Difference between revisions of "Motech LPS-300 series"
m (→Commands) |
m |
||
Line 2: | Line 2: | ||
| image = [[File:Motech_LPS-301_logo.png|180px]] | | image = [[File:Motech_LPS-301_logo.png|180px]] | ||
| name = Motech LPS-300 series | | name = Motech LPS-300 series | ||
| status = | | status = in progress | ||
| source_code_dir = | | source_code_dir = | ||
| channels = 1/3 | | channels = 1/3 | ||
Line 27: | Line 27: | ||
! Channels | ! Channels | ||
! Voltage/Current | ! Voltage/Current | ||
! sigrok status | |||
|- | |- | ||
Line 33: | Line 34: | ||
| 1 | | 1 | ||
| 30 V/1 A or 15 V/2 A | | 30 V/1 A or 15 V/2 A | ||
| Supported | |||
|- | |- | ||
Line 39: | Line 41: | ||
| 1 | | 1 | ||
| 30 V/2 A or 15 V/4 A | | 30 V/2 A or 15 V/4 A | ||
| Planned | |||
|- | |- | ||
Line 45: | Line 48: | ||
| 1 | | 1 | ||
| 30 V/3 A | | 30 V/3 A | ||
| Planned | |||
|- | |- | ||
Line 51: | Line 55: | ||
| 3 | | 3 | ||
| ±30 V/1 A or ±15 V/2 A; 5 V/2 A | | ±30 V/1 A or ±15 V/2 A; 5 V/2 A | ||
| Planned | |||
|- | |- | ||
Line 57: | Line 62: | ||
| 3 | | 3 | ||
| ±30 V/2.5 A; 3.3 or 5 V/3 A | | ±30 V/2.5 A; 3.3 or 5 V/3 A | ||
| Planned | |||
|} | |} | ||
The three-channel versions have the two main channels wired together for symmetric power supply, but the voltages can be set independantly, if desired. They can be set on or off only together. | The three-channel versions have the two main channels wired together for symmetric power supply, but the voltages can be set independantly, if desired. They can be set on or off only together. | ||
The ''planned'' models are prepared in the driver ''moptecl-lps-30x'' and can be implemented easily as soon as devices for testing are available. | |||
These specifications are common to all models: | These specifications are common to all models: | ||
Line 272: | Line 280: | ||
[[Category:Power supply]] | [[Category:Power supply]] | ||
[[Category: | [[Category:In progress]] |
Revision as of 21:46, 19 May 2014
The Motech LPS-300 series of programmable power supplies consists of 5 1-channel or 3-channel devices with optional RS232 connectivity.
The devices were also sold as Amrel LPS-301 to LPS-305 by American Reliance and partly under further brands, e.g. the LPS-305 as Tecpel TPS-3025.
Specifications
The models differ only in the number of available channels, maximum voltage and maximum current output:
Model | Power Output | Channels | Voltage/Current | sigrok status |
---|---|---|---|---|
LPS-301 | 30 W | 1 | 30 V/1 A or 15 V/2 A | Supported |
LPS-302 | 60 W | 1 | 30 V/2 A or 15 V/4 A | Planned |
LPS-303 | 90 W | 1 | 30 V/3 A | Planned |
LPS-304 | 70 W | 3 | ±30 V/1 A or ±15 V/2 A; 5 V/2 A | Planned |
LPS-305 | 165 W | 3 | ±30 V/2.5 A; 3.3 or 5 V/3 A | Planned |
The three-channel versions have the two main channels wired together for symmetric power supply, but the voltages can be set independantly, if desired. They can be set on or off only together.
The planned models are prepared in the driver moptecl-lps-30x and can be implemented easily as soon as devices for testing are available.
These specifications are common to all models:
30 V Channels | ||
---|---|---|
Voltage | Current | |
Programming Resolution | 10 mV | 1 mA |
Programming Accuracy | 0.05% + 20 mV | 0.15% + 5 mA |
Readback Accuracy | 0.1% + 20 mV | 0.2% + 5 mA |
Ripple (10 Hz to 20 MHz) | 1 mV rms / 10 mV p-p | 10 mA rms |
Load Regulation | 0.001% + 1mV | 0.01% + 1mA |
These specifications apply only to models having a 3.3V/5V output:
3.3/5V Channel | ||
---|---|---|
Voltage | Current | |
Ripple (10Hz to 20MHz) | 2 mVrms / 10mVp-p | 10mArms |
Load Regulation | 0.001% + 1mV | 0.01% + 1mA |
The devices can be calibrated easily requiring nothing but a multimeter of sufficient precision.
Protocol
The communication with the device is via an optional RS-232 port (Option 02). The port parameters are 2400 Baud, 8n1.
All commands are plain ASCII. All commands are terminated by \r, \n or \r\n. Another command sent before reception of the reply (usually OK) will be ignored. It seems that trailing digits for numerical parameters can be left away.
Commend | Reply | Description |
---|---|---|
BEEP(0|1|2|3) | OK | Beeper function 0: disable; 1: enable; 2: force alarm (beeper test) 3: end force alarm. |
CALI(0|1|2) | ? | Calibration 0=end; 1=begin; 2=input parameter There seem to be no plausibility checks and the description is incomplete. Messing around with the calibration is strictly discouraged and can cause odd behaviour! |
HELP | (see right) OK | Output list of commands (several lines) |
IOUT(n) | d.dddd OK | Current readback |
ISET(n) d.dddd | OK | Set output current |
LOWA(0|1) | OK | CC output compensated 0=off; 1=on (what does this setting do?) |
MODEL | \r\nLPS-␣␣␣␣ OK | Get model number (reply contains spaces instead of model no in FW 1.17, seems to be a bug) |
OUT(0|1) | OK | Disable/enable output. OUT without a parameter seems to disable it. |
STATUS | <decimal> OK | Working status, bitwise encoding. Bit 0, channel 1 mode: 0: CV 1: CC. Bit 1, channel 2 mode: 0: CV 1: CC. Bit 3,2, tracking: 00: independant; 10: to channel 1; 11: to channel 2. Bit 4, digital output 3: 0: off; 1: on. Bit 5, digital output voltage: 0: 5 V; 1: 3.3 V. Bit 6, output 1/2: off; 1: on. Bit 7, output 3: 0: ok; 1: overloaded. Bit 8, Fan: 0: off/low; 1: on/high Bit 9, beeper: 0: disabled; 1: enabled. Corresponds to BEEP0/1. Bit 10, CC output compensated: 0: off; 1: on |
TRACK(0|1|2) | OK | Tracking 0=independant; 1=from channel 1; 2=from channel 2. Tracking seems to mean that channels 1 and 2 are synchronous on multi-channel models. |
VDD(0|3|5) | OK | Set ("digital") output 3 0=off; 1=3.3 V; 5=5 V |
VERSION | \r\nVer-1.17␣\r\n OK | Get version number. Bug: Seems not to work during output is active on LPS-301 1.17, no reply! |
VOUT(1|2) | dd.ddd OK | Voltage readback |
VSET(1|2) dd.ddd | OK | Set output voltage. Entering more than 3 post-dot digits will overwrite starting from the left! The specified resolution is 10 mV. However, the actual resolution seems to be slightly higher, possibly due to rounding during decimal to binary conversion or depending on calibration. |
* | \r\nERROR\r\n OK | Error (invalid command). |
OK means \r\nOK\r\n.
Commands
Function | Target | Parameters | Comment |
---|---|---|---|
SR_CONF_OUTPUT_CHANNEL | Device | String Independent | Track1 | Track2 | In tracking mode the other main channel seems to follow the tracked channel. |
SR_CONF_OUTPUT_VOLTAGE | Channel | Double 0-30.0 | Get: Query output voltage. Updated only if sampling is active! Channel 3 allows only 5 V or 3.3 and 5 V, depending on model! |
SR_CONF_OUTPUT_VOLTAGE_MAX | Channel | Double 0-30.0 | Get: Get max. possible voltage. Set: Set output voltage. Channel 3 allows only 5 V or 3.3 and 5 V, depending on model! |
SR_CONF_OUTPUT_CURRENT | Channel | Double 0.005-x.xxxx | Get: Query output current. Updated only if sampling is active! Channel 1 and 2 only, channel 3 is fixed! |
SR_CONF_OUTPUT_CURRENT_MAX | Channel | Double 0.005-x.xxxx | Get: Get max. possible current. Set: Set output current. Channel 1 and 2 only, channel 3 is fixed! |
SR_CONF_OUTPUT_ENABLED | Channel | Boolean on/off | Switch output on or off. Channels 1 and 2 are connected, accessing one will also set the other one. |
Additionally sampling commands are possible.