Difference between revisions of "Voltcraft 18220"
Jump to navigation
Jump to search
m (Category) |
m (Additions.) |
||
Line 33: | Line 33: | ||
= Manual Operation = | = Manual Operation = | ||
== Status on power up == | == Status on power up == | ||
The output is disabled. Voltage and current are set to the value on previous power-off. | The output is disabled. Voltage and current are set to the value on previous power-off. A small negative (!) voltage can be measured while output is off. | ||
== Output Control == | == Output Control == | ||
Line 53: | Line 53: | ||
The sigrok driver for this device will be named ''voltcraft-18220''. | The sigrok driver for this device will be named ''voltcraft-18220''. | ||
= Resources = | = Resources = | ||
* Manual (German) available from Conrad Elektronik via customer support. | * Manual (German) available from [http://www.conrad.de Conrad Elektronik] via customer support. | ||
= See also = | = See also = |
Revision as of 19:04, 23 February 2014
Status | in progress |
---|---|
Channels | 1 |
Voltage/current (CH1) | 0-40V / 0-5A |
Connectivity | RS232 |
Features | settable values, settable output. |
Please note: This page is a work in progress, more to come.
The Conrad Voltcraft 18220 is a one-channel digitally-controlled laboratory power supply with RS-232 connectivity. It came onto the market in about 1996. It was sold by Conrad Elektronik as article 512923.
Hardware
- Output protection against reverse current: Max. 1 A!
Photos
Protocol
ASCII based.
Manual Operation
Status on power up
The output is disabled. Voltage and current are set to the value on previous power-off. A small negative (!) voltage can be measured while output is off.
Output Control
- On: Keep button VOLT/AMPERE pressed, press ▲.
- Off: Keep button VOLT/AMPERE pressed, press ▼.
Voltage Control
- If LED Volt is not on, press button VOLT/AMPERE.
- Press ▲ to increase voltage by 50 mV.
- Press ▼ to decrease voltage by 50 mV.
Current Control
- If LED AMPERE is not on, press button VOLT/AMPERE.
- Press ▲ to increase current limit by 100 mA.
- Press ▼ to decrease current limit by 100 mA.
- To display current current limit, shorten output externally.
Remote Operation
The sigrok driver for this device will be named voltcraft-18220.
Resources
- Manual (German) available from Conrad Elektronik via customer support.