Difference between revisions of "Gossen Metrawatt Metrahit 16I"

From sigrok
Jump to navigation Jump to search
m
Line 38: Line 38:
</gallery>
</gallery>
-->
-->
== Measurement functions and ranges ==
The following table is a work in progress and currently inaccurate!
{|border="0" style="font-size: smaller" class="alternategrey sortable sigroktable"
|-
! Measurement function
! Range
! Resolution
! Error
! Remarks
|-
| rowspan="6" | V=
| 30 mV
| 10 μV
| ±(0,5% + 3)
| Not within autorange, use manual range
|-
| 300 mV
| 100 μV
| ±(0,5% + 3)
| Not within autorange, use manual range
|-
| 3 V
| 1 mV
| rowspan="3" | ±(0,25% + 1)
|
|-
| 30 V
| 10 mV
|
|-
| 300 V
| 100 mV
|
|-
| 600 V
| 1 V
| ±(0,35% + 1)
|
|-
| rowspan="4" | V≈
| 3 V
| 100 μV
| rowspan="4" | ±(0,5% + 30) (> 300 Digit)
|
|-
| 30 V
| 100 μV
|
|-
| 300 V
| 1 mV
|
|-
| 1000 V
| 10 mV
|
|-
| rowspan="4" | V≃
| 3 V
| 100 μV
| rowspan="4" | ±(0,5% + 30) (> 300 Digit)
|
|-
| 30 V
| 100 μV
|
|-
| 300 V
| 1 mV
|
|-
| 1000 V
| 10 mV
|
|-
| rowspan="2" | A≈ (Clamp only)
| 30 A
| 10 mA
|
| rowspan="2" | Current clamp with 100 mV/A required, e.g. GMC WZ12B
|-
| 100 A
| 100 mA
|
|-
| rowspan="7" | Ω
| 30.00 Ω
| 10 mΩ
|
|
|-
| 300.0 Ω
| 100 mΩ
|
|
|-
| 3.000 kΩ
| 1 Ω
|
|
|-
| 30.00 kΩ
| 10 Ω
|
|
|-
| 300.0 kΩ
| 100 Ω
|
|
|-
| 3.000 MΩ
| 1 kΩ
|
|
|-
| 30.00 MΩ
| 10 kΩ
|
|
|-
| Diode/Cont.
| 3.0000 V–
| 1 mV
|
|
|-
| rowspan="4" | Cap. F
| 30.00 nF
| 10 pF
|
|
|-
| 300.0 nF
| 100 pF
|
|
|-
| 3.000 µF
| 1 nF
|
|
|-
| 30.00 µF
| 10 nF
|
|
|-
| rowspan="4" | Hz
| 300.00 Hz
| 0.01 Hz
| rowspan="4" | ±(0.1% + 3)
|
|-
| 3.0000 kHz
| 0.1 Hz
|
|-
| 30.000 kHz
| 1 Hz
|
|-
| 100.000 kHz
| 10 Hz
|
|-
| rowspan="4" | °C
| rowspan="2" | Pt100
| –200.0 - +100.0 °C
| rowspan="4" | 0.1 °C
| rowspan="4" | 0,5 °C + 3
|-
| +100.0 - +850.0 °C
|-
| rowspan="2" | Pt1000
| –100.0 - +100.0 °C
|-
| +100.0 - +850.0 °C
|-
| Event count 
|
|
|-
| Stop Watch 
|
|
|-
|}


[[Category:Device]]
[[Category:Device]]
[[Category:Multimeter]]
[[Category:Multimeter]]
[[Category:In progress]]
[[Category:In progress]]

Revision as of 23:47, 1 November 2013

Gossen Metrawatt Metrahit 16I
Status in progress
Counts 3100 (31000)
IEC 61010-1 CAT III 1000 V, CAT IV 600 V
Connectivity Infrared (RS232)
Measurements voltage, current, resistance, capacitance, temperature, diode, continuity
Features autorange, data hold, bargraph
Website [1]

The Gossen Metrawatt Metrahit 16I is a 3100 counts handheld digital multimeter with IR (RS232) connectivity and insulation measurement (500/1000 V).

The resolution is one digit higher on the data interface.

Hardware

  • Fuse: None!
  • TODO.

Photos

Measurement functions and ranges

The following table is a work in progress and currently inaccurate!

Measurement function Range Resolution Error Remarks
V= 30 mV 10 μV ±(0,5% + 3) Not within autorange, use manual range
300 mV 100 μV ±(0,5% + 3) Not within autorange, use manual range
3 V 1 mV ±(0,25% + 1)
30 V 10 mV
300 V 100 mV
600 V 1 V ±(0,35% + 1)
V≈ 3 V 100 μV ±(0,5% + 30) (> 300 Digit)
30 V 100 μV
300 V 1 mV
1000 V 10 mV
V≃ 3 V 100 μV ±(0,5% + 30) (> 300 Digit)
30 V 100 μV
300 V 1 mV
1000 V 10 mV
A≈ (Clamp only)  30 A 10 mA Current clamp with 100 mV/A required, e.g. GMC WZ12B
100 A 100 mA
Ω 30.00 Ω 10 mΩ
300.0 Ω 100 mΩ
3.000 kΩ 1 Ω
30.00 kΩ 10 Ω
300.0 kΩ 100 Ω
3.000 MΩ 1 kΩ
30.00 MΩ 10 kΩ
Diode/Cont. 3.0000 V– 1 mV
Cap. F 30.00 nF 10 pF
300.0 nF 100 pF
3.000 µF 1 nF
30.00 µF 10 nF
Hz 300.00 Hz 0.01 Hz ±(0.1% + 3)
3.0000 kHz 0.1 Hz
30.000 kHz 1 Hz
100.000 kHz 10 Hz
°C Pt100 –200.0 - +100.0 °C 0.1 °C 0,5 °C + 3
+100.0 - +850.0 °C
Pt1000 –100.0 - +100.0 °C
+100.0 - +850.0 °C
Event count
Stop Watch