Difference between revisions of "Gossen Metrawatt Metrahit 14A"

From sigrok
Jump to navigation Jump to search
(Created page.)
 
(→‎Measurement functions and ranges: Removed amps ranges that could not be found in device.)
Line 59: Line 59:
| rowspan="2" | ±(1,0% + 3)
| rowspan="2" | ±(1,0% + 3)
| mq V, unit V, mqflags DC
| mq V, unit V, mqflags DC
|  
| Manual range


|-
|-
Line 65: Line 65:
| 100 μV
| 100 μV
| "
| "
|  
| "


|-
|-
Line 120: Line 120:


|-
|-
| rowspan="5" | A=
| rowspan="3" | A=
| 3.000 mA
| 1 µA
|
| mq Curr., unit A, mqflags DC
|
 
|-
| 30.00 mA
| 30.00 mA
| 10 µA
| 10 µA
|  
|  
| "
| mq Curr., unit A, mqflags DC
|  
|  


Line 137: Line 130:
| 300.0 mA
| 300.0 mA
| 100 µA
| 100 µA
|
| "
|
|-
| 3.000 A
| 1 mA
|  
|  
| "
| "
Line 156: Line 142:


|-
|-
| rowspan="4" | A≈
| rowspan="3" | A≈
| 30.00 mA
| 30.00 mA
| 10 µA
| 10 µA
Line 169: Line 155:
| "
| "
|  
|  
|-
| 3.000 A
| 100 µA
|
| "
| ?


|-
|-

Revision as of 19:37, 2 January 2014

Gossen Metrawatt Metrahit 14A
Status progress
Source code gmx_mh_1x_2x
Counts 3100
IEC 61010-1 CAT III 1000 V, CAT IV 600 V
Connectivity Infrared (RS232)
Measurements voltage, current, resistance, capacitance, temperature, diode, continuity
Features autorange, data hold, bargraph

The Gossen Metrawatt Metrahit 14A is a 3100 counts handheld digital multimeter with IR (RS232) connectivity.

It is very similar to the Metrahit 14S, but has no ranges of 3 µA= and 3 mA≈.

This page is a work in progress, information incomplete and possibly inaccurate!


Measurement functions and ranges

Measurement function Range Resolution Accuracy sigrok result Remarks
V= 30.00 mV 10 μV ±(1,0% + 3) mq V, unit V, mqflags DC Manual range
300.0 mV 100 μV " "
3.000 V 1 mV ±(0,15% + 1) "
30.00 V 10 mV "
300.0 V 100 mV "
1000 V 1 V ±(0,2% + 1) "
V≈ 3.000 V 100 μV ±(0,4% + 2) "
30.00 V 100 μV "
300.0 V 1 mV "
1000 V 10 mV "
A= 30.00 mA 10 µA mq Curr., unit A, mqflags DC
300.0 mA 100 µA "
10.00 A 10 mA "
A≈ 30.00 mA 10 µA mq Curr., unit A, mqflags AC,DC,RMS
300.0 mA 100 µA "
10.00 A 10 mA "
Ω 30.00 Ω 10 mΩ mq Res., unit Ω, mqflags -
300 Ω 100 mΩ "
3.000 kΩ 100 mΩ "
30.00 kΩ 1 Ω "
300.0 kΩ 10 Ω "
3.000 MΩ 100 Ω "
30.00 MΩ 1 kΩ "
Diode/Cont. 3.000 V– 1 mV mq V, unit V, mqflags DC,DIODE Diode and cont. are identical on this device, just without beeper for diode.
°C Pt100 –200.0 - +200.0 °C 0.1 °C 2 Kelvin + 5 mq Temp., unit °C, mqflags -
Pt100 +200.0 - +850.0 °C ±(1.0% + 5) "
Pt1000 –100.0 - +200.0 °C 2 Kelvin + 2 "
Pt1000 +200.0 - +850.0 °C ±(1.0% + 2) "
Data Hold mqflags += HOLD Disabled while IR interface is active.
MIN mqflags += MIN Influences only display, via IR flag is set, but actual current value is delivered.
MAX mqflags += MAX Influences only display, via IR flag is set, but actual current value is delivered.

The column "sigrok result" contains in short form what the driver generates for the resp. data type.