EXTECH 407760
Jump to navigation
Jump to search
File:Extech 407760.jpg | |
Status | planned |
---|---|
Source code | tondaj-sl814 |
Connectivity | tbd |
Frequency range | tbd |
Measurement range (A) | tbd |
Resolution | tbd |
Accuracy (94dB@1kHz) | tbd |
Frequency weighting | tbd |
Time weighting | tbd |
Website | extech407760.cn |
The EXTECH 407760 is a sound level meter with USB connectivity.
See EXTECH 407760/Info for more details (such as lsusb -vvv output) about the device.
See EXTECH 407760/Beagle_dump for more details on protocol
Hardware
Device:
- Main CPU: TBD
- TBD
- TBD
- TBD
- TBD
it's hard to read the chip numbers There's two chips on this side of the board. Same markings on both They have the TI logo TI 062C 15K CV8J
USB cable:
- TBD
Photos
Device:
- Extech 407760.jpg
USB cable:
TBD
Protocol
The device has a usb connector. The device accepts bulk transfer commands on a usb bus.
Commands / replies
407760(EXTECH) Communication Protocol Basic setup (64 byte in all, latter is 0) 0 1 2 3 4 5 6 7 8 9 10 11 LED STATUS Samprate Alarm HI Alarm Low y m d H M S Samp points 10 20 30 0 U8 U8 U8 U8 U8 U8 U8 U8 U8 U8 3U8 STATUS: 7 6 5 4 3 2 1 0 Auto:0 Manual:1 RT 1 STOR 0 1dBA 0dBC 1fast 0slow S:01 M:10 H:11 Samprate 0x01 represent 50ms 0x02 500ms 0x03 1s 0x04 2s 0x05 5s 0x06 10s 0x07 60s Download the data PC transmits the read-command 00,00,0D in read Mode. If the first byte of reply is 0XFF , then it is STOR MODE {STOR MODE 2 HI 1 M 0 LOW Transmit the read-command 00,00,0f READ data READ INFO 11 10 9 8 7 6 5 4 3 2 1 0 Alam H Alam L fs unit S M H d m m y Samprate BLOCKBUF 512 Except the last time, It is sent BLOCKBUF real data 2 hi 1 lo 0 0x0f Hi*256+lo is the times of reading data //STOR MODE } If it not 0XFF, then it is REAL MODE STATUS 7 6 5 4 3 2 1 0 Auto:0 Manual:1 RT/STOR check 1dBA 0dBC 11fast 0slow Samprate SAMPRATE =0 this means EMS memory is empty “serial parameters” To connect to the device via USB, you will need to know the following for development.. VID : VID_10C4 PID : PID_0003 Baud rate : (9600) Bit value : 8
Notes
TBD
Python script
Here's a quick Python script for getting the values out of the EXTECH 407760. A sigrok driver will follow soon.
#!/bin/python
import usb.core import sys dev = usb.core.find(idVendor=0x10c4, idProduct=0xea61)
- dev.baudrate=9600
dev.set_configuration() dev.reset()
bytes_written = dev.write(0x02, [0x00,0x00,0x0D], 0) print "_dbg bytes_written: ", bytes_written
for x in xrange(0,100):
print "_dbg attempting read for the %d time\n" % x try: data = dev.read(0x82, 1,0,1000) if data: print "Data found!\n" sys.exit() else: print "Data not found!\n" except: pass
Example output:
TBD
Resources
TODO.