Gossen Metrawatt Metrahit 16I
Revision as of 17:49, 2 November 2013 by Matthias Heidbrink (talk | contribs) (→Measurement functions and ranges)
Status | in progress |
---|---|
Counts | 3100 (31000) |
IEC 61010-1 | CAT III 1000 V, CAT IV 600 V |
Connectivity | Infrared (RS232) |
Measurements | voltage, current, resistance, capacitance, temperature, diode, continuity |
Features | autorange, data hold, bargraph |
Website | [1] |
The Gossen Metrawatt Metrahit 16I is a 3100 counts handheld digital multimeter with IR (RS232) connectivity and insulation measurement (500/1000 V).
The resolution is one digit higher on the data interface.
Hardware
- Fuse: None!
- TODO.
Photos
Measurement functions and ranges
Measurement function | Range | Resolution | Deviation | sigriok result | Remarks |
---|---|---|---|---|---|
V= | 30 mV | 10 μV | ±(0,5% + 3) | sigrok result | Not covered by autorange, use manual range |
300 mV | 100 μV | ±(0,5% + 3) | Not covered by autorange, use manual range | ||
3 V | 1 mV | ±(0,25% + 1) | |||
30 V | 10 mV | ||||
300 V | 100 mV | ||||
600 V | 1 V | ±(0,35% + 1) | |||
V≈ | 3 V | 100 μV | ±(1.0% + 3) (> 10 Digit) | ||
30 V | 100 μV | ||||
300 V | 1 mV | ||||
1000 V | 10 mV | ||||
V≃ | 3 V | 100 μV | ±(1.0% + 3) (> 10 Digit) | ||
30 V | 100 μV | ||||
300 V | 1 mV | ||||
1000 V | 10 mV | ||||
A≈ (Clamp only) | 30 A | 10 mA | ±(2,5% + 3) (>10 Digit) | Current clamp with 100 mV/A required, e.g. GMC WZ12B | |
100 A | 100 mA | ||||
Ω | 30.00 Ω | 10 mΩ | ±(0,5% + 3) | ||
300.0 Ω | 100 mΩ | ||||
3.000 kΩ | 1 Ω | ±(0,4% + 1) | |||
30.00 kΩ | 10 Ω | ||||
300.0 kΩ | 100 Ω | ||||
3.000 MΩ | 1 kΩ | ±(0,6% + 1) | |||
30.00 MΩ | 10 kΩ | ±(2,0% + 1) | |||
Diode/Cont. | 3.0000 V– | 1 mV | ±(0,25% + 1) | ||
Cap. F | 30.00 nF | 10 pF | ±(1,0% + 3) | ||
300.0 nF | 100 pF | ||||
3.000 µF | 1 nF | ||||
30.00 µF | 10 nF | ±(3,0% + 3) | |||
Hz | 300.00 Hz | 0.01 Hz | ±(0.1% + 3) | ||
3.0000 kHz | 0.1 Hz | ||||
30.000 kHz | 1 Hz | ||||
100.000 kHz | 10 Hz | ||||
°C | Pt100 | –200.0 - +200.0 °C | 2 Kelvin + 5 | ||
+200.0 - +800.0 °C | ±(1.0% + 5) | ||||
Pt1000 | –100.0 - +200.0 °C | 2 Kelvin + 5 | |||
+200.0 - +800.0 °C | ±(1.0% + 5) | ||||
Event count | |||||
Stop Watch |