Difference between revisions of "Gossen Metrawatt Metrahit 27I"

From sigrok
Jump to navigation Jump to search
Line 2: Line 2:
| image          = <!-- [[File:Siemens B1105 small.png|180px]] -->
| image          = <!-- [[File:Siemens B1105 small.png|180px]] -->
| name            = Gossen Metrawatt 27I
| name            = Gossen Metrawatt 27I
| status          = planned
| status          = in progress
| source_code_dir = gmc_mh_1x_2x
| source_code_dir = gmc_mh_1x_2x
| counts          = 31000
| counts          = 31000
Line 14: Line 14:
'''Please note: This page is a work in progress and still partly incorrect.'''
'''Please note: This page is a work in progress and still partly incorrect.'''


The '''[[Gossen Metrawatt]] Metrahit 27I''' is a 3100/31000 counts 600 V CAT II handheld digital multimeter with IR (RS232/USB) connectivity. It supports milliohm and insulation (megaohm) measurements and has data logging capabilities.
The '''[[Gossen Metrawatt]] Metrahit 27I''' is a 3100/31000 counts 600 V CAT II handheld digital multimeter with bidirectional IR (RS232/USB) connectivity. It supports milliohm and insulation (megaohm) measurements and has data logging capabilities.


There are two versions of this device, an older one with yellow rotary switch and a newer one with red rotary switch. They also have different power supply connectors.
There are two versions of this device, an older one with yellow rotary switch and a newer one with red rotary switch. They also have different power supply connectors.
Line 47: Line 47:
The device has got a device address that can be set to values from 0 to 15 in the setup. Using the device address 15 is recommended if only a single device is used, it sets a special mode with simplified addressing. The device address 0 sets a special mode where the multimeter does not send replies. It cannot be used with sigrok.  
The device has got a device address that can be set to values from 0 to 15 in the setup. Using the device address 15 is recommended if only a single device is used, it sets a special mode with simplified addressing. The device address 0 sets a special mode where the multimeter does not send replies. It cannot be used with sigrok.  


If several devices of the Metrahit 27x family are used on the same RS232 interface using cascaded ''RS232'' interfaces, they need to be set to different device addresses from 1 to 15. In opposite to what the manual says, it seems that the device address 15 can be used, too. This feature is untested.
If several devices of the Metrahit 27x family are used on the same RS232 interface using cascaded ''RS232'' interfaces, they need to be set to different device addresses from 1 to 15. In opposite to what the manual says, it seems that the device address 15 can be used, too. Using several devices on the same RS232 interface is an untested feature.


Please contact [[User:Matthias Heidbrink | Matthias']] if you can test one of the untested features.
Please contact [[User:Matthias Heidbrink | Matthias']] if you can test one of the untested features.
Line 286: Line 286:
|   
|   
|  
|  
| style="background: #ff0000; "| mqflags += HOLD
| mqflags += HOLD
| ?
|  
   
   
|-
|-
Line 294: Line 294:
|   
|   
|  
|  
| style="background: #ff0000; "| mqflags += MIN
| mqflags += MIN
| ?
|  
   
   
|-
|-
Line 302: Line 302:
|   
|   
|  
|  
| style="background: #ff0000; "| mqflags += MAX  
| mqflags += MAX  
| ?
|  


|-
|-
Line 314: Line 314:
[[Category:Device]]
[[Category:Device]]
[[Category:Multimeter]]
[[Category:Multimeter]]
[[Category:Planned]]
[[Category:In progress]]

Revision as of 11:17, 31 May 2014

Gossen Metrawatt 27I
Status in progress
Source code gmc_mh_1x_2x
Counts 31000
IEC 61010-1 CAT II 600 V
Connectivity Infrared (RS232/USB)
Measurements voltage, resistance, temperature, diode, continuity
Features autorange, data hold, backlight, insulation measurement, data logging
Website [1]

Please note: This page is a work in progress and still partly incorrect.

The Gossen Metrawatt Metrahit 27I is a 3100/31000 counts 600 V CAT II handheld digital multimeter with bidirectional IR (RS232/USB) connectivity. It supports milliohm and insulation (megaohm) measurements and has data logging capabilities.

There are two versions of this device, an older one with yellow rotary switch and a newer one with red rotary switch. They also have different power supply connectors.

Hardware

  • Power supply:
    • Battery: 3x 1,2 V NiMH rechargeable batteries
    • External power supply NA HIT 27 (Art. Z218J) by Gossen Metrawatt, 5V, 600 mA (newer version)
  • Fuse:
    • FF (UR) 1,6 A/1000 V AC/DC (10 kA) 6,3 mm x 32 mm

Photos

Communication Protocol

The complete description is available on request from the manufacturer.


Measurement functions and ranges

Measurement function Range Resolution Accuracy sigrok result Remarks
V= 3 V 100 μV ±(0.1% + 10) mq V, unit V, mqflags DC
30 V 1 mV ±(0.1% + 5) "
300 V 10 mV "
600 V 100 mV "
V≈ 3 V 100 μV ±(0.2% + 10) mq V, unit V, mqflags AC
30 V 1 mV "
300 V 10 mV "
600 V 100 mV "
mΩ@1A 3 mΩ 0.001 mΩ ±(1% + 10) mq Res., unit Ω, mqflags - 4-wire Kelvin measurement
30 mΩ 0.001 mΩ ±(0.5% + 10) " "
300 mΩ 0.01 mΩ " "
mΩ@200 mA 30 mΩ 0.01 mΩ ±(0.25% + 10) " "
300 mΩ 0.01 mΩ " "
3 Ω 0.1 mΩ " "
30 Ω 1 mΩ " "
Ω 300.00 Ω 1 mΩ ±(0.1% + 10) " ZERO with yellow button
3.0000 kΩ 10 mΩ ±(0.1% + 5) " "
30.000 kΩ 100 mΩ "
300.00 kΩ 1 Ω "
3.0000 MΩ 10 Ω "
30.000 MΩ 100 Ω ±(1.5% + 10) "
MΩ (Insulation) 30 MΩ 10 kΩ ±(2% + 10) " Insulation measurement, test voltage selectable 50/100/250/500 V
300 MΩ 100 kΩ " "
3 GΩ 1 MΩ ±(2% + 10) " "
Cont. 310 Ω 100 mΩ ±(1% + 5) mq Res., unit Ω, mqflags - Signal < about 10 Ω
Diode 3 V 100 µV ±(1% + 5) mq V, unit V, mqflags DC,DIODE
Hz 300.00 Hz 0.01 Hz ±(0.05% + 5) mq Freq., unit Hz, mqflags AC
3.000 kHz 0.1 Hz "
°C Pt100/Pt1000
–200.0 - +100.0 °C
0.1 °C ±(1 K + 5) mq Temp., unit °C, mqflags -
Pt100/Pt1000
+100.0 - 850.0 °C
±(0.5% + 5) "
Ni 100/Ni1000
-60-+180 °C
" Not tested yet due to lack of corresponding sensor.
°F " " " mq Temp., unit °F, mqflags - Details and ranges like °C.
Data Hold mqflags += HOLD
MIN mqflags += MIN
MAX mqflags += MAX

The Accuracy row was simplified, see manual for exact specs.

The column "sigrok result" contains in short form what the driver generates for the resp. data type.