="text-align:center" | AC
| style="text-align:center" | ●
| style="text-align:center" | ●
| Signal Generator
| Signal Generator


Line 204: Line 254:
| style="text-align:right" | 31000
| style="text-align:right" | 31000
| style="text-align:center" |  ●
| style="text-align:center" |  ●
| style="text-align:center" |  ○
| style="text-align:center" |  ○
| Signal Generator
| Signal Generator


Line 213: Line 265:
| style="text-align:right" |
| style="text-align:right" |
| style="text-align:center" |  ●
| style="text-align:center" |  ●
| style="text-align:center" |  ○
| style="text-align:center" |  ○
| Signal Generator; Like 26S + Integrated measurement data storage
| Signal Generator; Like 26S + Integrated measurement data storage


Line 222: Line 276:
| style="text-align:right" |
| style="text-align:right" |
| style="text-align:center" |  
| style="text-align:center" |  
| style="text-align:center" | -
| style="text-align:center" | -
| Milliohm meter for explosive atmospheres
| Milliohm meter for explosive atmospheres


Line 231: Line 287:
| style="text-align:right" |
| style="text-align:right" |
| style="text-align:center" |  
| style="text-align:center" |  
| style="text-align:center" | -
| style="text-align:center" | -
| Milliohm meter for explosive atmospheres, special version approved by Airbus.
| Milliohm meter for explosive atmospheres, special version approved by Airbus.


|-
|-
| Metrahit 27I (M227B)
| [[Gossen Metrawatt Metrahit 27I|Metrahit 27I]] (M227B)
| B1107 B 7KB1107-8BA ?
| B1107 B 7KB1107-8BA ?
|
|
Line 240: Line 298:
| style="text-align:right" |
| style="text-align:right" |
| style="text-align:center" |  ●
| style="text-align:center" |  ●
| Milliohm and Megaohm, insulation tester. Same device available as part of avionic kit 27AS (M227C).
| style="text-align:center" | -
| style="text-align:center" | -
| Milliohm and Megaohm, insulation tester. ASCII-based communication protocol similiar to SCPI. Same device available as part of avionic kit 27AS (M227C).


|-
|-
Line 249: Line 309:
| style="text-align:right" |
| style="text-align:right" |
| style="text-align:center" |  ●
| style="text-align:center" |  ●
| Special tester for Electro and Hybrid Cars. Milliohm and Megaohm, insulation tester. Seems to be a METRAHit 27I in different colors
| style="text-align:center" | -
| style="text-align:center" | -
| Special tester for Electro and Hybrid Cars. Milliohm and Megaohm, insulation tester. Seems to be a [[Gossen Metrawatt Metrahit 27I|Metrahit 27I]] in different colors


|-
|-
Line 257: Line 319:
|  
|  
| style="text-align:right" |
| style="text-align:right" |
| style="text-align:center" |
| style="text-align:center" | ●
| style="text-align:center" | -
| style="text-align:center" | -
| Multimeter and Milliohmmeter
| Multimeter and Milliohmmeter


|-
|-
| [[Gossen Metrawatt Metrahit 28S | Metrahit 28S (M228A)]]
| [[Gossen Metrawatt Metrahit 28C | Metrahit 28C (M231A)]]
| [[Siemens B1105 | B1105 7KB1105-8AA]]
| Unigor 280
|
|style="text-align:right" | 310000
| style="text-align:center" |  ●
|
 
|-
| Metrahit 28C (M231A)
|  
|  
|  
|  
|  
|  
| style="text-align:right" | 310000
| style="text-align:right" | 310000
| style="text-align:center" |
| style="text-align:center" | ●
| style="text-align:center" | -
| style="text-align:center" | -
| Multimeter, Milliohmmeter + Calibrator
| Multimeter, Milliohmmeter + Calibrator


Line 284: Line 341:
|  
|  
| style="text-align:right" | (30000)
| style="text-align:right" | (30000)
| style="text-align:center" |  
| style="text-align:center" | -
| style="text-align:center" | -
| style="text-align:center" | -
| Calibrator; Only a signal generator, not a multimeter, added here just for completeness.
| Calibrator; Only a signal generator, not a multimeter, added here just for completeness.


|-
|-
| Metrahit 29S (M229A)
| [[Gossen Metrawatt Metrahit 28S | Metrahit 28S (M228A)]]
| [[Siemens B1105 | B1105 7KB1105-8AA]]
| Unigor 380
|
| style="text-align:right" | 310000
| style="text-align:center" | ●
| style="text-align:center" | ●
| style="text-align:center" | ●
|
 
|-
| [[Gossen Metrawatt Metrahit 29S | Metrahit 29S (M229A)]]
| B1106 7KB1106-8AA
| B1106 7KB1106-8AA
| Unigor 290
| Unigor 390
| PowerLogger 10
| PowerLogger 10
| style="text-align:right" |310000
| style="text-align:right" |310000
| style="text-align:center" |  ●
| style="text-align:center" |  ●
| Energy and power disturbance measurement functions, integrated memory.
| style="text-align:center" |  ●
| style="text-align:center" |  (○)
| Energy and power disturbance measurement functions, integrated memory. Energy measurement functions not implemented yet for driver gmc-mh-2x-bd232.


|-
|-
Line 303: Line 375:
| style="text-align:right" |1200000
| style="text-align:right" |1200000
| style="text-align:center" |  ●
| style="text-align:center" |  ●
| Laboratory multimeter; communication protocol not compatible with Metrahit 1x/2x devices!
| style="text-align:center" | -
| style="text-align:center" | -
| Laboratory multimeter; special communication protocol not compatible with other Metrahit 1x/2x devices!
|}
|}


The Metrahit 2x series supports bidirectional data exchange via IR.
The Metrahit 2x series supports unidirectional (''Send Mode'') and bidirectional data exchange via IR.
 
Currently the ''Metrahit 25S'' and ''28S (Siemens B1105)'' are supported by two different drivers:
* gmc-mh-1x-2x-rs232: ''Send Mode''
* gmc-mh-2x-bd232: ''Bidirectional Mode''


Currently the ''Metrahit 28S'' with unidirectional interface [[Gossen_Metrawatt#Metrahit_RS232|RS232]] is supported by ''sigrok'' using the driver ''gmc-mh-1x-2x-rs232''. The other devices will work probably, but are untested. Please contact [[User:Matthias_Heidbrink|Matthias]] if you have one of these devices and can test it.
The models marked with ○ in a <i>Supported</i> row are untested, but expected to work. Please contact [[User:Matthias_Heidbrink|Matthias]] if you have one of these unsupported devices and can test it.


== Metrahit Starline Series ==
See [[#Communication_Protocols | Communication Protocols]] for more details.
 
=== Metrahit Starline Series ===
The series of newer devices with only three sockets (only one socket for all current measurement ranges) is called ''Starline Series''. The manufacturer sub-divides this further into an ''A Series'', ''E Series'' and ''S Series'', which does not make a big difference concerning communicating with the devices.
The series of newer devices with only three sockets (only one socket for all current measurement ranges) is called ''Starline Series''. The manufacturer sub-divides this further into an ''A Series'', ''E Series'' and ''S Series'', which does not make a big difference concerning communicating with the devices.


Line 319: Line 399:
! Dranetz brand
! Dranetz brand
! Count
! Count
! Supported
! Remarks  
! Remarks  
|-
|-
| Metrahit X-Tra (M240A)
| [[Gossen Metrawatt Metrahit X-Tra|Metrahit X-Tra (M240A)]]
| Siemens B1125 7KB1125-8AA
| Siemens B1125 7KB1125-8AA
| Drantech XTRA
| Drantech XTRA
| style="text-align:right" | 12000
| style="text-align:right" | 12000
| style="text-align:center" | -
| Teardown on EEVblog: [http://www.eevblog.com/2009/11/29/eevblog-46-gossen-metrawatt-xtra-multimeter-review/ 1]
| Teardown on EEVblog: [http://www.eevblog.com/2009/11/29/eevblog-46-gossen-metrawatt-xtra-multimeter-review/ 1]
|-
|-
Line 331: Line 413:
| DranTech Outdoor
| DranTech Outdoor
| style="text-align:right" | 12000
| style="text-align:right" | 12000
| style="text-align:center" | -
| IP65; seems to be a more rugged, different-coloured flavour of the X-Tra
| IP65; seems to be a more rugged, different-coloured flavour of the X-Tra
|-
|-
Line 337: Line 420:
|  
|  
| style="text-align:right" | 12000
| style="text-align:right" | 12000
| style="text-align:center" | -
| Seems to be a white, "medical" version of the X-Tra
| Seems to be a white, "medical" version of the X-Tra
|-
|-
Line 343: Line 427:
|  
|  
| style="text-align:right" | 60000
| style="text-align:right" | 60000
| style="text-align:center" | -
|  
|  
|-
|-
Line 349: Line 434:
|  
|  
| style="text-align:right" | 60000
| style="text-align:right" | 60000
| style="text-align:center" | -
|  
|  
|-
|-
Line 355: Line 441:
|  
|  
| style="text-align:right" | 60000
| style="text-align:right" | 60000
| style="text-align:center" | -
| Simular to Extra, but fewer functions.
| Simular to Extra, but fewer functions.
|-
|-
Line 361: Line 448:
|  
|  
| style="text-align:right" | 60000
| style="text-align:right" | 60000
| style="text-align:center" | -
|  
|  
|-
|-
Line 367: Line 455:
|  
|  
| style="text-align:right" | 60000
| style="text-align:right" | 60000
| style="text-align:center" | -
| Energy and power analysis functions; EEVblog: Teardown: [http://www.eevblog.com/2011/05/27/eevblog-173-gossen-metrahit-energy-multimeter-teardown/ 1] Battery measurement: [http://www.eevblog.com/2011/01/27/eevblog-141-aa-alkaline-battery-capacity-measurement/ 2]
| Energy and power analysis functions; EEVblog: Teardown: [http://www.eevblog.com/2011/05/27/eevblog-173-gossen-metrahit-energy-multimeter-teardown/ 1] Battery measurement: [http://www.eevblog.com/2011/01/27/eevblog-141-aa-alkaline-battery-capacity-measurement/ 2]
|-
|-
Line 373: Line 462:
|  
|  
| style="text-align:right" | 310000
| style="text-align:right" | 310000
| style="text-align:center" | -
| Precision Multimeter
| Precision Multimeter
|-
|-
Line 379: Line 469:
|  
|  
| style="text-align:right" | 310000
| style="text-align:right" | 310000
| style="text-align:center" | -
| Precision Multimeter with additional Bluetooth interface
| Precision Multimeter with additional Bluetooth interface
|-
|-
Line 385: Line 476:
| DranTech ISO
| DranTech ISO
| style="text-align:right" | 30000
| style="text-align:right" | 30000
| style="text-align:center" | -
| Multimeter with insulation measurement 50/100/250/500/1000 V, 3,1 GΩ
| Multimeter with insulation measurement 50/100/250/500/1000 V, 3,1 GΩ
|-
|-
Line 391: Line 483:
|  
|  
| style="text-align:right" | 30000
| style="text-align:right" | 30000
| style="text-align:center" | -
| Multimeter with insulation measurement 10/50/100/250/500/1000 V, 3,1 GΩ
| Multimeter with insulation measurement 10/50/100/250/500/1000 V, 3,1 GΩ
|-
|-
| Metrahit T-Com (M246A)
| Metrahit T-Com (M246A)
Line 397: Line 491:
|  
|  
| style="text-align:right" | 3100
| style="text-align:right" | 3100
| style="text-align:center" | -
| Multimeter with special functions for symmetrical copper wiring, insulation measurement 100V
| Multimeter with special functions for symmetrical copper wiring, insulation measurement 100V
|-
|-
| Metrahit T-Com Plus (M246S)
| Metrahit T-Com Plus (M246S)
Line 403: Line 499:
|  
|  
| style="text-align:right" | 3100
| style="text-align:right" | 3100
| style="text-align:center" | -
| Like T-Com, some more functions.
| Like T-Com, some more functions.
|-
| Metrahit Coil (M246C)
|
|
| style="text-align:right" | 31000
| style="text-align:center" | -
| Special functions for measuring electric drives and insulation measurement
|-
|-
| Metracal MC (M245A)
| Metracal MC (M245A)
Line 409: Line 515:
|  
|  
| style="text-align:right" | 60000
| style="text-align:right" | 60000
| style="text-align:center" | -
| Multimeter and calibrator; older versions named ''Metrahit Multical''.
| Multimeter and calibrator; older versions named ''Metrahit Multical''.
|-
|-
|}
|}


== Metraport Series ==
=== Metraport Series ===
{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable"
{| border="0" style="font-size: smaller" class="alternategrey sortable sigroktable"
|-  
|-  
Line 421: Line 528:
! Remarks  
! Remarks  
|-
|-
| Metraport 40S (M234D)
| [[Gossen Metrawatt Metraport 40S|Metraport 40S]] (M234D)
| V.A.G 1526E
| V.A.G 1526E
| style="text-align:right" | 30000
| style="text-align:right" | 30000
Line 428: Line 535:
|}
|}


= Communication Hardware =
== Communication Hardware ==
Most Gossen Metrawatt multimeters having data communication support communicate unidirectionally or bi-directionally through the case using IR and proprietary communication adaptors. The advantage of this construction is that it allows a closed case without unnecessary holes (one model, the ''Metrahit Outdoor'', even has IP65 protection!), the disadvantage is a need for special, expensive adaptors to convert this to common RS232 or USB. Please note that the IR is just serial data (?), not IrDA.  
Most Gossen Metrawatt multimeters having data communication support communicate unidirectionally or bi-directionally through the case using IR and proprietary communication adaptors. The advantage of this construction is that it allows a closed case without unnecessary holes. One model, the ''Metrahit Outdoor'', even has IP65 protection! The disadvantage is a need for special, expensive adaptors to convert this to common RS232 or USB.  


The ''Metrahit Ultra BT'' also supports Bluetooth.  
The IR signal is just serial data encoded as SIR (''Asynchronous <u>S</u>erial <u>I</u>nfra<u>r</u>ed''; signal inverted, bits only about 3/16 of the ordinary length). While SIR is the physical layer of IrDA for lower baud rates, an IrDA communication adaptor will not work because it implements further protocols on top. Some details (optical specification; 8192 baud and 6 bit modes required by some multimeters) seem not to conform to the SIR specs.


== Metrahit 1x/2x series ==
The ''Metrahit Ultra BT'' also supports Bluetooth. The ''Metraport 40S'' communicates via integrated USB only.
=== Metrahit RS232 ===
 
=== Metrahit 1x/2x series ===
==== Metrahit RS232 ====
IR→RS232 adaptor for unidirectional communication from the multimeter to the computer.  
IR→RS232 adaptor for unidirectional communication from the multimeter to the computer.  


Line 441: Line 550:
RS232 parameters: 8192 (Metrahit 1x)/9600 Baud (Metrahit 2x), 6N1, DTR ON, RTS ON.
RS232 parameters: 8192 (Metrahit 1x)/9600 Baud (Metrahit 2x), 6N1, DTR ON, RTS ON.


The communication speed of 8192 Baud might not be supported by some operating systems and RS232-USB adaptors.  
The communication speed of 8192 Baud and 6 data bits might not be supported by some operating systems and many [[Serial port#USB to serial converters|RS232-USB adaptors]].  


Not available any more.
Not available any more.
Line 451: Line 560:
</gallery>
</gallery>


=== Metrahit SI232 ===
The adaptor contains just discrete components and ICs, no microcontroller.
 
==== Metrahit SI232 ====
IR→RS232 adaptor for unidirectional communication from the multimeter to the computer and data storage.  
IR→RS232 adaptor for unidirectional communication from the multimeter to the computer and data storage.  


Line 460: Line 571:
128 kByte battery-buffered CMOS memory, up to about 100000 data sets.
128 kByte battery-buffered CMOS memory, up to about 100000 data sets.


Multimeter: 8192 Baud, 950 nm, 6N1 (?).<br/>
Multimeter: 8192 Baud, 950 nm, 6N1.<br/>
RS232: 9600/19200/38400 Baud, 8N1.
RS232: 9600/19200/38400 Baud, 8N1.


Not available from Gossen Metrawatt any more. It seems that Rishab in India [http://rishabh.co.in/ 1] still sells it as OEM product ''Rish SI232''.
Not available from Gossen Metrawatt any more. It seems that Rishab in India [http://rishabh.co.in/ 1] still sells it as OEM product ''Rish SI232''.


=== Metrahit BD232 ===
==== Metrahit BD232 ====
IR↔RS232 adaptor allowing bidirectional communication between multimeter and computer.
IR↔RS232 adaptor allowing bidirectional communication between multimeter and computer.


Works with Metrahit 2x devices, including 30M.
Works with Metrahit 1x and 2x devices and the 30M.


Up to six ''BD232'' can be cascaded to communicate to the computer via a single RS232 interface. When only Metrahit 2x multimeters are used, ''BD232'' and ''SI232'' adaptors can be mixed.
With Metrahit 2x/30M devices up to six ''BD232'' can be cascaded to communicate to the computer via a single RS232 interface. When only Metrahit 2x multimeters are used, ''BD232'' and ''SI232'' adaptors can be mixed.


9600/19200/38400 Baud.
9600 Baud.


=== Metrahit SI232 II ===
<gallery>
File:Gossen Metrawatt BD232 1.jpg|<small>Left side</small>
File:Gossen Metrawatt BD232 2.jpg|<small>Right side</small>
File:Gossen Metrawatt BD232 3.jpg|<small>Inside</small>
File:Gossen Metrawatt BD232 4.jpg|<small>Board bottom</small>
File:Gossen Metrawatt BD232 5.jpg|<small>Board top</small>
</gallery>
 
The adaptor contains just discrete components and ICs, no microcontroller.
 
==== Metrahit SI232-II ====
IR↔RS232 adaptor allowing bidirectional communication between multimeter and computer and data storage.
IR↔RS232 adaptor allowing bidirectional communication between multimeter and computer and data storage.


Line 484: Line 605:
RS232: 9600/19200/38400 Baud, 8N1.
RS232: 9600/19200/38400 Baud, 8N1.


4-8 ''SI232 II'' (depending on multimeter types and baud rate) can be cascaded to communicate to the computer via a single RS232 interface. Up to 10 ''SI232 II'' can be cascaded to measure offline synchronously.
4-8 ''SI232-II'' (depending on multimeter types and baud rate) can be cascaded to communicate to the computer via a single RS232 interface. Up to 10 ''SI232-II'' can be cascaded to measure offline synchronously.


Not available any more.
Not available any more.


=== USB-Hit ===
<gallery>
File:LEM Unigor mem 232 II 1.jpg|<small>LEM Unigor mem 232 II (OEM version of SI232-II)</small>
File:LEM Unigor mem 232 II 2.jpg|<small>Inside</small>
</gallery>
 
==== USB-Hit ====
IR↔USB adaptor for Metrahit.  
IR↔USB adaptor for Metrahit.  


For Metrahit 2x/30M devices only.
For Metrahit 2x/30M devices only.


== Metrahit Starline Series ==
=== Metrahit Starline Series ===
=== USB X-Tra ===
==== USB X-Tra ====
IR↔USB adaptor for the ''Starline Series'' devices.
IR↔USB adaptor for the ''Starline Series'' devices.


== Bluetooth ==
A USB to SIR converter like [http://lemmini.de/IrDA%20USB/IrDA%20USB.html this nice Open Souce hardware design by 0xdeadbeef/V. Ott]  will work as a cheaper replacement.
 
==== Bluetooth ====
Bluetooth 2.1 + EDR, Class 2
Bluetooth 2.1 + EDR, Class 2


For the ''Metrahit Ultra BT''.
For the ''Metrahit Ultra BT''.


= Communication Protocols =
=== Metraport Series ===
==== USB ====
The ''Metraport 40S'' has got an integrated USB 1.1 interface with USB Mini-B receptacle.
 
== Communication Protocols ==
While the older devices MetraHit 1x-30M use proprietary protocols, the newer devices of the socalled ''Starline Series'' use a protocol close to SCPI. Descriptions of the communication protocols are available from the manufacturer.  
While the older devices MetraHit 1x-30M use proprietary protocols, the newer devices of the socalled ''Starline Series'' use a protocol close to SCPI. Descriptions of the communication protocols are available from the manufacturer.  


== Metrahit 1x/2x Send Mode ==
=== Metrahit 1x/2x Send Mode ===
Proprietary binary protocol. Used for sending data to PC.
Proprietary binary protocol. Used for sending data from multimeter to PC.
 
This mode is supported by the driver ''gmc-mh-1x-2x-rs232'' using the interface [[#Metrahit_RS232|RS232]]. <!-- or [[#Metrahit_SI232-II|SI232-II]]. The interface [[#Metrahit_SI232|SI232]] should work, too, but is untested. BD232? -->
 
Supported devices: ''Metrahit 14A'', ''15S (HT410)'', ''16I'', ''KMM2002'', ''18S'', ''25S'', ''28S'' (Siemens B1105), ''29S''.
 
Other devices of the Metrahit 1x/2x series except the 18C/27x/28Cx devices should work, too, but are untested.
 
=== Metrahit 2x Bidirectional Mode ===
Proprietary binary protocols. Used for bidirectional communication between computer and most Metrahit 2x multimeters.
 
There seem to be several "sub-modes". See description available from manufacturer on request.
 
This mode is supported (incompletely) by the driver ''gmc-mh-2x-bd232'' using one of the interfaces [[#Metrahit_BD232|BD232]] or [[#Metrahit_SI232-II|SI232-II]]. The interface [[#USB-Hit|USB-Hit]] might work, too, but is untested.
 
The driver will try to power on BD232 and SI232-II interfaces and connected multimeters before scanning for devices.
The driver can power off a multimeter using the command SR_CONF_POWER_OFF with a boolean parameter of TRUE.
 
Supported devices: Metrahit 25S and ''Siemens B1105'' (Metrahit 28S). Other multimeters of the series should work, too, but are untested.


== Metrahit 1x/2x Block Send Mode ==
Currently the following restrictions apply:
Proprietary binary protocol. Used for polling buffered data from PC.
* Only one multimeter per RS-232 interface supported. Several multimeters on cascaded ''BD232'' or ''SI232-II'' interfaces might be detected, but only one at a time can be used.
* Measured values are read one by one by polling. Depending on the sample rate, this could theoretically cause loss of some values.
* Reading of data stored in memory of storage adaptor SI232-II or multimeter (Metrahit 22M, 26M, 29S) not implemented yet.
* Setting of multimeter configuration not supported yet.


== Metrahit 2x Other modes ==
=== Metrahit 30M ===
There seem to be 2 or 3 other communication modes for the Metrahit 2x series. See description available from manufacturer.
The protocol is proprietary and seems to be quite different from the Metrahit 1x/2x series although communication can use some of the same IR↔Serial adaptors (at least [[Gossen Metrawatt#Metrahit_BD232|BD232]], [[Gossen Metrawatt#USB_Hit|USB-Hit]]).


== Metrahit 30M ==
=== Metrahit 27I, 27M, 28C, Starline Series, Metraport 40S ===
The protocol is proprietary and seems to be quite different from the Metrahit 1x/2x series although communication can use some of the same IR↔RS232 adaptors (at least [[Gossen Metrawatt#Metrahit_BD232|BD232]], [[Gossen Metrawatt#USB_Hit|USB-Hit]]).
Newer Metrahit devices use a proprietary communication protocol that is (mostly) ASCII and oriented at SCPI. A driver is under development.


== Starline Series, Metraport 40S ==
Depending on the device type, an interface ''[[#Metrahit_BD232|BD232]]'' or ''[[#USB-Hit|USB-Hit]]'' for ''Metrahit 27x'' or ''28C'', ''[[#USB X-Tra|USB X-Tra]]'' for supported devices of the ''Starline Series'' or an USB cable with a type Mini-B plug for the ''Metraport 40S'' is required.
Newer Metrahit devices use a proprietary communication protocol that is basically SCPI with an escape mechanism for some special chars.


== LabView ==
=== LabView ===
Gossen Metrawatt offers LabView drivers for the ''Metrahit Energy'', the ''Metrahit Ultra'' and the ''Metraport 40S''.
Gossen Metrawatt offers LabView drivers for the ''Metrahit Energy'', the ''Metrahit Ultra'' and the ''Metraport 40S''.


= See also =
== See also ==
* [[BBC Goertz Metrawatt M2110]]
* [[BBC Goertz Metrawatt M2110]]


[[Category:Manufacturer]]
[[Category:Manufacturer]]
[[Category:Planned]]

Latest revision as of 10:14, 5 February 2017

Gossen Metrawatt is a German manufacturer of professional and high-end test and measurement equipment, including multimeters.

This article tries to give an overview of the multimeters with interfaces for data exchange, OEM models and communication.

Company

Multimeters

One remark concerning device names: The manufacturer writes the name of the device series sometimes "METRAHit", sometimes METRAHIT or even METRA HIT, sometimes not even consistently for the same device. For simplicity it will be "Metrahit" here most of the time, other names alike.

Metrahit 1x series

Gossen Metrawatt Siemens OEM Rishabh HT OEM Count TRMS Supported Remarks
Metrahit 12S (GTM 2012 000 R0003) Rishmulti 12S 3100 -
Metrahit 13S (GTM 2013 000 R0003) Rishmulti 13S 3100 -
Metrahit 14A (GTM 2014 000 R0007) B1102 7KB1102-8AA 3100 -
Metrahit 14S (GTM 2014 000 R0003) B1103 7KB1103-8AA Rishmulti 14S 3100 - Tested successfully by a sigrok user.
Metrahit ONE PLUS (M204D) [1] 3100 - Seems to be the successor of the 14S, detected as 14S. Tested successfully by a sigrok user.
Metrahit 15S (GTM 2015 000 R0003) Rishmulti 15S HT Instruments HT410 3100 -
Metrahit 16S (GTM 2016 000 R0003) B1104 7KB1104-8AA Rishmulti 16S 3100
Metrahit 16I (M216B) 3100 Multimeter and insulation tester 500/1000 V
Metrahit 16L (M216L) 3100 Seems to be a Metrahit 16I with additional duty cycle function
Metrahit 16T (M216A) 3100 Multimeter and insulation tester 100 V telecom; seems to be almost identical to T-Com KMM2002.
T-Com KMM2002 (M216T) 3100 Multimeter and insulation tester 100 V telecom
Metrahit 16U (M216U) 3100 Multimeter and insulation tester for symmetrical copper wire, very similar to 16T
Metrahit 18C - Calibrator; This device is a signal generator, not a multimeter, and seems to have not much in common with the multimeters except the case. Added here just for completeness.
Metrahit 18S (GTM 2018 000 R0003) B1108 7KB1108-8AA Rishmulti 18S 31000


These multimeter can send data unidirectionally via IR/RS232 (Send Mode). It seems that the 3100 count types are actually 31000 count types that do not display the last digit, but can deliver it via the serial interface.

Currently the Metrahit 14A, 14S, ONE Plus, 15S (HT410), 16I, KMM2002 and 18S are supported by sigrok using the driver gmc-mh-1x-2x-rs232.

The models marked with ○ in the Supported row are untested, but expected to work. See section Metrahit 1x/2x Send Mode for details.

Please contact Matthias if you have one of the unsupported devices and can test it.

The devices are not available from Gossen Metrawatt any more, but it seems that a company in India named Rishabh makes slightly redesigned versions of some models. The HT Instruments HT410 seems to be another OEM model, probably made by Rishabh.

The Metrahit 1x series includes some more devices (Metrahit 15 and 16 without letter, Milliohm Meter Metrahit 17, some sold as ancestor brand ABB Metrawatt) that are unsupported because they do not have an IR interface.

Metrahit 2x Series

Gossen Metrawatt Siemens OEM LEM ELMES/
HEME/NORMA OEM
Dranetz brand Count TRMS Supported gmc-mh-1x-2x-rs232 Supported gmc-mh-2x-bd232 Remarks
Metrahit 22S (M222A) Unigor 330 31000 Signal Generator; Current measurement only with clamp
Metrahit 22M (M222B) 31000 Signal Generator; Like 22S + Integrated measurement data storage
Metrahit 23S (M223A) 31000 Signal Generator; special 16A (unfused) range for use with measuring current transformers
Metrahit 24S (M224A) 31000 Signal Generator
Metrahit 25S (M225A) B1102 7KB1102-8BA Unigor 355 31000 AC Signal Generator
Metrahit 26S (M226A) 31000 Signal Generator
Metrahit 26M (M226B) Signal Generator; Like 26S + Integrated measurement data storage
Metrahit 27EX (M227F) - - Milliohm meter for explosive atmospheres
Metrahit 27EX Airbus (M227G) - - Milliohm meter for explosive atmospheres, special version approved by Airbus.
Metrahit 27I (M227B) B1107 B 7KB1107-8BA ? DranTech PMIT - - Milliohm and Megaohm, insulation tester. ASCII-based communication protocol similiar to SCPI. Same device available as part of avionic kit 27AS (M227C).
Metrahit H+E Car (M227T) - - Special tester for Electro and Hybrid Cars. Milliohm and Megaohm, insulation tester. Seems to be a Metrahit 27I in different colors
Metrahit 27M (M227A) - - Multimeter and Milliohmmeter
Metrahit 28C (M231A) 310000 - - Multimeter, Milliohmmeter + Calibrator
Metrahit 28C light (M232A) (30000) - - - Calibrator; Only a signal generator, not a multimeter, added here just for completeness.
Metrahit 28S (M228A)  B1105 7KB1105-8AA Unigor 380 310000
Metrahit 29S (M229A) B1106 7KB1106-8AA Unigor 390 PowerLogger 10 310000 (○) Energy and power disturbance measurement functions, integrated memory. Energy measurement functions not implemented yet for driver gmc-mh-2x-bd232.
Metrahit 30M (M230B) DranTech ULTRA 1200000 - - Laboratory multimeter; special communication protocol not compatible with other Metrahit 1x/2x devices!

The Metrahit 2x series supports unidirectional (Send Mode) and bidirectional data exchange via IR.

Currently the Metrahit 25S and 28S (Siemens B1105) are supported by two different drivers:

  • gmc-mh-1x-2x-rs232: Send Mode
  • gmc-mh-2x-bd232: Bidirectional Mode

The models marked with ○ in a Supported row are untested, but expected to work. Please contact Matthias if you have one of these unsupported devices and can test it.

See Communication Protocols for more details.

Metrahit Starline Series

The series of newer devices with only three sockets (only one socket for all current measurement ranges) is called Starline Series. The manufacturer sub-divides this further into an A Series, E Series and S Series, which does not make a big difference concerning communicating with the devices.

Gossen Metrawatt Siemens OEM Dranetz brand Count Supported Remarks
Metrahit X-Tra (M240A) Siemens B1125 7KB1125-8AA Drantech XTRA 12000 - Teardown on EEVblog: 1
Metrahit Outdoor (M240o) DranTech Outdoor 12000 - IP65; seems to be a more rugged, different-coloured flavour of the X-Tra
Seculife Hit (M687A) 12000 - Seems to be a white, "medical" version of the X-Tra
Metrahit EBase (M251A) 60000 -
Metrahit ESpecial (M252A) 60000 -
Metrahit ETech (M253A) 60000 - Simular to Extra, but fewer functions.
Metrahit Extra (M250A) 60000 -
Metrahit Energy (M249A) 60000 - Energy and power analysis functions; EEVblog: Teardown: 1 Battery measurement: 2
Metrahit Ultra (M248A) 310000 - Precision Multimeter
Metrahit Ultra BT (M248B) 310000 - Precision Multimeter with additional Bluetooth interface
Metrahit Iso (M246B) DranTech ISO 30000 - Multimeter with insulation measurement 50/100/250/500/1000 V, 3,1 GΩ
Metrahit Iso Aero (M246M) 30000 - Multimeter with insulation measurement 10/50/100/250/500/1000 V, 3,1 GΩ
Metrahit T-Com (M246A) 3100 - Multimeter with special functions for symmetrical copper wiring, insulation measurement 100V
Metrahit T-Com Plus (M246S) 3100 - Like T-Com, some more functions.
Metrahit Coil (M246C) 31000 - Special functions for measuring electric drives and insulation measurement
Metracal MC (M245A) 60000 - Multimeter and calibrator; older versions named Metrahit Multical.

Metraport Series

Gossen Metrawatt Volkswagen OEM Count Remarks
Metraport 40S (M234D) V.A.G 1526E 30000 Foldable multimeter; USB interface, resettable fuse

Communication Hardware

Most Gossen Metrawatt multimeters having data communication support communicate unidirectionally or bi-directionally through the case using IR and proprietary communication adaptors. The advantage of this construction is that it allows a closed case without unnecessary holes. One model, the Metrahit Outdoor, even has IP65 protection! The disadvantage is a need for special, expensive adaptors to convert this to common RS232 or USB.

The IR signal is just serial data encoded as SIR (Asynchronous Serial Infrared; signal inverted, bits only about 3/16 of the ordinary length). While SIR is the physical layer of IrDA for lower baud rates, an IrDA communication adaptor will not work because it implements further protocols on top. Some details (optical specification; 8192 baud and 6 bit modes required by some multimeters) seem not to conform to the SIR specs.

The Metrahit Ultra BT also supports Bluetooth. The Metraport 40S communicates via integrated USB only.

Metrahit 1x/2x series

Metrahit RS232

IR→RS232 adaptor for unidirectional communication from the multimeter to the computer.

Works with Metrahit 1x and with Metrahit 2x devices in Send Mode.

RS232 parameters: 8192 (Metrahit 1x)/9600 Baud (Metrahit 2x), 6N1, DTR ON, RTS ON.

The communication speed of 8192 Baud and 6 data bits might not be supported by some operating systems and many RS232-USB adaptors.

Not available any more.

The adaptor contains just discrete components and ICs, no microcontroller.

Metrahit SI232

IR→RS232 adaptor for unidirectional communication from the multimeter to the computer and data storage.

Works with Metrahit 1x and with Metrahit 2x devices in Send Mode.

Up to six SI232 can be cascaded to communicate to the computer via a single RS232 interface. Up to 10 SI232 can be cascaded to measure offline synchronously.

128 kByte battery-buffered CMOS memory, up to about 100000 data sets.

Multimeter: 8192 Baud, 950 nm, 6N1.
RS232: 9600/19200/38400 Baud, 8N1.

Not available from Gossen Metrawatt any more. It seems that Rishab in India 1 still sells it as OEM product Rish SI232.

Metrahit BD232

IR↔RS232 adaptor allowing bidirectional communication between multimeter and computer.

Works with Metrahit 1x and 2x devices and the 30M.

With Metrahit 2x/30M devices up to six BD232 can be cascaded to communicate to the computer via a single RS232 interface. When only Metrahit 2x multimeters are used, BD232 and SI232 adaptors can be mixed.

9600 Baud.

The adaptor contains just discrete components and ICs, no microcontroller.

Metrahit SI232-II

IR↔RS232 adaptor allowing bidirectional communication between multimeter and computer and data storage.

Works with Metrahit 1x and Metrahit 2x devices.

128 kByte battery-buffered CMOS memory, up to about 100000 data sets.

Multimeter: 8192/9600 Baud, 950 nm, 8N1.
RS232: 9600/19200/38400 Baud, 8N1.

4-8 SI232-II (depending on multimeter types and baud rate) can be cascaded to communicate to the computer via a single RS232 interface. Up to 10 SI232-II can be cascaded to measure offline synchronously.

Not available any more.

USB-Hit

IR↔USB adaptor for Metrahit.

For Metrahit 2x/30M devices only.

Metrahit Starline Series

USB X-Tra

IR↔USB adaptor for the Starline Series devices.

A USB to SIR converter like this nice Open Souce hardware design by 0xdeadbeef/V. Ott will work as a cheaper replacement.

Bluetooth

Bluetooth 2.1 + EDR, Class 2

For the Metrahit Ultra BT.

Metraport Series

USB

The Metraport 40S has got an integrated USB 1.1 interface with USB Mini-B receptacle.

Communication Protocols

While the older devices MetraHit 1x-30M use proprietary protocols, the newer devices of the socalled Starline Series use a protocol close to SCPI. Descriptions of the communication protocols are available from the manufacturer.

Metrahit 1x/2x Send Mode

Proprietary binary protocol. Used for sending data from multimeter to PC.

This mode is supported by the driver gmc-mh-1x-2x-rs232 using the interface RS232.

Supported devices: Metrahit 14A, 15S (HT410), 16I, KMM2002, 18S, 25S, 28S (Siemens B1105), 29S.

Other devices of the Metrahit 1x/2x series except the 18C/27x/28Cx devices should work, too, but are untested.

Metrahit 2x Bidirectional Mode

Proprietary binary protocols. Used for bidirectional communication between computer and most Metrahit 2x multimeters.

There seem to be several "sub-modes". See description available from manufacturer on request.

This mode is supported (incompletely) by the driver gmc-mh-2x-bd232 using one of the interfaces BD232 or SI232-II. The interface USB-Hit might work, too, but is untested.

The driver will try to power on BD232 and SI232-II interfaces and connected multimeters before scanning for devices. The driver can power off a multimeter using the command SR_CONF_POWER_OFF with a boolean parameter of TRUE.

Supported devices: Metrahit 25S and Siemens B1105 (Metrahit 28S). Other multimeters of the series should work, too, but are untested.

Currently the following restrictions apply:

  • Only one multimeter per RS-232 interface supported. Several multimeters on cascaded BD232 or SI232-II interfaces might be detected, but only one at a time can be used.
  • Measured values are read one by one by polling. Depending on the sample rate, this could theoretically cause loss of some values.
  • Reading of data stored in memory of storage adaptor SI232-II or multimeter (Metrahit 22M, 26M, 29S) not implemented yet.
  • Setting of multimeter configuration not supported yet.

Metrahit 30M

The protocol is proprietary and seems to be quite different from the Metrahit 1x/2x series although communication can use some of the same IR↔Serial adaptors (at least BD232, USB-Hit).

Metrahit 27I, 27M, 28C, Starline Series, Metraport 40S

Newer Metrahit devices use a proprietary communication protocol that is (mostly) ASCII and oriented at SCPI. A driver is under development.

Depending on the device type, an interface BD232 or USB-Hit for Metrahit 27x or 28C, USB X-Tra for supported devices of the Starline Series or an USB cable with a type Mini-B plug for the Metraport 40S is required.

LabView

Gossen Metrawatt offers LabView drivers for the Metrahit Energy, the Metrahit Ultra and the Metraport 40S.

See also