Gossen Metrawatt Metrahit 16I
Revision as of 23:47, 1 November 2013 by Matthias Heidbrink (talk | contribs)
Status | in progress |
---|---|
Counts | 3100 (31000) |
IEC 61010-1 | CAT III 1000 V, CAT IV 600 V |
Connectivity | Infrared (RS232) |
Measurements | voltage, current, resistance, capacitance, temperature, diode, continuity |
Features | autorange, data hold, bargraph |
Website | [1] |
The Gossen Metrawatt Metrahit 16I is a 3100 counts handheld digital multimeter with IR (RS232) connectivity and insulation measurement (500/1000 V).
The resolution is one digit higher on the data interface.
Hardware
- Fuse: None!
- TODO.
Photos
Measurement functions and ranges
The following table is a work in progress and currently inaccurate!
Measurement function | Range | Resolution | Error | Remarks |
---|---|---|---|---|
V= | 30 mV | 10 μV | ±(0,5% + 3) | Not within autorange, use manual range |
300 mV | 100 μV | ±(0,5% + 3) | Not within autorange, use manual range | |
3 V | 1 mV | ±(0,25% + 1) | ||
30 V | 10 mV | |||
300 V | 100 mV | |||
600 V | 1 V | ±(0,35% + 1) | ||
V≈ | 3 V | 100 μV | ±(0,5% + 30) (> 300 Digit) | |
30 V | 100 μV | |||
300 V | 1 mV | |||
1000 V | 10 mV | |||
V≃ | 3 V | 100 μV | ±(0,5% + 30) (> 300 Digit) | |
30 V | 100 μV | |||
300 V | 1 mV | |||
1000 V | 10 mV | |||
A≈ (Clamp only) | 30 A | 10 mA | Current clamp with 100 mV/A required, e.g. GMC WZ12B | |
100 A | 100 mA | |||
Ω | 30.00 Ω | 10 mΩ | ||
300.0 Ω | 100 mΩ | |||
3.000 kΩ | 1 Ω | |||
30.00 kΩ | 10 Ω | |||
300.0 kΩ | 100 Ω | |||
3.000 MΩ | 1 kΩ | |||
30.00 MΩ | 10 kΩ | |||
Diode/Cont. | 3.0000 V– | 1 mV | ||
Cap. F | 30.00 nF | 10 pF | ||
300.0 nF | 100 pF | |||
3.000 µF | 1 nF | |||
30.00 µF | 10 nF | |||
Hz | 300.00 Hz | 0.01 Hz | ±(0.1% + 3) | |
3.0000 kHz | 0.1 Hz | |||
30.000 kHz | 1 Hz | |||
100.000 kHz | 10 Hz | |||
°C | Pt100 | –200.0 - +100.0 °C | 0.1 °C | 0,5 °C + 3 |
+100.0 - +850.0 °C | ||||
Pt1000 | –100.0 - +100.0 °C | |||
+100.0 - +850.0 °C | ||||
Event count | ||||
Stop Watch |